Toshiba Aircon 25 Error Code

Toshiba 25 means refrigerant leak detection. Stop using the unit if 25 returns with weak cooling, frost, hissing, or outdoor-unit tripping.

What it means
Refrigerant leak detection.
Is it serious?
Yes. Toshiba 25 is a high-severity refrigerant or pressure fault. Have it diagnosed before relying on the unit.
Can I keep running it?
Stop using the unit if 25 returns with weak cooling, frost, hissing, or outdoor-unit tripping. Do not power-cycle the unit to clear the display. The manufacturer's fault list gives no homeowner fix for 25, so leave it for diagnosis.
Is it worth repairing?
Whether Toshiba 25 is worth repairing depends on the unit's age, the part that has failed, and that repair's cost against a new unit. For this fault type the part is usually in the refrigerant circuit. A leak has to be found and sealed before any gas goes in, and the leak's location sets most of the cost. The code names the fault, not the failed part, so measure before you decide on 25.Toshiba by age, from our Toshiba page:
Toshiba repair-or-replace guidance by system age
System ageUsual call
Under 5 yearsRepair.
5–8 yearsRepair is cost-effective for most faults.
8–10 yearsRepair sensor, drainage and minor electrical faults.
Over 10 yearsA major component failure generally favours replacement.
What it costs to find out
An on-site check in Singapore costs $30 and finds what is causing Toshiba 25 before any repair is quoted. The fee is waived if you go ahead with the quoted work. Rates as of 20 Nov 2026, on our Pricing page.
On this page

What Does Toshiba 25 Mean?

Toshiba 25 is listed as refrigerant leak detection in Wall-Mounted Split, Single-Split, Inverter Split entries such as RAC TU2C-LINK Interface - Residential AC type. This meaning comes from the manufacturer's own diagnostic material. Confirm the exact model and series before accepting a parts quote.

What Causes Toshiba 25?

Toshiba's fault list for RAC TU2C-LINK Interface - Residential AC type gives the meaning of Toshiba 25 but not its causes. These are typical for this fault type, not listed for 25.

  • Low refrigerant, active leak, restriction, or abnormal pressure reading.

  • Dirty condenser, weak outdoor fan, blocked airflow, or high-load operation.

  • Pressure sensor, expansion path, or compressor protection after readings are taken.

What Does a Technician Check for Toshiba 25?

Before quoting parts for Toshiba 25, a technician should match 25 to low-pressure, high-pressure, leak, or refrigerant-cycle protection.

  • Measure operating pressures, coil temperatures, airflow, and outdoor fan condition.

  • Find and seal any leak before refrigerant is added.

  • Detail
    Diagnostic note
    What it says
    Use the remote-controller service mode to confirm the check code, then follow the matching Toshiba service-table checks.
  • Detail
    Singapore / model note
    What it says
    Official Toshiba interface table for Residential AC type. Treat these as interface check-code entries and confirm the exact room-aircon model before parts diagnosis.

Will Toshiba 25 Need a Repair or a New Unit?

Toshiba 25 needs measured pressure, airflow and leak evidence first. No gas goes in until a leak is found and sealed. Replacement only comes up when the leak, compressor or coil repair is uneconomical.

Toshiba 25 Questions

What does the Toshiba 25 error code mean?
Toshiba 25 means refrigerant leak detection, according to Toshiba's fault list for RAC TU2C-LINK Interface - Residential AC type. The code names the fault the unit has detected, not the failed part. A technician confirms which part is at fault by measurement before quoting a repair.
Is it safe to keep running an aircon showing Toshiba 25?
Treat Toshiba 25 as a fault to diagnose, not a display to clear. Stop using the unit if 25 returns with weak cooling, frost, hissing, or outdoor-unit tripping. Do not power-cycle the unit to clear the display. Note the 25 display and when it appeared.
What causes Toshiba 25?
Toshiba's fault list for RAC TU2C-LINK Interface - Residential AC type gives the meaning of Toshiba 25 but not its causes. Typical causes for this fault type are low refrigerant, active leak, restriction, or abnormal pressure reading; dirty condenser, weak outdoor fan, blocked airflow, or high-load operation.
Is Toshiba 25 worth repairing?
Whether Toshiba 25 is worth repairing depends on the unit's age, the part that has failed, and that repair's cost against a new unit. For this fault type the part is usually in the refrigerant circuit. A leak has to be found and sealed before any gas goes in, and the leak's location sets most of the cost.
How much does it cost to find out what is causing Toshiba 25 in Singapore?
An on-site check in Singapore costs $30 and finds what is causing Toshiba 25 before any repair is quoted. The fee is waived if you go ahead with the quoted work. Rates as of 20 Nov 2026, on our Pricing page.