Starmex vs MHI Aircon: Which Mitsubishi Should You Pick?

Starmex is Mitsubishi Electric and MHI is Mitsubishi Heavy Industries: separate companies with separate ranges that cannot be mixed. For a new system, either works if the quote lists an approved indoor and outdoor combination. For one replacement indoor unit, the existing outdoor unit decides.

On this page

Quick summary

Starmex (Mitsubishi Electric) and MHI (Mitsubishi Heavy Industries) are separate companies with separate ranges, and a Starmex indoor unit does not pair with an MHI outdoor unit. For a replacement indoor unit, the existing outdoor model decides the brand. For a new system, compare the same rooms, the same scope and each quote's approved combination.

How to Decide Between the Two

For a new system, either brand is an option when its indoor and outdoor units form a manufacturer-approved combination and the system fits the rooms. Put both quotes on the same rooms and the same installation work.

For a single indoor unit replacement, the outdoor unit's model number settles it. Look the proposed indoor model up in that brand's combination table, because compatibility differs even between ranges from one brand.

  • Models: exact indoor and outdoor model numbers, and the approved combination for the whole system.
  • Capacity: the capacity quoted for each room and how it holds when the rooms run together.
  • Installation: what the price includes for piping, drainage, trunking, electrical work and removal of the old units.
  • Warranty: who handles claims, and what the equipment and workmanship warranties cover.

Two Separate Companies Sharing One Name

Starmex is Mitsubishi Electric's residential aircon range in Singapore. Its R32 split range and combinations are set out in Mitsubishi Electric's own catalogue. MHI is sold through a certified distributor, KM Marketing Pte Ltd. It is a separate R32 range with its own brand-specific pairings.

Each range has its own supported combinations. A Starmex indoor unit and an MHI outdoor unit do not form a supported system. For any replacement, check the combination table for the exact outdoor model.

Two separate companies sharing one name summary table
Decision factorMitsubishi Electric (Starmex)Mitsubishi Heavy Industries (MHI)
Singapore distributorMitsubishi Electric SingaporeKM Marketing Pte Ltd (certified distributor)
Indoor and outdoor mixingPairs only within Starmex combination tablePairs only within MHI combination table
Single indoor unit replacementRequired if existing outdoor unit is StarmexRequired if existing outdoor unit is MHI
Warranty and claim routeHandled through Mitsubishi Electric channelHandled through MHI distributor channel

Which Fits Better for HDB, Condo, and Landed Homes

Neither brand suits a home type better by itself. The decision rests on four things. They are the outdoor unit's space on the ledge and the clearance needed to service it. They also include where each indoor unit can drain and any building restrictions on outdoor placement.

In a large or open-plan room, what matters is how much cooling the system delivers while the other rooms run. Settle pipe and drain routes before comparing installed prices.

Parts Supply and Servicing Network in Singapore

Starmex is published by Mitsubishi Electric Singapore. MHI is sold through the certified distributor KM Marketing Pte Ltd. The two quotes put two different companies behind the warranty and the repair after it. The quote should name which.

On an older system, the exact part or replacement indoor model, its availability and its lead time decide the job. Confirm whether the existing outdoor unit and pipework can stay before committing.

Common Questions

Are Starmex and Mitsubishi Heavy Industries the same company?
Starmex and Mitsubishi Heavy Industries are not the same company. Starmex is Mitsubishi Electric's residential range in Singapore, set out in its own R32 catalogue. Mitsubishi Heavy Industries, or MHI, is sold through its certified distributor, KM Marketing Pte Ltd, and has its own aircon range and supported model combinations.
Which is better for an HDB flat, Starmex or MHI?
Starmex and MHI each suit an HDB flat, because neither brand fits a home type better by itself. The ledge space and service clearance for the outdoor unit, where each indoor unit can drain and any building restrictions on outdoor placement decide the fit, along with how much cooling each system delivers while the usual rooms run together.
Can a Starmex indoor unit run on an MHI outdoor unit?
A Starmex indoor unit cannot run on an MHI outdoor unit, because the two ranges do not form a supported system. For a single indoor unit replacement, look up the existing outdoor model and confirm the proposed indoor model is in that manufacturer's approved combination table, since compatibility differs even between ranges from one brand.
How should a homeowner choose between the two?
A homeowner choosing between Starmex and MHI should give both installers the same list of rooms and ask for the exact indoor and outdoor models in an approved combination. Then compare the installed scope for piping, drainage, trunking and electrical work, capacity under simultaneous use, and which company handles the warranty and repairs.