What does Mitsubishi Electric 4255 mean?
Mitsubishi Electric City Multi 4255 is listed as overcurrent caused by a short-circuited motor in VRF rows such as City Multi VRF outdoor-unit diagnostics. This meaning comes from the manufacturer's own diagnostic material. Confirm the exact model, series, or signal row before accepting a parts quote.
Compressor start, lock, overcurrent, overload, or inverter-drive protection.
Power-module, IPM, voltage, or wiring fault affecting compressor drive.
Compressor mechanical or winding issue after electrical checks are confirmed.
What to do now
Use these steps before customer action or a parts quote.
Stop using the unit if 4255 returns
Stop repeated restarts if 4255 returns; compressor and inverter faults can become more expensive when forced to run.
No manufacturer reset steps listed for 4255
Capture the complete 4255 display and model stickers first. The manufacturer lists no customer reset procedure; do not treat a generic power-cycle as manufacturer guidance.
Send these to us
4255 error code, a clear display photo, Mitsubishi Electric City Multi model stickers, affected rooms, operating state when the code appeared, and trip timing and outdoor-unit behaviour
Guidance for your model
Notes that match the code to your exact model. Electrical, refrigerant, wiring, resistance and component checks are for a technician.
| Detail | What it says |
|---|---|
| Diagnostic note | Check the inverter, compressor, IGBT, fan inverter board, outdoor fan, and outdoor model-selection switch settings. |
| Singapore / model note | Official Mitsubishi Electric Singapore City Multi PDF page 4, primary fault-code table for the outdoor unit. Confirm the installed City Multi equipment and the unit reporting the code before parts replacement. The table also shows preliminary code 4355 in parentheses; it is diagnostic context, not a separate public fault route. |
- Detail
- Diagnostic note
- What it says
- Check the inverter, compressor, IGBT, fan inverter board, outdoor fan, and outdoor model-selection switch settings.
- Detail
- Singapore / model note
- What it says
- Official Mitsubishi Electric Singapore City Multi PDF page 4, primary fault-code table for the outdoor unit. Confirm the installed City Multi equipment and the unit reporting the code before parts replacement. The table also shows preliminary code 4355 in parentheses; it is diagnostic context, not a separate public fault route.
What to check before repair
Use this split to separate safe evidence capture from the tests a technician should prove before quoting parts.
| You can check | Technician should confirm |
|---|---|
| Before taking any system action on 4255, take a clear display photo. | Confirm whether 4255 is compressor start, overload, lock, or drive protection. |
| Capture the Mitsubishi Electric City Multi indoor and outdoor model stickers so the correct family row is used. | Check supply voltage, inverter output, IPM status, compressor current, and winding readings. |
| The manufacturer lists no customer reset procedure for this code. Note whether one room, several rooms, or the whole system is affected. | Review trip history and compressor mechanical signs before quoting replacement. |
- You can check
- Before taking any system action on 4255, take a clear display photo.
- Technician should confirm
- Confirm whether 4255 is compressor start, overload, lock, or drive protection.
- You can check
- Capture the Mitsubishi Electric City Multi indoor and outdoor model stickers so the correct family row is used.
- Technician should confirm
- Check supply voltage, inverter output, IPM status, compressor current, and winding readings.
- You can check
- The manufacturer lists no customer reset procedure for this code. Note whether one room, several rooms, or the whole system is affected.
- Technician should confirm
- Review trip history and compressor mechanical signs before quoting replacement.
What changes the next step
These clues decide whether the first check is room-side, shared outdoor-side, refrigerant-side, listed-meaning, or model-family confirmation.
| What you see | What it points to |
|---|---|
| Only one indoor unit shows 4255. | The affected room, indoor board path, wiring route, or local component should be checked first. |
| Several rooms or the outdoor unit show the same 4255 fault. | Prioritise the shared outdoor side, power path, and source-listed system branch. |
| The outdoor unit hums, starts briefly, or trips soon after startup. | Power, inverter, IPM, compressor current, and winding checks decide the repair path. |
| The model family is different from the row you found online. | Use the model or series filter first; same-looking codes can still belong to different diagnostic tables. |
| The model belongs to VRF rows such as City Multi VRF outdoor-unit diagnostics. | This meaning comes from the manufacturer's own diagnostic material. Match the code to your model's listing before parts are quoted. |
- What you see
- Only one indoor unit shows 4255.
- What it points to
- The affected room, indoor board path, wiring route, or local component should be checked first.
- What you see
- Several rooms or the outdoor unit show the same 4255 fault.
- What it points to
- Prioritise the shared outdoor side, power path, and source-listed system branch.
- What you see
- The outdoor unit hums, starts briefly, or trips soon after startup.
- What it points to
- Power, inverter, IPM, compressor current, and winding checks decide the repair path.
- What you see
- The model family is different from the row you found online.
- What it points to
- Use the model or series filter first; same-looking codes can still belong to different diagnostic tables.
- What you see
- The model belongs to VRF rows such as City Multi VRF outdoor-unit diagnostics.
- What it points to
- This meaning comes from the manufacturer's own diagnostic material. Match the code to your model's listing before parts are quoted.
Compressor drive or replacement decision
Mitsubishi Electric City Multi 4255 can still be a repair if power, inverter, or module checks find the cause. Compressor replacement should be weighed against age, warranty, and the rest of the system condition.
Inverter or IPM faults are not the same as confirmed compressor mechanical failure.
Compressor winding and current readings should be measured before replacement is discussed.
Older systems need a repair-versus-replace check if compressor-side parts are expensive.
Mitsubishi Electric 4255 questions
What does the Mitsubishi Electric 4255 error mean?
Can I fix a Mitsubishi Electric 4255 error myself?
Is it safe to keep running the aircon with a 4255 error?
What causes a Mitsubishi Electric 4255 error?
Will a Mitsubishi Electric 4255 error need a repair or a full replacement?
What should I send a technician about a Mitsubishi Electric 4255 error?
Where to go next
Confirm the fault
Share the error code, model number and symptoms so we can assess the likely cause.
Not the right code?
Browse the full Mitsubishi Electric list or check a few codes in the same fault category.
Read next
Use these if the quote mentions the parts, checks, or repair path this code points to.