On this page
Quick summary
Daikin MKM50ZVMG through MKM100ZVMG are the current iSmileEco+ 5-tick multi-split condensers scaling from System 2 up to System 4 and larger mixed setups. Older MKP50VVMG and MKP75VVMG match them on 5-tick COP but top out at System 3 capacity. Both lines qualify for S$400 Climate Vouchers.
Verified NEA Specs for Daikin iSmileEco vs iSmileEco+ Condensers
Every condenser in both lines runs on R32 gas and carries 5 NEA energy ticks. MKP50VVMG and MKP75VVMG rate slightly higher in cooling kW and weighted COP. Newer MKM ZVMG units use slightly fewer yearly kWh on the NEA test cycle.
The decisive hardware gap appears once a home needs System 4 or heavy living-room capacity. MKP VVMG stops at 6.15 kW (MKP75VVMG), whereas the current MKM ZVMG line extends to MKM85ZVMG (7.35 kW) and MKM100ZVMG (8.62 kW) for four-room and five-room HDB flats or large condos.
Scroll to see more columns
| Daikin outdoor model | NEA COR number | Cooling kW | Full / Part / Weighted COP | Annual kWh (NEA) |
|---|---|---|---|---|
| MKP50VVMG (5-tick) | MELS-DAI-AC200041 | 4.37 kW | 5.18 / 6.65 / 6.06 | 1,553 kWh |
| MKM50ZVMG (5-tick) | ELS-DAI-AC240071 | 4.15 kW | 5.33 / 6.46 / 6.01 | 1,483 kWh |
| MKP75VVMG (5-tick) | MELS-DAI-AC200043 | 6.15 kW | 5.61 / 6.50 / 6.14 | 2,132 kWh |
| MKM75ZVMG (5-tick) | ELS-DAI-AC240069 | 6.07 kW | 5.53 / 6.49 / 6.11 | 2,114 kWh |
| MKM85ZVMG (5-tick) | ELS-DAI-AC240070 | 7.35 kW | 5.07 / 6.56 / 5.96 | 2,716 kWh |
| MKM100ZVMG (5-tick) | ELS-DAI-AC250008 | 8.62 kW | 5.25 / 6.33 / 5.90 | 3,154 kWh |
Published Daikin ZVMG System 2, System 3, and System 4 Installed Rates
Snowflake publishes nett installed prices (rates as of 20 Nov 2026) for the current Daikin iSmileEco+ MKM ZVMG series paired with CTKM25ZVMG indoor fan coils. Every package covers one-trip full installation with up to 50 ft of upgraded piping per room: 22 SWG copper, 1/2-inch Armaflex Shield CX insulation, 16 mm Class 0 insulated drain pipe, NCS upsized trunking, and Sigma or Keystone wire.
Old-system dismantling, disposal, vacuuming, testing, and commissioning are included, backed by 1 year workmanship cover, 1 year agent parts cover, and 5 years agent compressor cover. Stainless-steel brackets (S$200 per unit), a second trip (S$150), and electrical power points are excluded. MKM100ZVMG and mixed-BTU setups are quoted after a S$30 site survey, waived if you proceed.
Scroll to see more columns
| Published Daikin package | Verified outdoor & indoor codes | Installed nett price | Best Singapore flat type |
|---|---|---|---|
| Daikin System 2 (2 x 9,000 BTU) | MKM50ZVMG + CTKM25ZVMG x 2 | S$2,800 nett | 2-room or 3-room HDB bedrooms |
| Daikin System 3 (3 x 9,000 BTU) | MKM75ZVMG + CTKM25ZVMG x 3 | S$4,050 nett | 3-room or 4-room HDB bedrooms |
| Daikin System 4 (4 x 9,000 BTU) | MKM85ZVMG + CTKM25ZVMG x 4 | S$4,950 nett | 4-room or 5-room HDB and condos |
| High-load System 4 / mixed BTU | MKM100ZVMG + mixed CTKM ZVMG | Quoted after S$30 survey (waived) | 5-room HDB, executive flats, large living halls |
Real SP Group Bills, S$400 Climate Vouchers, and EEG Rules
At the Q4 2026 SP Group tariff of 31.16 cents/kWh (with GST, 1 Oct to 31 Dec 2026), the 70 kWh annual difference between MKP50VVMG and MKM50ZVMG equals under S$22 a year. The 18 kWh gap between MKP75VVMG and MKM75ZVMG is under S$6 a year. Sizing the condenser properly for simultaneous room load saves far more power than chasing a 0.03 COP difference.
Singapore HDB flats and Citizen private homes can redeem up to S$400 in NEA Climate Vouchers until 31 December 2027. Both MKP VVMG and MKM ZVMG qualify at participating shops if the exact set stays 5-tick. For offices and clinics, both lines also sit on the GoBusiness EEG list for up to 70% SME hardware support.
How to Pick Between Daikin iSmileEco and iSmileEco+ Before Buying
For most new Singapore installs in 2026, pick the current MKM ZVMG line. Local stock, matched CTKM ZVMG indoor units, and published System 2 to System 4 packages line up cleanly. Only pick MKP50VVMG or MKP75VVMG if an authorised dealer holds local warranty stock at a deep discount.
Confirm these four items before paying any deposit:
- Match your concurrent room load: pick MKM50ZVMG for two bedrooms, MKM75ZVMG for three bedrooms, MKM85ZVMG for four standard rooms, or MKM100ZVMG when cooling a large living hall alongside bedrooms.
- Check that the quotation prints the exact outdoor code (MKM50ZVMG, MKM75ZVMG, MKM85ZVMG, or MKM100ZVMG) instead of writing only Daikin iSmile.
- Confirm whether upsizing a living-room fan coil keeps the exact NEA pairing at 5 ticks before planning S$400 Climate Voucher redemption.
- Book a S$30 Snowflake site survey (waived on install) to verify HDB ledge clearance, 22 SWG pipe runs, and stainless-steel bracket requirements.