Cassette Aircon Servicing Cost and How Often Offices Need It

A ceiling cassette costs more to service than a wall unit, and the gap is in the access, not the cleaning. How often it needs doing depends on the hours it runs and the dust in the room.

On this page

Cassette servicing rates per unit

A general service on a ceiling cassette is priced per unit, and the rate falls with each extra unit up to three. A chemical jet wash is a separate, flat rate per unit.

The table shows Snowflake Aircon Services' own rates from its rate card.

Ceiling cassette aircon servicing cost
Cassette serviceOur rateWhat it covers
General servicing$60 for one unit; $40 each for two; $30 each for three or moreFilter, coil face, blower and drain pan cleaned from below with the panel lowered
Chemical jet wash$280 / unitCoil and blower washed with chemical and flushed, the room below protected

General servicing is priced per unit and falls as more units are serviced in the same visit. The chemical jet wash is one flat rate per unit.

Our rates are from our rate card.

Why a cassette costs more than a wall unit

The work sits overhead. The panel is lowered and supported, and the floor and furniture below are covered before any water is used.

A cassette also carries more to check. It holds a drain pan, a drain pump and a float switch, so a service clears the pan and checks that the water drains away.

How often does a cassette need servicing?

Snowflake Aircon Services advises a general service every three to six months for a ceiling cassette. Running hours and dust decide where in that band a unit sits.

How often does a cassette need servicing? summary table
PremisesWhat fouls the unitWhere in the band
Office, standard hoursPaper dust and recirculated airNearer six months
Retail shop, long hoursDoor traffic and street dustMiddle of the band
Food and beverage outletCooking oil carried in the airNearer three months
Home with a cassetteEvening use onlySix months

General service or chemical jet wash?

A general service handles routine dust. A chemical jet wash is worth paying for when the coil stays dirty after a general clean.

Water dripping from the panel edge is different. It points to the drain pan or the pump, and needs diagnosis before any wash.

  • A musty smell when the unit starts.
  • A coil that looks grey or black behind the grille.
  • Weak airflow even with clean filters.

Servicing several units, or under a contract

Book every cassette on the premises in one visit to reach the lower per-unit tier. Tell us the opening hours, so the work can run before or after trade.

A yearly contract uses the same per-unit rates, paid upfront. Contract units also get priority repair booking and no diagnostic visit fee.

Common questions

Why is cassette aircon servicing more expensive than a wall-mounted unit?
A ceiling cassette is serviced overhead. The panel has to be lowered and supported, the room below covered, and the drain pump and float switch checked as well as the coil and drain pan. A wall-mounted unit has none of that overhead access work, so its servicing rate is lower.
How often should an office ceiling cassette aircon be serviced?
Snowflake Aircon Services advises a general service every three to six months for a ceiling cassette. An office running standard hours usually sits near six months. A shop with long hours and door traffic, or a food outlet with cooking oil in the air, sits nearer three months.
When does a ceiling cassette need a chemical jet wash?
A ceiling cassette needs a chemical jet wash when a general service no longer clears the coil. The signs are a musty smell at start-up, a dark coil behind the grille, or weak airflow that stays weak after the filters are cleaned. Water dripping from the panel needs diagnosis first.
Can cassette aircon servicing be done outside office hours?
Yes. Cassette servicing for offices and shops is usually booked before or after trading hours, because the panel is lowered and the area below is covered during the work. Give the opening hours when booking, so the visit can be planned around them.