Ducted Aircon Replacement in a Condo or Landed Home: Cost

A ducted system's price is set as much by the ceiling around it as by the unit. Whether the ducts, the ceiling opening and the piping can stay decides which of three options makes sense.

On this page

What does replacing a ducted aircon cost?

It depends on which of three options fits: like for like, a switch to wall-mounted units, or a partial change. Each is quoted after a site survey, because the ceiling, ducts and piping set the price.

The table sets out what each option involves, with Snowflake Aircon Services' survey fee from its rate card.

Replacing a ducted aircon: the three options

Scroll to see more columns

OptionMarket range in SingaporeOur rateWhat it involves
Like for like: new ducted unit on the existing ductsOnly two operators publish a ducted supply-and-install price, on different scopes; unit size, ceiling access and duct condition set it.Quoted per jobUnit lowered and replaced through the ceiling opening; ducts and grilles reused if sound
Switch to wall-mounted unitsNo published conversion price was found; the number of rooms and the ceiling repair set it.Ducted unit removed, ceiling made good, wall units and new piping routes added
Partial: replace the outdoor unit or one indoor unitNo published price was found; compatibility with the parts that stay sets it.Only when the remaining parts are compatible and in good order
Site survey before any quote$30 / visitCeiling access, ducts, piping and power checked

Ducted replacement is quoted after a site survey of the ceiling, ducts and piping. The survey fee is waived if you go ahead.

Our rates are from our rate card.

What moves a ducted quote

Four things set most of the price, and a site survey checks each one.

  • The size of the ceiling opening: a small one may have to be enlarged to lower the unit.
  • The ducts: sound ducts and grilles can be reused; crushed or damp ones cannot.
  • The piping: reused only if it passes the same checks as any reused run.
  • The ceiling finish: repairs after the work are part of the price.

Like for like, or switch to wall units?

Stay ducted when the ceiling already has a usable opening and the ducts are sound. The rooms keep their clean ceilings and the new unit goes in the old one's place.

Switch to wall units when the ducts are failing, the opening cannot take a new unit, or you want each room controlled on its own. Expect ceiling repair where the old unit and ducts come out.

Why a survey comes first

A ducted unit's access, ducts and piping are hidden until the ceiling is opened. A quote given without seeing them can only guess, and changes once the work starts.

Ask for the survey findings in writing: the opening size, the duct condition and whether the piping can stay.

Common questions

How much does it cost to replace a ducted aircon in Singapore?
Replacing a ducted aircon in Singapore is usually quoted after a site survey, because the ceiling opening, the ducts and the piping set most of the price. A like-for-like swap on sound ducts costs least, while switching to wall-mounted units adds new piping routes and ceiling repair.
Can I replace a ducted aircon with wall-mounted units?
Yes. A ducted aircon can be replaced with wall-mounted units, one for each room. The ducted unit and its ducts are removed, the ceiling is repaired where they came out, and new piping routes are run to each wall unit. It suits homes whose ducts are failing or where rooms need separate control.
Can the existing ducts be reused with a new ducted aircon?
Often, if the ducts are sound. A new ducted aircon can reuse ducts and grilles that are intact, dry and well sealed, while crushed, damp or mouldy ducts should be replaced. The new unit's airflow also has to suit the existing duct layout, which a site survey checks.
Why does a ducted aircon need a site survey before a quote?
A ducted aircon's access opening, ducts and piping are hidden in the ceiling, so a quote without seeing them can only guess the work. A site survey checks the opening size, the duct condition and the piping, so the quote covers the real job before any ceiling is opened.