A leak in the indoor coil is one of the few faults where a whole new indoor unit can cost about the same as the repair. The coil's supply and the unit's age decide which way to go.

On this page

Coil or a new indoor unit?

Replace the coil when it is still supplied for the model and the unit is fairly new. Replace the whole indoor unit when the coil must be ordered from far away, is no longer made, or the unit is old.

On a wall-mounted unit, a new indoor unit can cost about the same as a coil job, and it renews the fan, board and casing as well. Snowflake Aircon Services' rates for both sit beside the market range.

Leaking evaporator coil: coil replacement or a new indoor unit

Scroll to see more columns

OptionMarket range in SingaporeOur rateWhen it makes sense
Replace the coil only, indoor or outdoor coil range$200–$1,800 per jobQuoted per jobThe coil is still supplied and the unit is fairly new
Replace the whole wall-mounted indoor unit$280–$450The coil is out of supply, or the unit is old
Gas charge after either job, R32$120–$200Both options need a vacuum and a recharge

The coil range covers indoor and outdoor coils across unit sizes; a small wall-mounted coil sits low in it. A new indoor unit must be approved for the existing outdoor unit.

Market ranges: published rates from 4 Singapore operators. Checked 18 Nov 2026.

Our rates are from our rate card.

How a coil leak shows

A coil leak is confirmed by testing, not by sight. The test rules out the cheaper joints and pipe sections first.

  • Cooling fades over weeks, then returns after a top-up, then fades again.
  • Oily marks on the coil fins, which a technician may find when the panel is opened.
  • A leak test that finds no fault at the joints or the pipes.

What a new indoor unit needs to match

The replacement indoor unit must be the outdoor unit's brand and appear on that model's approved pairing list. If none is still made, replacing the whole system is the remaining route.

Look at the outdoor unit as well. If it is old, a new indoor unit may soon be followed by a whole new system.

Why a coil leak is worth fixing properly

Topping up gas into a leaking coil buys weeks, not years. Each top-up repeats the cost, and the unit runs short of gas between them.

The fix is a sealed repair, by a new coil or a new indoor unit, followed by a vacuum and a recharge by weight.

Common questions

How much does an aircon evaporator coil replacement cost in Singapore?
Operators in Singapore quote an aircon evaporator coil replacement per job, and the published range is wide because it spans small wall-mounted coils and large ones. Whether the coil is still supplied for the model, and the gas recharge after it, decide where a job falls.
Is it worth replacing a leaking aircon coil?
Replacing a leaking aircon coil is worth it when the coil is still supplied and the unit has years left. On an older wall-mounted unit, or when the coil is out of supply, a new indoor unit approved for the existing outdoor unit is often the better buy, since it renews every indoor part.
Can a leaking evaporator coil be repaired instead of replaced?
A leaking evaporator coil is normally replaced rather than patched, either on its own or with the whole indoor unit. Before that, a leak test rules out the flare joints and pipe sections, because those can be fixed for much less than a coil and are checked first.
How do I know if my aircon coil is leaking?
An aircon coil leak usually shows as cooling that fades over weeks, recovers after a gas top-up and then fades again. A technician may also find oily marks on the coil fins. A leak test confirms it and rules out the joints and pipes, which are cheaper to fix.