Quick summary
Daikin MKM50ZVMG holds NEA 5-tick certificate ELS-DAI-AC240071 with 4.15 kW capacity, 6.01 weighted COP, and 1,483 kWh yearly test use. Snowflake pairs MKM50ZVMG with two CTKM25ZVMG heads for S$2,800 nett, suiting 2-room Flexi and bedroom-focused 3-room flats.
Calculate MKM50ZVMG Efficiency and Nightly SP Group Costs
Certified under ELS-DAI-AC240071 through 15 December 2027, Daikin MKM50ZVMG achieves 5 green ticks at 4.15 kW capacity. Rated efficiency hits 5.33 full load, 6.46 part load, and 6.01 weighted COP.
NEA prints 1,483 kWh annually (S$401 label estimate). Using Singapore's regulated 31.16 cents/kWh rate (Q4 2026 with GST), that yearly figure totals S$462. Cooling a standard bedroom across eight sleeping hours at 25 degrees draws 2.5 to 3.0 kWh (S$23 to S$28 monthly).
Running both heads simultaneously overnight stays near S$45 to S$54 monthly. HDB homeowners also enjoy S$400 NEA voucher savings until December 2027.
Compare MKM50ZVMG Ratings and the S$2,800 Install Package
Check MKM50ZVMG NEA benchmarks, SP Group monthly running estimates, and Snowflake's S$2,800 nett package inclusions:
Scroll to see more columns
| System 2 benchmark | MKM50ZVMG + CTKM25ZVMG x 2 | Cost or NEA figure | HDB flat insight |
|---|---|---|---|
| NEA MELS registration | ELS-DAI-AC240071 (5 ticks) | 4.15 kW | 6.01 weighted COP | 5.33 full-load; 6.46 part-load COP |
| 1 bedroom x 8h nightly (SP 31.16c) | One CTKM25ZVMG at 25 degrees | ~S$23 to S$28 / month | 6.46 part-load COP keeps draw low |
| 2 bedrooms x 8h nightly (SP 31.16c) | Both CTKM25ZVMG heads active | ~S$45 to S$54 / month | 4.15 kW comfortably serves two rooms |
| Snowflake System 2 nett install | MKM50ZVMG + CTKM25ZVMG x 2 | S$2,800 nett (S$400 voucher eligible) | 22 SWG copper + 0.5-inch Armaflex Shield CX |
| Included package warranty | Snowflake & Daikin agent | 1yr work / 1yr parts / 5yr compressor | Up to 50 ft/unit; brackets & power extra |
Plan 2-Room Flexi and 3-Room HDB Cooling Limits Safely
In 2-room Flexi flats, two CTKM25ZVMG heads chill the bedroom and lounge on a tidy 2-port chassis. In 3-room resale flats, MKM50ZVMG serves both bedrooms efficiently when owners rely on a living-room ceiling fan.
Because MKM50ZVMG carries exactly two refrigerant ports, adding a third head later is impossible. Homes expecting hall cooling should install System 3 MKM75ZVMG (S$4,050 nett). Its modest draw fits 30A HDB main switches easily, with thick 22 SWG lines plus Shield CX 1/2-inch Armaflex up to 50 ft per head.
Decide If MKM50ZVMG Fits Your Rooms and Maintenance Rates
Confirm whether two indoor heads cover your five-year routine before trunking goes up, then plan upkeep at flat rates:
- Book a S$30 site survey whenever old brackets or drain paths look doubtful. That S$30 fee waives completely once your S$2,800 System 2 job starts.
- Standard dual-unit general cleaning bills S$30 each (S$60 combined). One-unit calls cost S$50, whereas three-plus units drop to S$25 per coil (14-day cover).
- Chemical washes remove musty drain biofilm from dual bedroom coils at S$70 each (S$140 combined). Solo washes cost S$80, whereas multi-splits of three-plus charge S$60 per unit (60-day warranty).
- Full chemical overhauls restore blocked two-unit blower drums cleanly at S$125 per unit (S$250 total). Solo visits cost S$150, and three-plus heads drop to S$115 each (90-day warranty).
Check Your Diagnostic or Servicing Price
Tap your job, unit count, and home type for our published Singapore rate — then send the pre-filled message on WhatsApp.
Published Singapore estimate
$30 / visit site survey (waived on installation)
Covers piping route check, condenser ledge access, and a firm nett package quote for your 3 indoor units.
1-year installation workmanship warranty + agent parts and 5-year compressor warranty.