Aircon General Servicing in Singapore

Routine clean of four buildup areas — filters, coil, drain, and blower. The question is whether the unit is due for a standard rinse or whether the buildup has already gone deeper.

What Is Aircon General Servicing

Dust and grime accumulate on the filters, coil, drain, and blower every time the unit runs. General servicing clears all four before performance drops.

Service Scope

Filters, coil, drain, blower — plus a condition check.

  • Filter wash

    Filters removed, rinsed clear of dust and debris, dried, and refitted. The main restrictor of airflow when left too long.

  • Evaporator coil rinse

    Coil fins flushed with water to clear surface grime and restore heat exchange. No chemicals — a standard rinse for units in normal condition.

  • Drain line flush

    Condensate drain flushed from the unit to the discharge point to clear early-stage algae before it builds into a blockage.

  • Blower clean

    Fan blades wiped and brushed to remove accumulated dust. Restores airflow volume and reduces vibration noise from an unbalanced blade.

  • Condition check

    We note anything unusual — coil corrosion, bearing noise, refrigerant indicators — and flag it separately. Nothing added without your approval.

Benefits of General Servicing

Four outcomes after every visit.

  • Restored airflow

    Filters and blower cleared so air moves freely again.

  • Cleaner output

    Coil rinse removes surface mould and dust that circulates into the room.

  • Drainage cleared

    Drain line flushed to prevent drip leaks before they start.

  • Condition check

    We flag anything unusual so you know what to watch before it becomes a fault.

When to Book General Servicing

Usage, environment, and what you notice determine whether it's time.

  • Unit is due based on your usage interval

    Every 3 to 4 months for heavy daily use, every 4 to 6 months for moderate use, every 6 months for light use.

  • Mild dust buildup with no smell or weak airflow

    A standard rinse is sufficient, no need to step up.

  • Multiple units on a maintenance schedule

    General servicing at each interval keeps all units consistent.

  • Before peak heat months

    Servicing before June or December prevents performance issues when units run hardest.

  • Post-renovation baseline clean

    Removes construction dust before the unit is used regularly again.

When General Servicing Is Not Suitable

General servicing is a rinse and clean. If your unit has deeper issues, a different service is the better starting point.

  • Smell or weak airflow persists after a recent general service

    Buildup is beyond rinse range, book a chemical wash.

  • Unit powers on but does not cool

    Likely a refrigerant or compressor issue, not a cleaning problem.

  • Error code or blinking light

    Indicates a sensor or control board fault that a clean will not resolve.

  • Loud grinding or buzzing

    Worn motor or fan bearing, a clean will not fix mechanical wear.

  • Water leaking from unusual places

    May be a cracked drain pan, not a simple blockage.

General Servicing FAQ

General Servicing Rates

Tiered pricing by unit count. Rates for all system types. We cover all areas of Singapore, Monday to Saturday. See the full price list for all services.

Service3+21
General servicing (wall-mounted)
General servicing$25$30$50
General servicing (ceiling cassette)
General servicing$30$40$60
General servicing (ducted)
General servicing$30$40$60