Skip to main content
snowflakeaircon.sg
WhatsApp
  • 5.0Google & Carousell
  • 15,000+jobs completed

Haier Aircon 116 Error Code

Confirm the listed meaning of Haier 116, note the unit that shows the code and its model, and match the service manual before diagnosis. Match the model first; same-looking codes can point to different rows.

What does Haier 116 mean?

Haier 116 is listed as communication failure between inverter and control PCB and communication error between the module and control board in the MRV-S MVHP outdoor unit and MRV5 AV08-AV26IMVEVA - outdoor failure table fault lists. This meaning comes from the manufacturer's own diagnostic material. Do not collapse this code across model families; use the model, series, or system type to choose the right row. Confirm the exact model, series, or signal row before accepting a parts quote.

What to do now

Use these steps to record evidence and match the installed model to its service manual before diagnosis or a repair quote.

  • Record 116 and match the service manual

    Record 116 and stop there; the manufacturer gives no customer reset procedure. Arrange diagnosis with the matching service manual.

  • No manufacturer reset steps listed for 116

    Capture the complete 116 error code and model stickers first. The manufacturer lists the meaning but no customer reset procedure; do not treat a generic power-cycle as manufacturer guidance.

  • Send these to us

    116 error code, a clear display photo, Haier indoor and outdoor model stickers, the controller, gateway, or unit that reported the code, operating mode and affected area, and any power or setting changes made after the code appeared

Choose the listing that matches your unit

The same code has more than one listed meaning. Match the model family, the system type and the unit that shows the code before approving parts.

  • Code
    MRV-S MVHP outdoor unit
    What it means
    Communication failure between inverter and control PCB
    What to check first
    Match this meaning to your installed model and the unit that shows the code, then use the checks below.
  • Code
    116-1 - compressor module 1
    What it means
    Communication error between the module and control board (compressor module 1)
    What to check first
    Use suffix -1 on the outdoor display to identify compressor module 1.
  • Code
    116-2 - compressor module 2
    What it means
    Communication error between the module and control board (compressor module 2)
    What to check first
    Use suffix -2 on the outdoor display to identify compressor module 2.
  • Code
    116-4 - fan module 1
    What it means
    Communication error between the module and control board (fan module 1)
    What to check first
    Use suffix -4 on the outdoor display to identify fan module 1.
  • Code
    116-5 - fan module 2
    What it means
    Communication error between the module and control board (fan module 2)
    What to check first
    Use suffix -5 on the outdoor display to identify fan module 2.

Guidance for your model

Notes that match the code to your exact model. Electrical, refrigerant, wiring, resistance and component checks are for a technician.

  • Detail
    Singapore / model note
    What it says
    Official Haier America MRV-S MVHP service-manual row. Confirm the exact MVHP outdoor model and reporting display; no universal Singapore-model parity is claimed.
  • Detail
    Singapore / model note
    What it says
    Official regional Haier MRV5 row from outdoor-unit manual 0150525031. Confirm an AV08IMVEVA through AV26IMVEVA system, which unit shows the code, and the complete suffix. The source does not enumerate connected indoor models and is not claimed to cover every Haier system or establish universal Singapore-model parity.

What to check before repair

The manufacturer's fault table gives the code's meaning, not a repair procedure. Capture evidence first; model-specific tests belong to the matching service manual.

  • You can check
    Photograph the complete 116 error code before taking any action.
    Technician should confirm
    Confirm 116 exactly and record which controller, gateway, or unit reported it.
  • You can check
    Capture the Haier indoor and outdoor model stickers and identify which controller or unit reported it.
    Technician should confirm
    Match the indoor and outdoor model stickers, installed family, and reporting equipment to the source scope.
  • You can check
    The manufacturer provides no customer reset procedure. Preserve the evidence and use the matching service manual for any system action.
    Technician should confirm
    Follow the matching service-manual procedure and keep measured test evidence before naming a failed part.

Source-bounded repair decision

Haier 116 confirms the fault label the manufacturer lists, not a failed part or repair procedure. Match the installed model to its service manual and require measured diagnostic evidence before approving parts, settings, or refrigerant work.

  • Whether the reporting controller or unit and exact installed model are confirmed.

  • What the matching service-manual procedure and measured tests show.

  • Whether the proposed repair names the evidence for the failed part or condition.

Haier 116 questions

What does the Haier 116 error mean?
Haier 116 is listed as communication failure between inverter and control PCB and communication error between the module and control board in the MRV-S MVHP outdoor unit and MRV5 AV08-AV26IMVEVA - outdoor failure table fault lists. This meaning comes from the manufacturer's own diagnostic material. Do not collapse this code across model families; use the model, series, or system type to choose the right row. Confirm the exact model, series, or signal row before accepting a parts quote.
Can I fix a Haier 116 error myself?
No. 116 needs a technician's measurement before parts are decided. Photograph the complete 116 error code before taking any action. Capture the Haier indoor and outdoor model stickers and identify which controller or unit reported it.
Is it safe to keep running the aircon with a 116 error?
Record 116 and stop there; the manufacturer gives no customer reset procedure. Arrange diagnosis with the matching service manual.
What causes a Haier 116 error?
Haier 116 has a listed meaning that depends on the exact model and on which unit shows the code. Use the decoder on this page before assuming a specific cause.
Will a Haier 116 error need a repair or a full replacement?
Haier 116 confirms the fault label the manufacturer lists, not a failed part or repair procedure. Match the installed model to its service manual and require measured diagnostic evidence before approving parts, settings, or refrigerant work.
What should I send a technician about a Haier 116 error?
Before booking, send: 116 error code, a clear display photo, Haier indoor and outdoor model stickers, the controller, gateway, or unit that reported the code, operating mode and affected area, and any power or setting changes made after the code appeared.

Where to go next

Confirm the fault

Share the error code, model number and symptoms so we can assess the likely cause.

Read next

Use this quote-check guide only after the matching service manual identifies the diagnostic path.