Skip to main content
snowflakeaircon.sg
WhatsApp
  • 5.0Google & Carousell
  • 15,000+jobs completed

Haier Aircon 29 Error Code

Confirm the listed meaning of Haier 29, note the unit that shows the code and its model, and match the service manual before diagnosis. Match the model first; same-looking codes can point to different rows.

What does Haier 29 mean?

Haier 29 is listed as low-pressure sensor Ps failure, indoor unit B liquid-pipe temperature sensor failure, and outdoor DC fan-motor fault in the MRV-S MVHP outdoor unit, MRV5 AV08-AV26IMVEVA - outdoor failure table, 2024 3U / 4U / 5U S2 multi-split outdoor units, and FlexFit Pro large cassette fault lists. This meaning comes from the manufacturer's own diagnostic material. Do not collapse this code across model families; use the model, series, or system type to choose the right row. Confirm the exact model, series, or signal row before accepting a parts quote.

What to do now

Use these steps to record evidence and match the installed model to its service manual before diagnosis or a repair quote.

  • Record 29 and match the service manual

    Record 29 and stop there; the manufacturer gives no customer reset procedure. Arrange diagnosis with the matching service manual.

  • No manufacturer reset steps listed for 29

    Capture the complete 29 error code and model stickers first. The manufacturer lists the meaning but no customer reset procedure; do not treat a generic power-cycle as manufacturer guidance.

  • Send these to us

    29 error code, a clear display photo, Haier indoor and outdoor model stickers, the controller, gateway, or unit that reported the code, operating mode and affected area, and any power or setting changes made after the code appeared

Choose the listing that matches your unit

The same code has more than one listed meaning. Match the model family, the system type and the unit that shows the code before approving parts.

  • Code
    MRV-S MVHP outdoor unit / MRV5 AV08-AV26IMVEVA - outdoor failure table
    What it means
    Low-pressure sensor Ps failure
    What to check first
    Match this meaning to your installed model and the unit that shows the code, then use the checks below.
  • Code
    2024 3U / 4U / 5U S2 multi-split outdoor units
    What it means
    Indoor unit B liquid-pipe temperature sensor failure
    What to check first
    Match this meaning to your installed model and the unit that shows the code, then use the checks below.
  • Code
    FlexFit Pro large cassette
    What it means
    Outdoor DC fan-motor fault
    What to check first
    Match this meaning to your installed model and the unit that shows the code, then use the checks below.

How this fault may be shown

Match every scope item the source provides—exact model where listed, PCB or panel where listed, and reporting device—before using a displayed value. These manufacturer crosswalks are display evidence, not universal codes or repair instructions.

Multi-Split wired controller YR-E17 / YR-E17ASource-labelled equipment family; exact models are not listed in this table · Haier Split and Multi Split Error Codes, version 01/2024, PDF page 16
  • Reported by
    Wired controller YR-E17 or YR-E17A
    Shown as
    31
Multi-Split wired controller YR-E16 familySource-labelled equipment family; exact models are not listed in this table · Haier Split and Multi Split Error Codes, version 01/2024, PDF page 16
  • Reported by
    Wired controller YR-E16, YR-E16A, or YR-E16B
    Shown as
    49
Multi-Split cassette air-conditioner displaySource-labelled equipment family; exact models are not listed in this table · Haier Split and Multi Split Error Codes, version 01/2024, PDF page 16
  • Reported by
    Cassette air-conditioner display
    Shown as
    31
Multi-Split cassette TIMER LED5 / RUNNING LED1Source-labelled equipment family; exact models are not listed in this table · Haier Split and Multi Split Error Codes, version 01/2024, PDF page 16
  • Reported by
    Cassette unit TIMER LED5 and RUNNING LED1
    Shown as
    LED5 4 / LED1 9
Multi-Split ceiling-floor, cassette, or duct LED4 / LED3Source-labelled equipment family; exact models are not listed in this table · Haier Split and Multi Split Error Codes, version 01/2024, PDF page 16
  • Reported by
    Ceiling-floor, cassette, or duct unit TIMER LED4 and RUNNING LED3
    Shown as
    LED4 4 / LED3 9
Multi-Split wall-unit displaySource-labelled equipment family; exact models are not listed in this table · Haier Split and Multi Split Error Codes, version 01/2024, PDF page 16
  • Reported by
    Wall-unit display
    Shown as
    F16
Multi-Split alternate table wired controller YR-E17 / YR-E17ASource-labelled equipment family; exact models are not listed in this table · Haier Split and Multi Split Error Codes, version 01/2024, PDF page 18
  • Reported by
    Wired controller YR-E17 or YR-E17A
    Shown as
    31
Multi-Split alternate table wired controller YR-E16 familySource-labelled equipment family; exact models are not listed in this table · Haier Split and Multi Split Error Codes, version 01/2024, PDF page 18
  • Reported by
    Wired controller YR-E16, YR-E16A, or YR-E16B
    Shown as
    49
Multi-Split duct TIMER LED4 / RUNNING LED3Source-labelled equipment family; exact models are not listed in this table · Haier Split and Multi Split Error Codes, version 01/2024, PDF page 18
  • Reported by
    Duct unit TIMER LED4 and RUNNING LED3
    Shown as
    LED4 4 / LED3 9
Multi-Split ceiling-floor or cassette TIMER LED6 / RUNNING LED1Source-labelled equipment family; exact models are not listed in this table · Haier Split and Multi Split Error Codes, version 01/2024, PDF page 18
  • Reported by
    Ceiling-floor or cassette unit TIMER LED6 and RUNNING LED1
    Shown as
    LED6 4 / LED1 9
Multi-Split panel display on PCB 0151800644PCB 0151800644 · Haier Split and Multi Split Error Codes, version 01/2024, PDF page 18
  • Reported by
    Duct, ceiling-floor, or cassette panel display
    Shown as
    F29

