- 5.0Google & Carousell
- 15,000+jobs completed
Haier Aircon 120 Error Code
Confirm the listed meaning of Haier 120, note the unit that shows the code and its model, and match the service manual before diagnosis. Match the model first; same-looking codes can point to different rows.
What does Haier 120 mean?
Haier 120 is listed as inverter power-supply failure and module power-supply interruption error in the MRV-S MVHP outdoor unit and MRV5 AV08-AV26IMVEVA - outdoor failure table fault lists. This meaning comes from the manufacturer's own diagnostic material. Do not collapse this code across model families; use the model, series, or system type to choose the right row. Confirm the exact model, series, or signal row before accepting a parts quote.
What to do now
Use these steps to record evidence and match the installed model to its service manual before diagnosis or a repair quote.
Record 120 and match the service manual
Record 120 and stop there; the manufacturer gives no customer reset procedure. Arrange diagnosis with the matching service manual.
No manufacturer reset steps listed for 120
Capture the complete 120 error code and model stickers first. The manufacturer lists the meaning but no customer reset procedure; do not treat a generic power-cycle as manufacturer guidance.
Send these to us
120 error code, a clear display photo, Haier indoor and outdoor model stickers, the controller, gateway, or unit that reported the code, operating mode and affected area, and any power or setting changes made after the code appeared
Choose the listing that matches your unit
The same code has more than one listed meaning. Match the model family, the system type and the unit that shows the code before approving parts.
| Code | What it means | What to check first |
|---|---|---|
| MRV-S MVHP outdoor unit | Inverter power-supply failure | Match this meaning to your installed model and the unit that shows the code, then use the checks below. |
| 120-1 - compressor module 1 | Module power-supply interruption error (compressor module 1) | Use suffix -1 on the outdoor display to identify compressor module 1. |
| 120-2 - compressor module 2 | Module power-supply interruption error (compressor module 2) | Use suffix -2 on the outdoor display to identify compressor module 2. |
| 120-4 - fan module 1 | Module power-supply interruption error (fan module 1) | Use suffix -4 on the outdoor display to identify fan module 1. |
| 120-5 - fan module 2 | Module power-supply interruption error (fan module 2) | Use suffix -5 on the outdoor display to identify fan module 2. |
- Code
- MRV-S MVHP outdoor unit
- What it means
- Inverter power-supply failure
- What to check first
- Match this meaning to your installed model and the unit that shows the code, then use the checks below.
- Code
- 120-1 - compressor module 1
- What it means
- Module power-supply interruption error (compressor module 1)
- What to check first
- Use suffix -1 on the outdoor display to identify compressor module 1.
- Code
- 120-2 - compressor module 2
- What it means
- Module power-supply interruption error (compressor module 2)
- What to check first
- Use suffix -2 on the outdoor display to identify compressor module 2.
- Code
- 120-4 - fan module 1
- What it means
- Module power-supply interruption error (fan module 1)
- What to check first
- Use suffix -4 on the outdoor display to identify fan module 1.
- Code
- 120-5 - fan module 2
- What it means
- Module power-supply interruption error (fan module 2)
- What to check first
- Use suffix -5 on the outdoor display to identify fan module 2.
Guidance for your model
Notes that match the code to your exact model. Electrical, refrigerant, wiring, resistance and component checks are for a technician.
| Detail | What it says |
|---|---|
| Singapore / model note | Official Haier America MRV-S MVHP service-manual row. Confirm the exact MVHP outdoor model and reporting display; no universal Singapore-model parity is claimed. |
| Singapore / model note | Official regional Haier MRV5 row from outdoor-unit manual 0150525031. Confirm an AV08IMVEVA through AV26IMVEVA system, which unit shows the code, and the complete suffix. The source does not enumerate connected indoor models and is not claimed to cover every Haier system or establish universal Singapore-model parity. |
- Detail
- Singapore / model note
- What it says
- Official Haier America MRV-S MVHP service-manual row. Confirm the exact MVHP outdoor model and reporting display; no universal Singapore-model parity is claimed.
- Detail
- Singapore / model note
- What it says
- Official regional Haier MRV5 row from outdoor-unit manual 0150525031. Confirm an AV08IMVEVA through AV26IMVEVA system, which unit shows the code, and the complete suffix. The source does not enumerate connected indoor models and is not claimed to cover every Haier system or establish universal Singapore-model parity.
What to check before repair
The manufacturer's fault table gives the code's meaning, not a repair procedure. Capture evidence first; model-specific tests belong to the matching service manual.
| You can check | Technician should confirm |
|---|---|
| Photograph the complete 120 error code before taking any action. | Confirm 120 exactly and record which controller, gateway, or unit reported it. |
| Capture the Haier indoor and outdoor model stickers and identify which controller or unit reported it. | Match the indoor and outdoor model stickers, installed family, and reporting equipment to the source scope. |
| The manufacturer provides no customer reset procedure. Preserve the evidence and use the matching service manual for any system action. | Follow the matching service-manual procedure and keep measured test evidence before naming a failed part. |
- You can check
- Photograph the complete 120 error code before taking any action.
- Technician should confirm
- Confirm 120 exactly and record which controller, gateway, or unit reported it.
- You can check
- Capture the Haier indoor and outdoor model stickers and identify which controller or unit reported it.
- Technician should confirm
- Match the indoor and outdoor model stickers, installed family, and reporting equipment to the source scope.
- You can check
- The manufacturer provides no customer reset procedure. Preserve the evidence and use the matching service manual for any system action.
- Technician should confirm
- Follow the matching service-manual procedure and keep measured test evidence before naming a failed part.
Source-bounded repair decision
Haier 120 confirms the fault label the manufacturer lists, not a failed part or repair procedure. Match the installed model to its service manual and require measured diagnostic evidence before approving parts, settings, or refrigerant work.
Whether the reporting controller or unit and exact installed model are confirmed.
What the matching service-manual procedure and measured tests show.
Whether the proposed repair names the evidence for the failed part or condition.
Haier 120 questions
What does the Haier 120 error mean?
Can I fix a Haier 120 error myself?
Is it safe to keep running the aircon with a 120 error?
What causes a Haier 120 error?
Will a Haier 120 error need a repair or a full replacement?
What should I send a technician about a Haier 120 error?
Where to go next
Confirm the fault
Share the error code, model number and symptoms so we can assess the likely cause.
Not the right code?
Browse the full Haier list or check a few codes in the same fault category.
Read next
Use this quote-check guide only after the matching service manual identifies the diagnostic path.