Is a 5-tick aircon worth the extra price?
A 5-tick model is worth it when the price gap is smaller than a few years of the electricity it saves. Divide the price difference by the yearly saving in the table to get the payback in years.
The table compares the median 4-tick and 5-tick single split in each size band on NEA's register of 21 November 2026, counted by register entry. NEA's annual energy figure assumes 8 hours of use and 16 hours of standby a day. The saving uses SP Group's Q4 2026 tariff of 31.16 cents per kWh with GST.
Scroll to see more columns
| Size band | Entries compared (4 / 5 ticks) | Yearly kWh saved by 5 ticks | Yearly saving, 8 hours a day | Yearly saving, 12 hours a day (upper estimate) |
|---|---|---|---|---|
| 3 to 3.9 kW (about 12,000 BTU) | 12 / 17 | 161 | About S$50 | Up to about S$75 |
| 4 to 5.5 kW (about 18,000 BTU) | 25 / 7 | 280 | About S$87 | Up to about S$131 |
| 5.6 to 7.5 kW (about 24,000 BTU) | 28 / 5 | 231 | About S$72 | Up to about S$108 |
Where the choice does not exist
There is no 3-tick split aircon to choose. NEA's minimum energy performance standard requires a single-split inverter to exceed a weighted COP of 4.86, which is the 4-tick threshold. Every split on the register carries 4 or 5 ticks.
Multi-splits have one rating. NEA sets their minimum above a weighted COP of 5.50, the 5-tick level, so every System 2, 3 and 4 on the register is 5 ticks. At about 9,000 BTU the choice has also mostly gone: 22 of the 23 single-split register entries from 2 to 2.9 kW are 5 ticks.
Why a 4-tick model can match a 5-tick one
Ticks depend on standby power as well as efficiency. A 5-tick single-split inverter needs a weighted COP of at least 5.50 and standby power of 4 W or less, while 4 ticks allows up to 18 W. Twelve 4-tick single splits on the register reach a weighted COP of 5.50 or more; the register does not publish standby, so the limit is the likely reason.
Compare the annual energy figures of the two quoted models, not only the ticks. The aircon running cost calculator works out a bill from a model's figures and your hours.
What counts more than the ticks
Size comes before efficiency. Snowflake Aircon Services sizes each room before comparing ratings, because an oversized unit cycles on and off and loses part of the gain a higher rating promises.