Fujitsu vs Daikin Aircon: Efficiency and Warranty Compared

Fujitsu holds several of the most efficient single splits on NEA's register, and Daikin has the broader multi-split range. The warranty terms sit closer than the efficiency numbers.

On this page

Fujitsu or Daikin?

For a single room, Fujitsu's 9,000 BTU AOAG09CMTA leads its size class on weighted COP on NEA's register, ahead of Daikin's RKM25ZVMG. For a whole flat on one outdoor unit, Daikin has more multi-split sizes registered.

On warranty, both cover parts for year one. The compressor part is covered for five years, and labour is charged after that.

Fujitsu or Daikin? summary table
FujitsuDaikin
Single split, 9,000 BTU classAOAG09CMTA: 2.87 kW, 5 ticks, weighted COP 6.28RKM25ZVMG: 2.45 kW, 5 ticks, weighted COP 5.56
Multi-split outdoor units on the register2, up to 7.68 kW10, up to 8.62 kW
General warranty1 year, parts and labour, through the Singapore agent15 months from delivery or 12 from installation, whichever is earlier
Compressor warranty5 years, sealed compressor parts only; labour, materials and refrigerant excluded5 years, compressor only; labour charged after the general warranty
RegistrationE-warranty form with the Singapore agentWithin 14 days of installation for full cover

Reading the efficiency figures

Weighted COP is how NEA rates the cooling delivered for each unit of electricity used. Fujitsu's AOAG09CMTA is also larger than Daikin's RKM25ZVMG, so compare units of a similar size when choosing.

Snowflake Aircon Services puts Mitsubishi Electric Starmex first for new installations and quotes Daikin too.

After the first year

Fujitsu's Singapore agent states that after the first year all labour, transport and parts costs fall on the owner, apart from the compressor part. Daikin's compressor cover also leaves labour to the owner after its general warranty.

Common questions

Is Fujitsu better than Daikin aircon?
For a single room, Fujitsu's AOAG09CMTA has a higher weighted COP on NEA's register than Daikin's RKM25ZVMG. For a multi-split serving a whole flat, Daikin has more sizes registered. On warranty, the compressor part is covered for five years on both, and labour is charged from year two.
What does the Fujitsu aircon warranty cover in Singapore?
Fujitsu's Singapore agent, Winfinity, gives a one-year warranty on parts and labour, excluding servicing, and five years on the sealed compressor parts only, excluding labour, materials and refrigerant. After the first year, the agent states that labour, transport and parts costs are borne by the owner.
Which is more energy efficient, Fujitsu or Daikin?
At the 9,000 BTU size, Fujitsu's AOAG09CMTA has a weighted COP of 6.28 on NEA's register, against 5.56 for Daikin's RKM25ZVMG, though the Fujitsu is the larger unit. Compare models of similar capacity before deciding, because efficiency varies across each brand's range and size.
Do Fujitsu and Daikin need warranty registration?
Yes. For full warranty coverage, Daikin Singapore wants the unit registered no later than 14 days after installation, and Fujitsu's Singapore agent, Winfinity, runs an e-warranty registration form. Register promptly after installation, and file the confirmation alongside the invoice and installation record for any later claim.