Aircon Drainage Repair in Singapore

Water from the indoor unit always looks the same — but the cause varies. Blocked drain, cracked pan, slope problem, or disconnected pipe. The fix depends on which one.

What Is Drainage Repair

A systematic trace of the full condensate path — from the drain pan inside the indoor unit, through the drain line, to the discharge point. We identify the root cause before recommending any fix, and check every section of the run, not just the visible blockage.

Common Drainage Faults

Most water leak complaints trace back to one of these. We check all of them systematically.

  • Blocked condensate drain

    The most common cause. Dust, algae, and slime accumulate in the drain line over time, restricting flow until water backs up and overflows from the drain pan.

  • Cracked drain pan

    The plastic pan beneath the evaporator coil cracks from age or thermal stress. Water bypasses the drain line entirely and drips from the unit body.

  • Incorrect drainage slope

    Condensate drains rely on gravity. Insufficient slope — or a reverse gradient — causes water to pool in the line instead of flowing to the discharge point.

  • Disconnected or misaligned pipe

    Drain pipes that have shifted or come loose exit water at the wrong point instead of reaching the discharge outlet.

  • Algae and slime buildup

    Biological growth restricts flow even without a full blockage. Common in Singapore's humidity, especially in units that run infrequently.

How We Fix It

We do not just clear the visible blockage — we trace the full run and fix the root cause.

  1. 01

    Trace the drainage path

    From drain pan to discharge point — every section checked for blockages, cracks, slope issues, and connection integrity.

  2. 02

    Identify the fault

    Blockage, crack, slope problem, or connection issue — sometimes more than one. The fix depends on the root cause.

  3. 03

    Fix the root cause

    Drain clearing for blockages. Pan replacement for cracks. Slope correction for gradient issues. Pipe rerouting for misaligned runs.

  4. 04

    Test and verify

    Water run through the full path to confirm flow from pan to discharge — no drips, no pooling, no slow drainage.

Benefits of Drainage Repair

What changes after the root cause is fixed.

  • Full path traced, not just the visible blockage

    Pan to discharge point, every section checked before the fix is recommended.

  • Root cause fixed, not the symptom

    Clearing a blockage when the real issue is slope or a cracked pan just means it returns.

  • Most repairs completed same visit

    Common parts like drain pans and fittings carried on every van.

  • Water damage prevented

    Drainage faults left unaddressed cause ceiling staining, mould, and structural damage over time.

When to Book Drainage Repair

Water near an aircon unit can have several causes. These point specifically to a drainage fault.

  • Water dripping from the indoor unit

    The most common sign of a blocked or damaged drainage path.

  • Ceiling staining near the air outlet

    Condensate backing up, not necessarily a structural leak.

  • Leak returns after servicing

    A drain flush clears simple blockages but does not fix slope, cracks, or disconnected pipes.

  • Musty smell from the unit

    Stagnant water in a blocked drain pan promotes mould growth.

  • Post-renovation

    Construction dust accumulates in drain lines and needs clearing before regular use.

When Drainage Repair Is Not the Right Call

Not all water near an aircon unit is a drainage fault.

  • Condensation on the unit body

    Usually an insulation issue, not a drain fault.

  • Ice on the evaporator that melts and drips

    Typically a refrigerant or airflow issue, not drainage.

  • Water from the outdoor unit

    Normal condensation during cooling, not a fault.

  • Dripping only in very high humidity

    May be surface condensation rather than a drainage problem.

Drainage Repair FAQ

Drainage Repair Rates

Assessment fee waived if you proceed with the repair. We cover all areas of Singapore, Monday to Saturday. See the full price list for all services.