Skip to main content

4 Ticks or 5 Ticks: When the Efficient Aircon Pays Back

A 5-tick single split uses about 160 to 280 kWh a year less than the median 4-tick one in the same size band, on NEA's eight-hour figures. At the Q4 2026 tariff that is roughly S$50 to S$90 a year.

On this page

Is a 5-tick aircon worth the extra price?

A 5-tick model is worth it when the price gap is smaller than a few years of the electricity it saves. Divide the price difference by the yearly saving in the table to get the payback in years.

The table compares the median 4-tick and 5-tick single split in each size band on NEA's register of 21 November 2026, counted by register entry. NEA's annual energy figure assumes 8 hours of use and 16 hours of standby a day. The saving uses SP Group's Q4 2026 tariff of 31.16 cents per kWh with GST.

Scroll to see more columns

Is a 5-tick aircon worth the extra price? summary table
Size bandEntries compared (4 / 5 ticks)Yearly kWh saved by 5 ticksYearly saving, 8 hours a dayYearly saving, 12 hours a day (upper estimate)
3 to 3.9 kW (about 12,000 BTU)12 / 17161About S$50Up to about S$75
4 to 5.5 kW (about 18,000 BTU)25 / 7280About S$87Up to about S$131
5.6 to 7.5 kW (about 24,000 BTU)28 / 5231About S$72Up to about S$108

Where the choice does not exist

There is no 3-tick split aircon to choose. NEA's minimum energy performance standard requires a single-split inverter to exceed a weighted COP of 4.86, which is the 4-tick threshold. Every split on the register carries 4 or 5 ticks.

Multi-splits have one rating. NEA sets their minimum above a weighted COP of 5.50, the 5-tick level, so every System 2, 3 and 4 on the register is 5 ticks. At about 9,000 BTU the choice has also mostly gone: 22 of the 23 single-split register entries from 2 to 2.9 kW are 5 ticks.

Why a 4-tick model can match a 5-tick one

Ticks depend on standby power as well as efficiency. A 5-tick single-split inverter needs a weighted COP of at least 5.50 and standby power of 4 W or less, while 4 ticks allows up to 18 W. Twelve 4-tick single splits on the register reach a weighted COP of 5.50 or more; the register does not publish standby, so the limit is the likely reason.

Compare the annual energy figures of the two quoted models, not only the ticks. The aircon running cost calculator works out a bill from a model's figures and your hours.

What counts more than the ticks

Size comes before efficiency. Snowflake Aircon Services sizes each room before comparing ratings, because an oversized unit cycles on and off and loses part of the gain a higher rating promises.

Snowflake Aircon Services checks both quoted models on the register and the sizes against the rooms before comparing prices.

Common questions

Can I still buy a 3-tick aircon in Singapore?
Split aircons on NEA's register carry only 4 or 5 ticks, so a 3-tick split is not a choice. NEA's minimum standard requires a single-split inverter to exceed a weighted COP of 4.86, the 4-tick threshold. Lower ratings appear only on casement, window and portable units.
How much does a 5-tick aircon save over a 4-tick one?
A 5-tick single split saves about S$50 to S$90 a year over the median 4-tick one of the same size, at NEA's 8 hours a day and SP Group's Q4 2026 tariff of 31.16 cents per kWh. At 12 hours a day the saving is at most about S$75 to S$130.
Is every System 4 aircon 5 ticks?
Every System 2, 3 and 4 multi-split on NEA's register is 5 ticks. NEA sets the multi-split minimum above a weighted COP of 5.50, which is also the 5-tick threshold, so a multi-split cannot be sold with fewer ticks. Compare multi-splits on their annual energy figure instead.
How do I work out the payback on a 5-tick aircon?
The payback on a 5-tick aircon is the price difference between the two quoted models divided by the yearly electricity saving. Take each model's annual kWh from NEA's register, multiply the gap by the tariff and adjust for your hours of use. A gap that takes over a decade to recover rarely pays back.

Sources