Aircon Thermistor Replacement Cost and Signs of a Bad Sensor

A thermistor is a small temperature sensor, and it is one of the cheaper parts to replace. When it fails, the aircon misreads the room or the coil, which can look like a much bigger fault.

On this page

What does a thermistor replacement cost?

It is one of the cheaper aircon repairs. Published Singapore rates put indoor sensors at the low end and outdoor sensors higher, priced per job.

Snowflake Aircon Services quotes it after testing, so the sensor is confirmed before it is replaced.

Aircon thermistor replacement cost
SensorMarket range in SingaporeOur rate
Thermistor replaced, indoor or outdoor$40–$250 per jobQuoted per job
Diagnostic visit to find the cause$30 / visit

Indoor room and coil sensors sit at the low end; outdoor sensors cost more. The model and whether the sensor is stocked set where a job falls.

Market ranges: published rates from 4 Singapore operators. Checked 20 Nov 2026.

Our rates are from our rate card.

Signs that point to the sensor

Measuring the sensor's resistance against the maker's table confirms the fault. That rules out the board, which can show the same signs.

  • The unit stops cooling early, or keeps running when the room is already cold.
  • A blink pattern or error code that names a sensor.
  • Cooling that cuts in and out with no change in the room.
  • The outdoor unit stops while the indoor fan keeps running.

Sensor or board?

A failed thermistor and a failed board can give the same code. Measuring the sensor first avoids replacing a board for a sensor fault.

If the sensor tests good, the board is the next suspect. Boards are replaced, not repaired.

Common questions

How much does an aircon thermistor replacement cost in Singapore?
An aircon thermistor replacement costs far less than a board or a compressor, and is priced per job in published Singapore operator rates. Indoor room and coil sensors sit at the low end and outdoor sensors cost more. The model and whether the sensor is stocked set the price.
What does an aircon thermistor do?
An aircon thermistor is a small temperature sensor. The unit uses it to read the room, the coil or the outdoor temperature, and adjusts the compressor and fan from those readings. A faulty thermistor makes the aircon misread temperatures, so it cools too little, too much or stops early.
How do I know if my aircon thermistor is faulty?
A faulty aircon thermistor often shows as cooling that stops early or never stops, cooling that cuts in and out, or an error code that names a sensor. Measuring the sensor's resistance against the maker's table confirms the fault and also rules out the board.
Is a thermistor fault the same as a board fault?
No, though they can show the same code. A thermistor is a sensor wired to the board; if it fails, the board receives a wrong reading. Testing the sensor's resistance tells them apart, so a board is not replaced when only the sensor has failed.