- 5.0Google & Carousell
- 15,000+jobs completed
Haier Aircon 10 Error Code & Blinking Light
Confirm the listed meaning of Haier 10, note the unit that shows the code and its model, and match the service manual before diagnosis. Match the model first; same-looking signals can point to different rows.
What does Haier 10 mean?
Haier 10 is listed as outdoor defrost-temperature sensor Te abnormality, outdoor refrigerant-pipe temperature sensor failure, and outdoor defrost-temperature sensor Te failure in the S2 R32 split-system outdoor unit, 2024 1U71 S2 SG / SR outdoor units, 2024 1U90-1U160 S2 outdoor units, and 2024 3U / 4U / 5U S2 multi-split outdoor units fault lists. This meaning comes from the manufacturer's own diagnostic material. Do not collapse this code across model families; use the model, series, or system type to choose the right row. Confirm the exact model, series, or signal row before accepting a parts quote.
What to do now
Use these steps to record evidence and match the installed model to its service manual before diagnosis or a repair quote.
Record 10 and match the service manual
Record 10 and stop there; the manufacturer gives no customer reset procedure. Arrange diagnosis with the matching service manual.
No manufacturer reset steps listed for 10
Capture the complete 10 error code and blinking light and model stickers first. The manufacturer lists the meaning but no customer reset procedure; do not treat a generic power-cycle as manufacturer guidance.
Send these to us
10 error code and blinking light, a clear display photo and blinking-light video if the unit shows one, Haier indoor and outdoor model stickers, the controller, gateway, or unit that reported the code, operating mode and affected area, and any power or setting changes made after the code appeared
Choose the listing that matches your unit
The same code has more than one listed meaning. Match the model family, the system type and the unit that shows the code before approving parts.
| Code | What it means | What to check first |
|---|---|---|
| S2 R32 split-system outdoor unit | Outdoor defrost-temperature sensor Te abnormality | Match this meaning to your installed model and the unit that shows the code, then use the checks below. |
| 2024 1U71 S2 SG / SR outdoor units | Outdoor refrigerant-pipe temperature sensor failure. Shown as: outdoor PCB LED: 10 flashes. | Match this meaning to your installed model and the unit that shows the code, then use the checks below. |
| 2024 1U90-1U160 S2 outdoor units | Outdoor defrost-temperature sensor Te failure | Match this meaning to your installed model and the unit that shows the code, then use the checks below. |
| 2024 3U / 4U / 5U S2 multi-split outdoor units | Defrost-temperature sensor failure | Match this meaning to your installed model and the unit that shows the code, then use the checks below. |
- Code
- S2 R32 split-system outdoor unit
- What it means
- Outdoor defrost-temperature sensor Te abnormality
- What to check first
- Match this meaning to your installed model and the unit that shows the code, then use the checks below.
- Code
- 2024 1U71 S2 SG / SR outdoor units
- What it means
- Outdoor refrigerant-pipe temperature sensor failure. Shown as: outdoor PCB LED: 10 flashes.
- What to check first
- Match this meaning to your installed model and the unit that shows the code, then use the checks below.
- Code
- 2024 1U90-1U160 S2 outdoor units
- What it means
- Outdoor defrost-temperature sensor Te failure
- What to check first
- Match this meaning to your installed model and the unit that shows the code, then use the checks below.
- Code
- 2024 3U / 4U / 5U S2 multi-split outdoor units
- What it means
- Defrost-temperature sensor failure
- What to check first
- Match this meaning to your installed model and the unit that shows the code, then use the checks below.
How this fault may be shown
Match every scope item the source provides—exact model where listed, PCB or panel where listed, and reporting device—before using a displayed value. These manufacturer crosswalks are display evidence, not universal codes or repair instructions.
