Aircon Repairs Ranked by Cost, from Drain Line to Compressor

Most aircon faults land at the cheap end of the repair list. The expensive ones, a coil or a compressor, are also the ones where replacing the unit becomes a fair question.

On this page

Which aircon repairs cost the most?

A coil or a compressor is the dearest repair on a home aircon, reaching well above the rest. A blocked drain, a leak test or a capacitor sits at the cheap end.

The ranking below uses published Singapore operator rates, with Snowflake Aircon Services' own rates beside them.

Common aircon repairs, cheapest to dearest

Scroll to see more columns

RepairMarket range in SingaporeOur rateWhat moves the price
1. Blocked drain line cleared$50–$150 per unitQuoted per jobWhether the blockage is at the unit or deep in a concealed pipe
2. Gas leak test, single-split system$50–$180 per jobQuoted per jobThe system size and how the test is run
3. Capacitor replaced$70–$150 per jobQuoted per jobCompressor or fan capacitor, and the model
4. Blower wheel replaced, wall-mounted unit$80–$150Whether the wheel is still supplied for the model
5. Gas top-up after the leak is sealed, R32$120–$200How much gas the system needs
6. Fan motor replaced, wall-mounted indoor unit$120–$400 per job$220–$320Motor model, stock and access
7. Circuit board (PCB) replaced, indoor board$150–$400 per job$180–$320Indoor, outdoor or inverter board, and supply
8. Indoor or outdoor coil replaced$200–$1,800 per jobQuoted per jobUnit size and whether the coil must be ordered
9. Compressor or condensing unit replaced$300–$1,500 per jobQuoted per jobSystem size, gas and whether the whole condenser is swapped
Diagnostic visit to name the fault first$30 / visitWaived if you go ahead with the quoted repair

Ranked by the low end of each range, or of Snowflake's own rate where no market range is published. A job's place in a range depends on the brand, the model and access.

Market ranges: published rates from 4 Singapore operators; published rates from 3 Singapore operators; published rates from 6 Singapore operators. Checked between 18 Nov 2026 and 20 Nov 2026.

Our rates are from our rate card.

Where the ranges come from

Each range is the lowest to the highest figure from at least three Singapore operators' published rates for the same job, checked on 18 or 20 November 2026. Rows are ordered by the low end.

Why the same repair has a wide range

Part supply sets most of the spread. A part stocked for the model is a short job; one that must be ordered, or exists only as a used part, costs more and takes longer.

Access adds the rest. A unit on a high ledge, behind a false ceiling or on a concealed pipe run takes longer to reach than an open wall unit.

The cheap faults that look expensive

A diagnostic visit names which one applies before anything is replaced.

  • No cooling with the outdoor unit humming: on a non-inverter unit this can be a capacitor, not the compressor.
  • Water dripping indoors: usually the drain line, not a gas leak.
  • Unit dead with no lights: sometimes the supply or a fuse, before the board.
  • Noise from the indoor unit: often the blower wheel, not the motor.

Where repair stops making sense

The coil and compressor rows are where a replacement quote is worth having. On an aircon over ten years old, a new coil or compressor goes into a system whose other parts are equally worn.

Boards are replaced, not repaired. Snowflake fits a new or matching board and quotes it once the model is confirmed.

Common questions

What is the most expensive aircon repair?
Replacing a coil or a compressor is the most expensive aircon repair on a home system in Singapore. Both reach well above the other common repairs in published operator rates. On a unit more than ten years old, either one is the moment to get a replacement quote before approving the work.
What is the cheapest aircon repair in Singapore?
Clearing a blocked drain line is among the cheapest aircon repairs in Singapore, along with a capacitor replacement and a gas leak test. These sit at the bottom of published operator rates. A dripping indoor unit is the usual sign of a blocked drain, and it is rarely a gas leak.
Is an aircon PCB repaired or replaced?
A failed aircon PCB is replaced, not repaired, at Snowflake Aircon Services. The board is swapped for one matched to the model, and the price is set once the model and board are confirmed. Published Singapore rates put a board replacement in the middle of the common repair costs.
Why do aircon repair quotes vary so much?
Aircon repair quotes vary mainly with part supply and access. A part stocked for the model makes a short, cheaper job, while one that must be ordered costs more. A unit on a high ledge or behind a false ceiling also takes longer to reach than an open wall-mounted unit.