What does Midea EH 60 mean?
Midea EH 60 is listed as indoor room temperature sensor T1 is open circuit or short circuit, indoor room temperature sensor T1 is open or shorted, and indoor room temperature sensor T1 is open circuit or short circuited in Inverter Split, Wall-Mounted Split, Standard Non-Inverter rows such as Midea wall-mounted inverter error-code quick troubleshooting table, Midea Serie Forest ONOFF MSAF / MOBA / MOCA / MOD wall-mounted split systems. This meaning comes from the manufacturer's own diagnostic material. Do not collapse this code across model families; use the model, series, or system type to choose the right row. Confirm the exact model, series, or signal row before accepting a parts quote.
What to do now
Use these steps before customer action, a sensor check, or PCB quote.
Treat it as a fault signal
If EH 60 remains displayed or cooling is still abnormal, preserve the code and arrange diagnosis.
No manufacturer reset steps listed for EH 60
Capture the complete EH 60 pattern and model stickers first. The manufacturer lists no customer reset procedure; do not treat a generic power-cycle as manufacturer guidance.
Send these to us
EH 60 error code and blinking light, a clear display photo and blinking-light video if the unit shows one, Midea model stickers, affected rooms, operating state when the code appeared, and when the fault appears
Choose the listing that matches your unit
The same code has more than one listed meaning. Match the model family, the system type and the unit that shows the code before approving parts.
| Code | What it means | What to check first |
|---|---|---|
| Midea wall-mounted inverter error-code quick troubleshooting table | Indoor room temperature sensor T1 is open circuit or short circuit | Match this meaning to your installed model and the unit that shows the code, then use the checks below. |
| Midea Serie Forest ONOFF MSAF / MOBA / MOCA / MOD wall-mounted split systems | Indoor room temperature sensor T1 is open or shorted | Match this meaning to your installed model and the unit that shows the code, then use the checks below. |
| Midea Xtreme ONOFF R32 MSAGB wall-mounted fixed-speed systems | Indoor room temperature sensor T1 is open circuit or short circuited | Match this meaning to your installed model and the unit that shows the code, then use the checks below. |
- Code
- Midea wall-mounted inverter error-code quick troubleshooting table
- What it means
- Indoor room temperature sensor T1 is open circuit or short circuit
- What to check first
- Match this meaning to your installed model and the unit that shows the code, then use the checks below.
- Code
- Midea Serie Forest ONOFF MSAF / MOBA / MOCA / MOD wall-mounted split systems
- What it means
- Indoor room temperature sensor T1 is open or shorted
- What to check first
- Match this meaning to your installed model and the unit that shows the code, then use the checks below.
- Code
- Midea Xtreme ONOFF R32 MSAGB wall-mounted fixed-speed systems
- What it means
- Indoor room temperature sensor T1 is open circuit or short circuited
- What to check first
- Match this meaning to your installed model and the unit that shows the code, then use the checks below.
Guidance for your model
Notes that match the code to your exact model. Electrical, refrigerant, wiring, resistance and component checks are for a technician.
| Detail | What it says |
|---|---|
| Diagnostic note | Use the source quick-check path: Check the indoor room temperature sensor. |
| Diagnostic note | Use the source quick-check path: Check the T1 sensor connection and resistance before indoor PCB replacement. |
| Diagnostic note | Use the source quick-check path: Check the indoor room sensor connector and resistance before indoor PCB diagnosis. |
| Singapore / model note | Source is an official Midea regional wall-mounted inverter fault table; confirm the exact unit manual if the display differs on a Singapore model. |
| Singapore / model note | Official Midea Forest ONOFF wall-mounted service-manual row. Keep separate from the newer inverter EH / EL / EC / PC rows because fixed-speed models can show compact E/F/P codes. |
| Singapore / model note | Official Midea Xtreme ONOFF wall-mounted service-manual row. Keep separate from the newer inverter and compact Forest ONOFF rows because the source lists this fixed-speed family by EH / EL / EC / PC / PH display codes. |
- Detail
- Diagnostic note
- What it says
- Use the source quick-check path: Check the indoor room temperature sensor.
- Detail
- Diagnostic note
- What it says
- Use the source quick-check path: Check the T1 sensor connection and resistance before indoor PCB replacement.
- Detail
- Diagnostic note
- What it says
- Use the source quick-check path: Check the indoor room sensor connector and resistance before indoor PCB diagnosis.
- Detail
- Singapore / model note
- What it says
- Source is an official Midea regional wall-mounted inverter fault table; confirm the exact unit manual if the display differs on a Singapore model.
- Detail
- Singapore / model note
- What it says
- Official Midea Forest ONOFF wall-mounted service-manual row. Keep separate from the newer inverter EH / EL / EC / PC rows because fixed-speed models can show compact E/F/P codes.
- Detail
- Singapore / model note
- What it says
- Official Midea Xtreme ONOFF wall-mounted service-manual row. Keep separate from the newer inverter and compact Forest ONOFF rows because the source lists this fixed-speed family by EH / EL / EC / PC / PH display codes.
What to check before repair
Use this split to separate safe evidence capture from the tests a technician should prove before quoting parts.
| You can check | Technician should confirm |
|---|---|
| Before taking any system action on EH 60, take a clear display photo and blinking-light video if the unit shows one. | Confirm which sensor EH 60 maps to on the exact model table. |
| Capture the Midea indoor and outdoor model stickers so the correct family row is used. | Measure the sensor value against the service-manual resistance or voltage range. |
| The manufacturer lists no customer reset procedure for this code. Note whether one room, several rooms, or the whole system is affected. | Check connector condition, harness continuity, and PCB input before replacing boards. |
- You can check
- Before taking any system action on EH 60, take a clear display photo and blinking-light video if the unit shows one.
- Technician should confirm
- Confirm which sensor EH 60 maps to on the exact model table.
- You can check
- Capture the Midea indoor and outdoor model stickers so the correct family row is used.
- Technician should confirm
- Measure the sensor value against the service-manual resistance or voltage range.
- You can check
- The manufacturer lists no customer reset procedure for this code. Note whether one room, several rooms, or the whole system is affected.
- Technician should confirm
- Check connector condition, harness continuity, and PCB input before replacing boards.
Sensor or PCB decision
Midea EH 60 is usually repair-first if a sensor or harness reading is confirmed. Board replacement should wait until the sensor circuit is tested.
Sensor replacement is usually targeted when resistance or voltage readings are out of range.
Harness or connector damage can look like a sensor fault until continuity is checked.
PCB replacement is a later step if the sensor and wiring test correctly.
Midea EH 60 questions
What does the Midea EH 60 error mean?
Can I fix a Midea EH 60 error myself?
Is it safe to keep running the aircon with an EH 60 error?
What causes a Midea EH 60 error?
Will a Midea EH 60 error need a repair or a full replacement?
What should I send a technician about a Midea EH 60 error?
Where to go next
Confirm the fault
Share the error code, model number and symptoms so we can assess the likely cause.
Not the right code?
Browse the full Midea list or check a few codes in the same fault category.
Read next
Use these if the quote mentions the parts, checks, or repair path this code points to.