On this page
Quick summary
Daikin has the deepest residential parts network in Singapore, so a repair decision turns on the fault and the unit’s age, not on sourcing. Manufacturer cover and installer workmanship are separate, and each model family has its own code table.
Daikin Fault Shortcuts
Use these first if your Daikin unit is already showing a blinking light, error code, or repeat fault.
Which Daikin Series and Registered Model Do You Own?
Daikin's current wall-mounted families are iSmile, iSmileEco+, iSmileEco, EZi and iSmart ENVi. The indoor sticker carries the family code: iSmile uses CTKS and CTKB, iSmileEco+ uses CTKM ZVMG, and iSmileEco uses CTKM and CTKP VVMG. EZi uses CTKC WVMG, while iSmart ENVi uses FTKM XVMG for single-split rooms. The register lists the outdoor unit that pairs with each family, and that code decides the capacity class for the whole home.
The register snapshot from 22 July 2026 lists multi-split outdoor units from the MKM50ZVMG at 4.15 kW to the MKM100ZVMG at 8.62 kW, all rated five ticks. Single-split registrations include the RKM25ZVMG at 2.45 kW and the RKM60ZVMG at 6.03 kW, rated five and four ticks. Older MKS outdoor units belong to earlier installations and do not appear in this snapshot.
Scroll to see more columns
| Registered outdoor model | Type | Cooling (kW) | NEA ticks | Registration expires |
|---|---|---|---|---|
| MKM50ZVMG | Multi split | 4.15 | 5 | 15 Dec 2027 |
| MKM75ZVMG | Multi split | 6.07 | 5 | 12 Dec 2027 |
| MKM100ZVMG | Multi split | 8.62 | 5 | 30 Jan 2028 |
| RKM25ZVMG | Single split | 2.45 | 5 | 30 Jan 2028 |
| RKM35ZVMG | Single split | 3.12 | 5 | 30 Jan 2028 |
| RKM60ZVMG | Single split | 6.03 | 4 | 27 Jan 2028 |
Where the Sticker Sits
The indoor sticker sits along the bottom-right edge behind the front panel, where the CTKS, CTKM, CTKC or FTKM code is printed. The outdoor label faces the wall on most installations, so photograph it before the visit. Send both codes together, because the pair settles parts compatibility.
What Keeps a Daikin Warranty Claim Valid?
Daikin cover depends on how the system entered the home, not only on the purchase date. Three conditions carry weight: an authorised installer commissioned the system, the e-warranty registration was completed, and the servicing file can be produced for the covered period. Product cover comes from the manufacturer, while the installation carries its own workmanship terms.
Registration ties the cover to the purchase record. Servicing receipts answer the question a claim asks about who worked on the unit and when. A regular schedule keeps those receipts easy to produce: filters every 2–4 weeks, general servicing every 3–4 months, and chemical servicing every 12–18 months. The daikin aircon warranty guide sets out how the terms run, so check the paperwork that came with the system before approving any repair.
Keep the model codes on the receipts as well as the dates. A claim moves faster when the registered model, the installed pair and the servicing record all name the same equipment.
Cover questions are worth settling before a technician opens the unit. Once a repair is authorised and parts are ordered, the paperwork position is harder to change.
Multi-split homes should keep the indoor code for every room as well. A claim or a diagnosis that names only the outdoor unit can leave the reporting room unclear.
What Do Daikin Fault Codes Tell You?
Daikin shows alphanumeric codes on the indoor unit, and each one points at a circuit rather than a part. U0 means the system is short of refrigerant, which needs a leak test before any gas top-up. U4 means the indoor and outdoor units have lost transmission, usually along a wiring path or a board connection. A5 points at high-pressure control or freeze-up protection, often after a blocked coil or a fan moving too little air.
A6 covers the fan motor, A3 covers the drain level system, and H6 covers a position detection sensor. The Daikin error-code lookup resolves these rows and the wider residential table, including code combinations the display reports together. Write the code down exactly as shown and note when it appears, because an intermittent code narrows the fault differently from a constant one.
Codes describe what the board sees, not always what failed. A U0 reading can follow a slow leak at a flare joint, and an A5 reading can follow a coil that no longer sheds heat. A pressure test and a coil inspection separate the two before any part is replaced.
What Does Age Change on a Daikin?
Under five years, most faults trace to the installation or a small part. From five to eight years, board and capacitor faults are common, and a compressor failure is where a replacement comparison starts. Past twelve years, a major failure shifts the frame toward replacement, while minor fixes can buy time.
| Age band | Common finding | What to weigh |
|---|---|---|
| Under 5 years | Installation or minor component | Cover and local parts make repair straightforward |
| 5–8 years | Board and capacitor faults | A compressor failure starts the replacement comparison |
| 8–12 years | Sensors and drainage stay repairable | Compressor or inverter-board quotes need comparison |
| Over 12 years | Major component failures | Minor fixes can buy time while planning the changeover |
Which Repair Path Applies
Two paths matter most: PCB replacement once board failure is confirmed, and compressor repair when testing shows the compressor itself has failed. A repair visit establishes which applies before parts are ordered.
For a replacement decision, use the Daikin vs Mitsubishi Electric comparison: Daikin leads on parts availability, Mitsubishi Electric is quieter and more compact indoors. The outdoor code sets the capacity class, so check the registered rating before shortlisting. If the code is over a decade old, check the registration expiry first.