LG cover names one owner and one installation address and is not transferable. An inherited or moved unit is an uncovered repair unless LG confirms otherwise in writing. The CH code names the circuit at fault. A capacitor or board is often the real cause of what sounds like a compressor failure.
LG Fault Shortcuts
Use these first if your LG unit is already showing a blinking light, error code, or repeat fault.
Which LG Series Is in Your Home?
NEA's register of 22 July 2026 lists twelve LG models, split evenly between single and multi splits. Single-split codes run through the S3UZ, S3UQ and ZUUQ families, and the multi-split range through Z2, Z3 and Z4. ArtCool and ArtCool Mirror are indoor panel designs, so the outdoor code decides the compressor family. Variants within one code use different parts, so read the suffix too.
All registered models fall inside those six code families. A plate carrying anything else belongs to an older generation, and its parts do not follow the current list.
Scroll to see more columns
| Model | Type | Cooling (kW) | Ticks | Registration ends |
|---|---|---|---|---|
| S3UZ091L1DA | Single split | 2.89 | 5 | 2028-06-15 |
| S3UZ121L1DA | Single split | 3.42 | 5 | 2028-05-22 |
| S3UQ12JL1PA | Single split | 3.61 | 4 | 2026-09-18 |
| ZUUQ18GH0 | Single split | 5.48 | 4 | 2028-07-11 |
| ZUUQ21GH0 | Single split | 6.38 | 4 | 2028-07-11 |
| ZUUQ32GH0 | Single split | 8.79 | 4 | 2028-07-11 |
| Z2UQ18GFA1 | Multi split | 4.58 | 5 | 2028-07-13 |
| Z3UQ18GFA0 | Multi split | 5.21 | 5 | 2028-07-03 |
| Z3UQ26GFA0 | Multi split | 6.46 | 5 | 2028-07-03 |
| Z3UQ28GFA1 | Multi split | 6.91 | 5 | 2028-07-13 |
| Z4UQ28GFA0 | Multi split | 7.51 | 5 | 2028-07-03 |
| Z4UQ34GFA1 | Multi split | 7.91 | 5 | 2028-07-10 |
Locating the Label
The outdoor plate sits on the casing beside the pipe connections. Its full suffix decides which replacement part fits. The indoor plate is behind the front panel on the right-hand side. On an ArtCool the fascia unclips first. Lifting the front panel to photograph the indoor plate is safe. The technician reads the outdoor plate, or you take it from the invoice.
Registration and Location Decide LG Cover
LG ties cover to registration soon after purchase, or to proof of purchase when requested. A product with neither is outside the warranty in LG's own wording.
Cover names one owner and one installation location and is not transferable. A unit inherited with a resale flat, or moved to another address, sits outside it. Budget that repair as uncovered unless LG confirms in writing.
Consumables are excluded, including gas, piping and installation materials, and so may a unit that is not reasonably accessible. Four documents carry most claims: the registration confirmation, the dated invoice from an authorised dealer, the warranty card and the service history. Assemble them while the system works.
The LG aircon warranty guide lists every exclusion, from parallel imports to unauthorised repairs. A promotional extension needs written confirmation from the seller before a claim is built on it.
What LG Faults Look Like from the Room
A CH code names the circuit, and the symptoms around it usually confirm it. Fan motor lock, indoor-outdoor communication, low pressure and low refrigerant account for a large share of calls. Write the full code down while the display still shows it.
- CH10: an indoor fan motor has locked or stopped, shown as weak airflow on a unit that keeps running.
- CH05: communication failure between the indoor and outdoor boards, often after a power interruption.
- CH35: low pressure. CH38: a low-refrigerant warning that owners often misread as a drain fault.
- A weak outdoor capacitor makes the compressor hum or click without starting, which sounds like compressor failure.
- Gas lost at a flare or pipe joint returns unless the leak is found and sealed. A pressure test comes before any top-up.
Before Booking a Compressor Repair
LG compressor faults are often a capacitor or board, so test that circuit before comparing compressor quotes. A code that appears after a power cut and stays on points at wiring or a board, not a one-off event. The capacitor is the smaller repair and fails the same way a compressor does, so it is tested first.
Repair or Replace: Framing an LG Decision
Parts supply, panel handling and age set the frame. Recent models sit well on parts, while older ArtCool panels and boards take sourcing. The model suffix decides what fits, so name it before any part is approved.
A significant share of LG compressor calls turn out to be a capacitor or board with identical symptoms. A compressor swap is the most expensive way to find out it was never the compressor.
| Age band | Decision frame | Panel and parts note |
|---|---|---|
| Under 5 years | Sensor, capacitor and installation work | Confirm the registration before assuming cover |
| 5 to 8 years | Capacitor and board replacements are ordinary | ArtCool clips may need attention |
| 8 to 10 years | Board or compressor findings change the frame | Weigh the tested fault against system age |
| Over 10 years | Major faults raise the replacement question | Older panels and boards take sourcing |
The Repair Quote
An LG board replacement or outdoor fan motor repair is quoted from the tested circuit, with the failed part named on the job sheet. For a leak, the pressure test result belongs in the quote.
On an ArtCool, a deep clean that ignores the fascia clips leaves a rattle or uneven airflow. The technician needs to have handled the model.
What to Send for an LG Fault
Send the exact CH code, the model suffix from the invoice or indoor plate and whether the outdoor unit starts. Add when the fault began, whether cooling returns at all and how the unit behaves on start-up.
The code with the start behaviour usually separates a sensor or board fault from a gas problem before a visit is booked. A code alone does not settle whether the cause is a sensor, board, airflow restriction or charge. A photo of the nameplate and one of the display help, because the suffix decides which part is ordered.