Multi-Split wired controller YR-E17 / YR-E17ASource-labelled equipment family; exact models are not listed in this table · Haier Split and Multi Split Error Codes, version 01/2024, PDF page 16
| Reported by | Shown as | Listed meaning |
|---|---|---|
| Wired controller YR-E17 or YR-E17A | 1E | Defrost-temperature sensor failure |
- Reported by
- Wired controller YR-E17 or YR-E17A
- Shown as
- 1E
- Listed meaning
- Defrost-temperature sensor failure
Multi-Split wired controller YR-E16 familySource-labelled equipment family; exact models are not listed in this table · Haier Split and Multi Split Error Codes, version 01/2024, PDF page 16
| Reported by | Shown as | Listed meaning |
|---|---|---|
| Wired controller YR-E16, YR-E16A, or YR-E16B | 30 | Defrost-temperature sensor failure |
- Reported by
- Wired controller YR-E16, YR-E16A, or YR-E16B
- Shown as
- 30
- Listed meaning
- Defrost-temperature sensor failure
Multi-Split cassette air-conditioner displaySource-labelled equipment family; exact models are not listed in this table · Haier Split and Multi Split Error Codes, version 01/2024, PDF page 16
| Reported by | Shown as | Listed meaning |
|---|---|---|
| Cassette air-conditioner display | 1E | Defrost-temperature sensor failure |
- Reported by
- Cassette air-conditioner display
- Shown as
- 1E
- Listed meaning
- Defrost-temperature sensor failure
Multi-Split cassette TIMER LED5 / RUNNING LED1Source-labelled equipment family; exact models are not listed in this table · Haier Split and Multi Split Error Codes, version 01/2024, PDF page 16
| Reported by | Shown as | Listed meaning |
|---|---|---|
| Cassette unit TIMER LED5 and RUNNING LED1 | LED5 3 / LED1 0 | Defrost-temperature sensor failure |
- Reported by
- Cassette unit TIMER LED5 and RUNNING LED1
- Shown as
- LED5 3 / LED1 0
- Listed meaning
- Defrost-temperature sensor failure
Multi-Split ceiling-floor, cassette, or duct LED4 / LED3Source-labelled equipment family; exact models are not listed in this table · Haier Split and Multi Split Error Codes, version 01/2024, PDF page 16
| Reported by | Shown as | Listed meaning |
|---|---|---|
| Ceiling-floor, cassette, or duct unit TIMER LED4 and RUNNING LED3 | LED4 3 / LED3 0 | Defrost-temperature sensor failure |
- Reported by
- Ceiling-floor, cassette, or duct unit TIMER LED4 and RUNNING LED3
- Shown as
- LED4 3 / LED3 0
- Listed meaning
- Defrost-temperature sensor failure
Multi-Split wall-unit displaySource-labelled equipment family; exact models are not listed in this table · Haier Split and Multi Split Error Codes, version 01/2024, PDF page 16
| Reported by | Shown as | Listed meaning |
|---|---|---|
| Wall-unit display | F21 | Defrost-temperature sensor failure |
- Reported by
- Wall-unit display
- Shown as
- F21
- Listed meaning
- Defrost-temperature sensor failure
Multi-Split alternate table wired controller YR-E17 / YR-E17ASource-labelled equipment family; exact models are not listed in this table · Haier Split and Multi Split Error Codes, version 01/2024, PDF page 18
| Reported by | Shown as | Listed meaning |
|---|---|---|
| Wired controller YR-E17 or YR-E17A | 1E | Defrost-temperature sensor failure |
- Reported by
- Wired controller YR-E17 or YR-E17A
- Shown as
- 1E
- Listed meaning
- Defrost-temperature sensor failure
Multi-Split alternate table wired controller YR-E16 familySource-labelled equipment family; exact models are not listed in this table · Haier Split and Multi Split Error Codes, version 01/2024, PDF page 18
| Reported by | Shown as | Listed meaning |
|---|---|---|
