LG Aircon CH45 Error Code & Blinking Light

Capture the LG CH45 fault correctly, then see what should be checked before parts are quoted. Match the model first; same-looking signals can point to different rows.

What does LG CH45 mean?

LG CH45 is listed as middle thermistor of outdoor unit condenser coil is disconnected or shorted, outdoor unit condenser coil middle thermistor disconnected or shorted, and master outdoor unit: Outdoor heat-exchanger pipe temperature sensor error in Wall-Mounted Split, VRF, Cassette rows such as HSV4 / HSV5 single-zone wall-mounted systems, LS091HSV / LS121HSV wall-mounted single-zone. This meaning comes from the manufacturer's own diagnostic material. Do not collapse this code across model families; use the model, series, or system type to choose the right row. Confirm the exact model, series, or signal row before accepting a parts quote.

What to do now

Use these steps before customer action, a sensor check, or PCB quote.

  • Treat it as a fault signal

    If CH45 remains displayed or cooling is still abnormal, preserve the code and arrange diagnosis.

  • No manufacturer reset steps listed for CH45

    Capture the complete CH45 pattern and model stickers first. The manufacturer lists no customer reset procedure; do not treat a generic power-cycle as manufacturer guidance.

  • Send these to us

    CH45 error code and blinking light, a clear display photo and blinking-light video if the unit shows one, LG model stickers, affected rooms, operating state when the code appeared, and when the fault appears

Choose the listing that matches your unit

The same code has more than one listed meaning. Match the model family, the system type and the unit that shows the code before approving parts.

  • Code
    HSV4 / HSV5 single-zone wall-mounted systems
    What it means
    Middle thermistor of outdoor unit condenser coil is disconnected or shorted
    What to check first
    Match this meaning to your installed model and the unit that shows the code, then use the checks below.
  • Code
    LS091HSV / LS121HSV wall-mounted single-zone
    What it means
    Outdoor unit condenser coil middle thermistor disconnected or shorted
    What to check first
    Match this meaning to your installed model and the unit that shows the code, then use the checks below.
  • Code
    LG Multi V 5 commercial VRF — master outdoor unit: Outdoor heat-exchanger pipe temperature sensor error
    What it means
    master outdoor unit: Outdoor heat-exchanger pipe temperature sensor error
    What to check first
    Match this meaning to your installed model and the unit that shows the code, then use the checks below.
  • Code
    LG Multi V 5 commercial VRF — slave 1 outdoor unit: Outdoor heat-exchanger pipe temperature sensor error
    What it means
    slave 1 outdoor unit: Outdoor heat-exchanger pipe temperature sensor error
    What to check first
    Match this meaning to your installed model and the unit that shows the code, then use the checks below.
  • Code
    LG Multi V 5 commercial VRF — slave 2 outdoor unit: Outdoor heat-exchanger pipe temperature sensor error
    What it means
    slave 2 outdoor unit: Outdoor heat-exchanger pipe temperature sensor error
    What to check first
    Match this meaning to your installed model and the unit that shows the code, then use the checks below.

Guidance for your model

Notes that match the code to your exact model. Electrical, refrigerant, wiring, resistance and component checks are for a technician.

  • Detail
    Diagnostic note
    What it says
    Record CH45 and arrange outdoor condenser-coil thermistor and connector diagnosis.
  • Detail
    Diagnostic note
    What it says
    Record the exact code and LED blink pattern before booking diagnosis. For LS091HSV / LS121HSV systems, this pattern points to: Outdoor unit condenser coil middle thermistor disconnected or shorted
  • Detail
    Diagnostic note
    What it says
    Record 451 and confirm that the master outdoor unit reported it. Have an authorised LG VRF technician check the named sensor, connector, harness, and service-manual readings before replacing a board.
  • Detail
    Singapore / model note
    What it says
    Official LG HVAC HSV4 / HSV5 wall-mounted self-diagnosis table. Use this row only for matching single-zone wall-mounted systems.
  • Detail
    Singapore / model note
    What it says
    Use this LS091HSV / LS121HSV LED table only when the installed model or service manual matches this standard wall-mounted single-zone family.
  • Detail
    Singapore / model note
    What it says
    LG Singapore lists Multi V 5, but the installed unit nameplate and matching service manual control. Do not apply this row to Multi V i or another LG family.

What to check before repair

Use this split to separate safe evidence capture from the tests a technician should prove before quoting parts.

  • You can check
    Before taking any system action on CH45, take a clear display photo and blinking-light video if the unit shows one.
    Technician should confirm
    Confirm which sensor CH45 maps to on the exact model table.
  • You can check
    Capture the LG indoor and outdoor model stickers so the correct family row is used.
    Technician should confirm
    Measure the sensor value against the service-manual resistance or voltage range.
  • You can check
    The manufacturer lists no customer reset procedure for this code. Note whether one room, several rooms, or the whole system is affected.
    Technician should confirm
    Check connector condition, harness continuity, and PCB input before replacing boards.

Sensor or PCB decision

LG CH45 is usually repair-first if a sensor or harness reading is confirmed. Board replacement should wait until the sensor circuit is tested.

  • Sensor replacement is usually targeted when resistance or voltage readings are out of range.

  • Harness or connector damage can look like a sensor fault until continuity is checked.

  • PCB replacement is a later step if the sensor and wiring test correctly.

LG CH45 questions

What does the LG CH45 error mean?
LG CH45 is listed as middle thermistor of outdoor unit condenser coil is disconnected or shorted, outdoor unit condenser coil middle thermistor disconnected or shorted, and master outdoor unit: Outdoor heat-exchanger pipe temperature sensor error in Wall-Mounted Split, VRF, Cassette rows such as HSV4 / HSV5 single-zone wall-mounted systems, LS091HSV / LS121HSV wall-mounted single-zone. This meaning comes from the manufacturer's own diagnostic material. Do not collapse this code across model families; use the model, series, or system type to choose the right row. Confirm the exact model, series, or signal row before accepting a parts quote.
Can I fix a LG CH45 error myself?
No. CH45 needs a technician's measurement before parts are decided. Before taking any system action on CH45, take a clear display photo and blinking-light video if the unit shows one. Capture the LG indoor and outdoor model stickers so the correct family row is used.
Is it safe to keep running the aircon with a CH45 error?
If CH45 remains displayed or cooling is still abnormal, preserve the code and arrange diagnosis.
What causes a LG CH45 error?
LG CH45 has a listed meaning that depends on the exact model and on which unit shows the code. Use the decoder on this page before assuming a specific cause.
Will a LG CH45 error need a repair or a full replacement?
LG CH45 is usually repair-first if a sensor or harness reading is confirmed. Board replacement should wait until the sensor circuit is tested.
What should I send a technician about a LG CH45 error?
Before booking, send: CH45 error code and blinking light, a clear display photo and blinking-light video if the unit shows one, LG model stickers, affected rooms, operating state when the code appeared, and when the fault appears.