LG Multi V 5 commercial VRF aircon CH107 error code
Use this LG Multi V 5 commercial VRF CH107 error code guide to decide when to stop resetting, what to capture, and what to check before parts are quoted. Read the final display digit: 1 identifies the master, 2 slave 1, and 3 slave 2.
What does LG CH107 mean?
LG Multi V 5 commercial VRF CH107 is listed as master outdoor unit: Outdoor fan DC-link low-voltage fault, slave 1 outdoor unit: Outdoor fan DC-link low-voltage fault, and slave 2 outdoor unit: Outdoor fan DC-link low-voltage fault in VRF, Cassette, Ducted rows such as LG Multi V 5 commercial VRF. The loaded row is source-backed by official diagnostic material. Use the complete display code and its final digit - 1 for master, 2 for slave 1, or 3 for slave 2 - to choose the reporting outdoor frame before parts are quoted. Confirm the complete display code and whether its final digit identifies the master, slave 1, or slave 2 outdoor frame before accepting a parts quote.
Voltage, current, fuse, module, or power-supply protection has been triggered.
Loose connector, damaged harness, or outdoor electrical component fault.
PCB or inverter-module issue after power and load checks are confirmed.
Choose the matching source row
The same visible code has more than one source-backed meaning. Match the model family, system type, or reporting unit before approving parts.
| Code | What it means | What to check first |
|---|---|---|
| 1071 | master outdoor unit: Outdoor fan DC-link low-voltage fault | Use the complete 1071 display for the master outdoor unit source row. |
| 1072 | slave 1 outdoor unit: Outdoor fan DC-link low-voltage fault | Use the complete 1072 display for the slave 1 outdoor unit source row. |
| 1073 | slave 2 outdoor unit: Outdoor fan DC-link low-voltage fault | Use the complete 1073 display for the slave 2 outdoor unit source row. |
What to do now
Use these steps before another reset or parts quote.
Stop using the unit if CH107 returns
Stop repeated restarts if CH107 returns, trips power, smells burnt, or the outdoor unit runs unusually hot.
Reset CH107 once
Capture the CH107 display, then reset once only if there is no burning smell, repeated trip, or hot outdoor unit.
Send these to us
CH107 error code, a clear display photo, LG Multi V 5 commercial VRF model stickers, affected rooms, reset result, and trip timing and outdoor-unit behaviour
Source-specific guidance
These diagnostic-reference notes help match the code to the exact model. Electrical, refrigerant, wiring, resistance, and component checks are technician work, not DIY steps.
| Source detail | What it says |
|---|---|
| Source repair action | Record 1071 and confirm that the master outdoor unit reported it. Isolate the system through a qualified technician and verify the relevant supply, wiring, inverter, PCB, and compressor path against the installed model manual. |
| Source repair action | Record 1072 and confirm that the slave 1 outdoor unit reported it. Isolate the system through a qualified technician and verify the relevant supply, wiring, inverter, PCB, and compressor path against the installed model manual. |
| Source repair action | Record 1073 and confirm that the slave 2 outdoor unit reported it. Isolate the system through a qualified technician and verify the relevant supply, wiring, inverter, PCB, and compressor path against the installed model manual. |
| Singapore / model note | LG Singapore lists Multi V 5, but the installed unit nameplate and matching service manual control. Do not apply this row to Multi V i or another LG family. Public guidance intentionally omits market-specific electrical thresholds; use the installed Singapore supply and model data. |
What to check before repair
Use this split to separate safe evidence capture from the tests a technician should prove before quoting parts.
| You can check | Technician should confirm |
|---|---|
| Before resetting CH107, take a clear display photo. | Confirm whether CH107 is voltage, current, module, fuse, or protection related. |
| Capture the LG Multi V 5 commercial VRF indoor and outdoor model stickers so the correct family row is used. | Check incoming voltage, connectors, inverter module, and current draw under load. |
| Note whether one room, several rooms, or the whole system is affected, plus whether it returns after one reset. | Confirm downstream loads before replacing electrical boards or modules. |
What changes the next step
These clues decide whether the first check belongs to the master, slave 1, or slave 2 outdoor frame identified by the final display digit.
| What you see | What it points to |
|---|---|
| Only one indoor unit shows CH107. | The affected room, indoor board path, wiring route, or local component should be checked first. |
| Several rooms or the outdoor unit show the same CH107 fault. | The shared outdoor side, power path, communication trunk, or refrigerant circuit needs priority checking. |
| The fault returns immediately after one reset. | Start with the source-row diagnostic branch before approving parts. |
| The final display digit identifies the master, slave 1, or slave 2 outdoor frame. | Match 1 to master, 2 to slave 1, or 3 to slave 2 before checking the shared fault path. |
| The model belongs to VRF, Cassette, Ducted rows such as LG Multi V 5 commercial VRF. | The loaded row is source-backed by official diagnostic material. Use the matching source row before quoting parts. |
Electrical module or wiring decision
LG Multi V 5 commercial VRF CH107 needs voltage, current, module, and load checks before parts are quoted. The repair path depends on whether the fault is supply-side, wiring-side, or board-side.
Supply voltage and load checks separate building-side issues from unit-side faults.
Module or inverter faults need measured current and voltage evidence.
Repeated electrical trips should not be cleared repeatedly without diagnosis.
LG CH107 questions
What does the LG CH107 error mean?
Can I fix a LG CH107 error myself?
Is it safe to keep running the aircon with a CH107 error?
What causes a LG CH107 error?
Will a LG CH107 error need a repair or a full replacement?
What should I send a technician about a LG CH107 error?
Confirm the fault
Share the error code, model number and symptoms so we can assess the likely cause.
Not the right code?
Browse the full LG list or check a few codes in the same fault category.
Ready to get started?
Tell us what’s going on. Symptoms, setup, photos, anything we should know. We’ll assess and come back with the right next step.
Read next