| Wired controller YR-E16, YR-E16A, or YR-E16B | 30 | Defrost-temperature sensor failure |
- Reported by
- Wired controller YR-E16, YR-E16A, or YR-E16B
- Shown as
- 30
- Listed meaning
- Defrost-temperature sensor failure
Multi-Split duct TIMER LED4 / RUNNING LED3Source-labelled equipment family; exact models are not listed in this table · Haier Split and Multi Split Error Codes, version 01/2024, PDF page 18
| Reported by | Shown as | Listed meaning |
|---|---|---|
| Duct unit TIMER LED4 and RUNNING LED3 | LED4 3 / LED3 0 | Defrost-temperature sensor failure |
- Reported by
- Duct unit TIMER LED4 and RUNNING LED3
- Shown as
- LED4 3 / LED3 0
- Listed meaning
- Defrost-temperature sensor failure
Multi-Split ceiling-floor or cassette TIMER LED6 / RUNNING LED1Source-labelled equipment family; exact models are not listed in this table · Haier Split and Multi Split Error Codes, version 01/2024, PDF page 18
| Reported by | Shown as | Listed meaning |
|---|---|---|
| Ceiling-floor or cassette unit TIMER LED6 and RUNNING LED1 | LED6 3 / LED1 0 | Defrost-temperature sensor failure |
- Reported by
- Ceiling-floor or cassette unit TIMER LED6 and RUNNING LED1
- Shown as
- LED6 3 / LED1 0
- Listed meaning
- Defrost-temperature sensor failure
Multi-Split panel display on PCB 0151800644PCB 0151800644 · Haier Split and Multi Split Error Codes, version 01/2024, PDF page 18
| Reported by | Shown as | Listed meaning |
|---|---|---|
| Duct, ceiling-floor, or cassette panel display | F10 | Defrost-temperature sensor failure |
- Reported by
- Duct, ceiling-floor, or cassette panel display
- Shown as
- F10
- Listed meaning
- Defrost-temperature sensor failure
Split outdoor control board - 1U71 SG / SRModels 1U71S2SG1FA, 1U71S2SR2FA · Haier Split and Multi Split Error Codes, version 01/2024, PDF page 20
| Reported by | Shown as | Listed meaning |
|---|---|---|
| Outdoor control-board diagnostic display | 10 | Defrost-temperature sensor Te failure |
- Reported by
- Outdoor control-board diagnostic display
- Shown as
- 10
- Listed meaning
- Defrost-temperature sensor Te failure
Split outdoor control board - 1U105 SSModels 1U105S2SS1FA, 1U105S2SS2FA · Haier Split and Multi Split Error Codes, version 01/2024, PDF page 20
| Reported by | Shown as | Listed meaning |
|---|---|---|
| Outdoor control-board diagnostic display | 10 | Defrost-temperature sensor Te failure |
- Reported by
- Outdoor control-board diagnostic display
- Shown as
- 10
- Listed meaning
- Defrost-temperature sensor Te failure
Split outdoor control board - 1U125 SN / 1U140 SPModels 1U125S2SN1FA, 1U125S2SN1FB, 1U140S2SP1FA, 1U140S2SP1FB · Haier Split and Multi Split Error Codes, version 01/2024, PDF page 20
| Reported by | Shown as | Listed meaning |
|---|---|---|
| Outdoor control-board diagnostic display | 10 | Defrost-temperature sensor Te failure |
- Reported by
- Outdoor control-board diagnostic display
- Shown as
- 10
- Listed meaning
- Defrost-temperature sensor Te failure
Low-static duct PCB 0151800267 LED4 / LED3PCB 0151800267 · Haier Split and Multi Split Error Codes, version 01/2024, PDF page 21
| Reported by | Shown as | Listed meaning |
|---|---|---|
| Low-static duct TIMER LED4 and RUNNING LED3 | LED4 3 / LED3 0 | Defrost-temperature sensor Te failure |
- Reported by
- Low-static duct TIMER LED4 and RUNNING LED3
- Shown as
- LED4 3 / LED3 0
- Listed meaning
- Defrost-temperature sensor Te failure
Low/medium-static duct PCB 0151800644 LED4 / LED3PCB 0151800644 · Haier Split and Multi Split Error Codes, version 01/2024, PDF page 21
| Reported by | Shown as | Listed meaning |
|---|---|---|
