Pre-Approved Daikin 5-Tick and VRV Models for EEG Claims

Daikin's pre-approved EEG lineup in Singapore spans 5-tick multi-split and single-split condensers, SkyAir light-commercial packages, mini-VRV decks, and three-phase VRV plants. Matching the exact outdoor unit code to your room load unlocks up to 70% SME hardware co-funding.

On this page

Quick summary

Daikin offers one of the widest commercial lineups on Singapore's pre-approved Energy Efficiency Grant air-conditioner list, spanning 5-tick multi-splits, single-splits, SkyAir cassettes, mini-VRV condensers, and three-phase VRV systems. Always verify exact model suffixes on GoBusiness before filing.

Daikin Model Families Covered Under Singapore EEG Rules

Singapore commercial premises differ sharply in electrical supply and ceiling clearance, so Daikin certifies separate condenser families across single-phase and three-phase brackets. Multi-split combinations require 5 NEA ticks alongside COP ratings from 5.8 upward, while three-phase VRV plants must reach at least 3 ticks.

Contractors and business owners must confirm the exact alphanumeric model suffix on the GoBusiness solution repository on the day of application, because older stock revisions with a different final letter can fail grant verification.

Scroll to see more columns

Daikin model families covered under Singapore EEG rules summary table
Daikin product familyVerified condenser seriesEfficiency requirementTypical Singapore space
5-tick multi-split inverterMKM50/75/85/100VVMG, ZVMG, MKP50/75VVMG5 NEA ticks, COP >= 5.8Offices, clinics, tuition rooms
5-tick single-split inverterRKM25ZVMG, RKM35ZVMG, RKM50ZVMG5 NEA ticksServer closets, compact retail
SkyAir light commercialRZFV71AVMG, RZFV100AVMG, RSUA4/5/6AVMG5-tick / qualifying commercial ratingShophouse cafes, salons, showrooms
Mini-VRV multi-zoneRXMUQ4AVEG, RXMUQ5AVEG, RXMUQ6AVEGQualifying multi-zone efficiencyMulti-storey shophouses, medium offices
Three-phase VRV plantRXQ6AYM to RXQ14BYMG, RXUQ6AYM to RXUQ20BYMG3 NEA ticks or higherLarge restaurants, industrial floors

When Multi-Split Units Beat SkyAir Cassettes in Shops

Compact clinics, dental suites, and partitioned offices with separate treatment rooms normally save more power using MKM or MKP multi-split condensers paired with quiet wall-mounted fan coils. Each room switches independently without cooling empty corridors during off-peak hours.

Open-plan dining halls, retail boutiques, and long shophouse floors benefit from SkyAir RZFV or RSUA outdoor units linked to ceiling cassettes or ducted blowers. Stronger airflow throws chilled air past glass entrances where Singapore tropical heat enters repeatedly.

Three-Phase VRV Checks for Offices and Industrial Units

Upgrading an entire warehouse office or multi-level F&B building to RXQ or RXUQ three-phase VRV equipment stretches hardware value toward the S$30,000 per-company EEG limit quickly. Check landlord electrical capacity and condenser ledge loading before locking tonnage.

Three-phase commercial pipework involves brazed copper headers, refnet joints, and pressure testing that remain self-funded outside the grant. Asking for separated hardware and installation lines keeps your cash budget realistic from day one.

Checklist to Verify Daikin Models Before Portal Submission

Even a single mismatched digit between your quotation, delivery order, and nameplate photo can stall disbursement for months. Run through these checks prior to clicking submit on the grant portal:

  • Verify every Daikin outdoor condenser code live on the GoBusiness air-conditioner repository before uploading your quote.
  • Confirm whether your premises carries single-phase or three-phase power before selecting SkyAir or VRV condensers.
  • Ensure distributor stock availability matches the exact VVMG, ZVMG, AVMG, or BYMG suffix printed on the quotation.
  • Request an on-site Snowflake inspection (S$30 fee, credited back upon installation) to lock verified Daikin specs with zero upfront hardware deposit.

Common Questions

Do older Daikin iSmileEco units with different suffixes still qualify for EEG?
Older Daikin condensers only qualify for Singapore EEG funding if their exact full model code appears on the active GoBusiness pre-approved list when you submit. Discontinued suffixes or lower-tick multi-split pairings below COP 5.8 fail technical validation even if they belong to the same marketing range.
Can a shophouse combine Daikin RKM single-splits and an MKM multi-split in one EEG claim?
Singapore businesses can combine multiple pre-approved Daikin condenser types within a single EEG application as long as every unit serves the same commercial address and appears on the live repository. SME co-funding covers 70% of qualifying hardware until cumulative firm payouts hit the S$30,000 ceiling.
Does the EEG grant pay for Daikin ceiling cassette fascia panels and wireless controllers?
Eligible EEG hardware claims cover the qualifying Daikin outdoor condenser, matched indoor fan coils, and standard supplied fascia or controller accessories invoiced as part of the equipment set. Labour, extra refrigerant piping, drainage pumps, electrical isolators, and 9% GST remain excluded.
How long should a Singapore business allow for Daikin VRV stock delivery?
Standard Daikin MKM, MKP, and RKM split units are typically stocked locally in Singapore for rapid deployment after portal submission, whereas larger RXQ or RXUQ three-phase VRV modules can require distributor lead times. Confirming warehouse stock before applying keeps installation inside your grant validity window.