Guidance for your model

Notes that match the code to your exact model. Electrical, refrigerant, wiring, resistance and component checks are for a technician.

  • Detail
    Singapore / model note
    What it says
    Official Haier America MRV-S MVHP service-manual row. Confirm the exact MVHP outdoor model and reporting display; no universal Singapore-model parity is claimed.
  • Detail
    Singapore / model note
    What it says
    Official regional Haier MRV5 row from outdoor-unit manual 0150525031. Confirm an AV08IMVEVA through AV26IMVEVA system, which unit shows the code, and the complete suffix. The source does not enumerate connected indoor models and is not claimed to cover every Haier system or establish universal Singapore-model parity.
  • Detail
    Singapore / model note
    What it says
    Regional manufacturer handbook, PDF page 15. Confirm the exact listed model and reporting display; this meaning is not claimed for every Haier system.

What to check before repair

The manufacturer's fault table gives the code's meaning, not a repair procedure. Capture evidence first; model-specific tests belong to the matching service manual.

  • You can check
    Photograph the complete 29 error code before taking any action.
    Technician should confirm
    Confirm 29 exactly and record which controller, gateway, or unit reported it.
  • You can check
    Capture the Haier indoor and outdoor model stickers and identify which controller or unit reported it.
    Technician should confirm
    Match the indoor and outdoor model stickers, installed family, and reporting equipment to the source scope.
  • You can check
    The manufacturer provides no customer reset procedure. Preserve the evidence and use the matching service manual for any system action.
    Technician should confirm
    Follow the matching service-manual procedure and keep measured test evidence before naming a failed part.

Source-bounded repair decision

Haier 29 confirms the fault label the manufacturer lists, not a failed part or repair procedure. Match the installed model to its service manual and require measured diagnostic evidence before approving parts, settings, or refrigerant work.

  • Whether the reporting controller or unit and exact installed model are confirmed.

  • What the matching service-manual procedure and measured tests show.

  • Whether the proposed repair names the evidence for the failed part or condition.

Haier 29 questions

What does the Haier 29 error mean?
Haier 29 is listed as low-pressure sensor Ps failure, indoor unit B liquid-pipe temperature sensor failure, and outdoor DC fan-motor fault in the MRV-S MVHP outdoor unit, MRV5 AV08-AV26IMVEVA - outdoor failure table, 2024 3U / 4U / 5U S2 multi-split outdoor units, and FlexFit Pro large cassette fault lists. This meaning comes from the manufacturer's own diagnostic material. Do not collapse this code across model families; use the model, series, or system type to choose the right row. Confirm the exact model, series, or signal row before accepting a parts quote.
Can I fix a Haier 29 error myself?
No. 29 needs a technician's measurement before parts are decided. Photograph the complete 29 error code before taking any action. Capture the Haier indoor and outdoor model stickers and identify which controller or unit reported it.
Is it safe to keep running the aircon with a 29 error?
Record 29 and stop there; the manufacturer gives no customer reset procedure. Arrange diagnosis with the matching service manual.
What causes a Haier 29 error?
Haier 29 has a listed meaning that depends on the exact model and on which unit shows the code. Use the decoder on this page before assuming a specific cause.
Will a Haier 29 error need a repair or a full replacement?
Haier 29 confirms the fault label the manufacturer lists, not a failed part or repair procedure. Match the installed model to its service manual and require measured diagnostic evidence before approving parts, settings, or refrigerant work.
What should I send a technician about a Haier 29 error?
Before booking, send: 29 error code, a clear display photo, Haier indoor and outdoor model stickers, the controller, gateway, or unit that reported the code, operating mode and affected area, and any power or setting changes made after the code appeared.

Where to go next

Confirm the fault

Share the error code, model number and symptoms so we can assess the likely cause.

Read next

Use this quote-check guide only after the matching service manual identifies the diagnostic path.