| Low/medium-static duct TIMER LED4 and RUNNING LED3 | LED4 3 / LED3 0 | Defrost-temperature sensor Te failure |
- Reported by
- Low/medium-static duct TIMER LED4 and RUNNING LED3
- Shown as
- LED4 3 / LED3 0
- Listed meaning
- Defrost-temperature sensor Te failure
Low/medium-static duct panel on PCB 0151800644PCB 0151800644 · Panels P1B-890IA/D, P1B-1210IA/D · Haier Split and Multi Split Error Codes, version 01/2024, PDF page 21
| Reported by | Shown as | Listed meaning |
|---|---|---|
| Low/medium-static duct panel display | F10 | Defrost-temperature sensor Te failure |
- Reported by
- Low/medium-static duct panel display
- Shown as
- F10
- Listed meaning
- Defrost-temperature sensor Te failure
AC ceiling/floor TIMER LED6 / RUNNING LED1Models AC35S2SG1FA, AC50S2SG1FA, AC71S2SG1FA, AC90S2SH1FA, AC105S2SH1FA, AC125S2SK1FA, AC140S2SK1FA, AC160S2SK1FA · Haier Split and Multi Split Error Codes, version 01/2024, PDF page 23
| Reported by | Shown as | Listed meaning |
|---|---|---|
| AC ceiling/floor TIMER LED6 and RUNNING LED1 | LED6 3 / LED1 0 | Defrost-temperature sensor Te failure |
- Reported by
- AC ceiling/floor TIMER LED6 and RUNNING LED1
- Shown as
- LED6 3 / LED1 0
- Listed meaning
- Defrost-temperature sensor Te failure
AC ceiling/floor displayModels AC35S2SG1FA, AC50S2SG1FA, AC71S2SG1FA, AC90S2SH1FA, AC105S2SH1FA, AC125S2SK1FA, AC140S2SK1FA, AC160S2SK1FA · Haier Split and Multi Split Error Codes, version 01/2024, PDF page 23
| Reported by | Shown as | Listed meaning |
|---|---|---|
| AC ceiling/floor display | F10 | Defrost-temperature sensor Te failure |
- Reported by
- AC ceiling/floor display
- Shown as
- F10
- Listed meaning
- Defrost-temperature sensor Te failure
AF floor TIMER LED6 / RUNNING LED1Models AF25S2SD1FA, AF35S2SD1FA, AF42S2SD1FA · Haier Split and Multi Split Error Codes, version 01/2024, PDF page 24
| Reported by | Shown as | Listed meaning |
|---|---|---|
| AF floor TIMER LED6 and RUNNING LED1 | LED6 3 / LED1 0 | Defrost-temperature sensor Te failure |
- Reported by
- AF floor TIMER LED6 and RUNNING LED1
- Shown as
- LED6 3 / LED1 0
- Listed meaning
- Defrost-temperature sensor Te failure
AF floor displayModels AF25S2SD1FA, AF35S2SD1FA, AF42S2SD1FA · Haier Split and Multi Split Error Codes, version 01/2024, PDF page 24
| Reported by | Shown as | Listed meaning |
|---|---|---|
| AF floor display | F10 | Defrost-temperature sensor Te failure |
- Reported by
- AF floor display
- Shown as
- F10
- Listed meaning
- Defrost-temperature sensor Te failure
Source-labelled cassette TIMER / RUNNING LEDsSource-labelled equipment family; exact models are not listed in this table · Haier Split and Multi Split Error Codes, version 01/2024, PDF page 25
| Reported by | Shown as | Listed meaning |
|---|---|---|
| Cassette TIMER and RUNNING LEDs | TIMER 3 / RUNNING 0 | Defrost-temperature sensor Te failure |
- Reported by
- Cassette TIMER and RUNNING LEDs
- Shown as
- TIMER 3 / RUNNING 0
- Listed meaning
- Defrost-temperature sensor Te failure
Source-labelled cassette displaySource-labelled equipment family; exact models are not listed in this table · Haier Split and Multi Split Error Codes, version 01/2024, PDF page 25
| Reported by | Shown as | Listed meaning |
|---|---|---|
| Cassette display | 1E | Defrost-temperature sensor Te failure |
- Reported by
- Cassette display
- Shown as
- 1E
- Listed meaning
- Defrost-temperature sensor Te failure
Guidance for your model
Notes that match the code to your exact model. Electrical, refrigerant, wiring, resistance and component checks are for a technician.
| Detail | What it says |
|---|---|
| Singapore / model note | Official Haier Australia S2 split-system manual row. Confirm the exact 1U S2 outdoor model before using the meaning; no universal Haier-model parity is claimed. |
| Singapore / model note | Regional manufacturer handbook, PDF page 11. Confirm the exact listed model and reporting display; this meaning is not claimed for every Haier system. |
| Singapore / model note | Regional manufacturer handbook, PDF page 12. Confirm the exact listed model and reporting display; this meaning is not claimed for every Haier system. |
- Detail
- Singapore / model note
- What it says
- Official Haier Australia S2 split-system manual row. Confirm the exact 1U S2 outdoor model before using the meaning; no universal Haier-model parity is claimed.
- Detail
- Singapore / model note
- What it says
- Regional manufacturer handbook, PDF page 11. Confirm the exact listed model and reporting display; this meaning is not claimed for every Haier system.
- Detail
- Singapore / model note
- What it says
- Regional manufacturer handbook, PDF page 12. Confirm the exact listed model and reporting display; this meaning is not claimed for every Haier system.
What to check before repair
The manufacturer's fault table gives the code's meaning, not a repair procedure. Capture evidence first; model-specific tests belong to the matching service manual.
| You can check | Technician should confirm |
|---|---|
| Photograph the complete 10 error code and blinking light before taking any action. | Confirm 10 exactly and record which controller, gateway, or unit reported it. |
| Capture the Haier indoor and outdoor model stickers and identify which controller or unit reported it. | Match the indoor and outdoor model stickers, installed family, and reporting equipment to the source scope. |
| The manufacturer provides no customer reset procedure. Preserve the evidence and use the matching service manual for any system action. | Follow the matching service-manual procedure and keep measured test evidence before naming a failed part. |
- You can check
- Photograph the complete 10 error code and blinking light before taking any action.
- Technician should confirm
- Confirm 10 exactly and record which controller, gateway, or unit reported it.
- You can check
- Capture the Haier indoor and outdoor model stickers and identify which controller or unit reported it.
- Technician should confirm
- Match the indoor and outdoor model stickers, installed family, and reporting equipment to the source scope.
- You can check
- The manufacturer provides no customer reset procedure. Preserve the evidence and use the matching service manual for any system action.
- Technician should confirm
- Follow the matching service-manual procedure and keep measured test evidence before naming a failed part.
Source-bounded repair decision
Haier 10 confirms the fault label the manufacturer lists, not a failed part or repair procedure. Match the installed model to its service manual and require measured diagnostic evidence before approving parts, settings, or refrigerant work.
Whether the reporting controller or unit and exact installed model are confirmed.
What the matching service-manual procedure and measured tests show.
Whether the proposed repair names the evidence for the failed part or condition.
Haier 10 questions
What does the Haier 10 error mean?
Can I fix a Haier 10 error myself?
Is it safe to keep running the aircon with a 10 error?
What causes a Haier 10 error?
Will a Haier 10 error need a repair or a full replacement?
What should I send a technician about a Haier 10 error?
Where to go next
Confirm the fault
Share the error code, model number and symptoms so we can assess the likely cause.
Not the right code?
Browse the full Haier list or check a few codes in the same fault category.
Read next
Use this quote-check guide only after the matching service manual identifies the diagnostic path.