Gree E1, E2, E4 and E5 Pressure, Freeze and Current Guide

Gree E1, E2, E4 and E5 protection codes guard the sealed refrigeration loop and inverter drive against high condenser pressure, indoor coil icing, hot compressor discharge, and excessive operating current. Pinpointing whether airflow, refrigerant charge, or electrical load caused the trip avoids repeat breakdowns.

On this page

Verified meanings of Gree E1, E2, E4 and E5 codes

Gree multi-split condensers installed across HDB and private apartments, including 5-tick models such as GWCD-MS21/O and GWCD-MS28/O, rely on four core protection cutoffs to prevent compressor burnout. Although E1, E2, E4 and E5 all stop bedroom cooling, each signals a distinct physical stress inside the aircon.

Turn the bedroom wall unit off using the remote controller as soon as any code flashes. Keep wall isolators and distribution breakers untouched rather than forcing resets, especially after an E5 over-current shutdown.

Verified meanings of Gree E1, E2, E4 and E5 codes summary table
Gree CodeVerified Protection FaultKey Field Checks
E1High-pressure protectionInspect fouled outdoor condenser coil, blocked ledge exhaust, slow outdoor fan, or excess gas.
E2Evaporator anti-freezing protectionCheck clogged indoor blower wheel, dirty filters, low refrigerant charge, or indoor coil sensor.
E4High discharge temperature protection of compressorVerify refrigerant leak points, clogged capillary/expansion valve, and discharge probe reading.
E5Over-current protectionMeasure flat supply voltage, compressor amp draw, outdoor heat rejection, and outdoor PCB.

Why airflow blockage drives E1 high pressure and E2 icing

Poor heat transfer sits behind a large share of Singapore E1 and E2 calls. When thick lint coats the outdoor condenser fins or balcony screens trap hot exhaust air around the compressor, condensing pressure spikes until E1 cuts operation.

Inside the bedroom, E2 anti-freezing protection trips when restricted indoor airflow over a jelly-clogged blower barrel or neglected filters lets evaporator coil temperature plunge toward zero degrees. Low refrigerant pressure produces identical icing, so technicians verify both indoor airflow and suction pressures.

Tracing E4 compressor heat and E5 over-current trips

Code E4 signals excessive compressor discharge temperature, commonly traced to slow R32 refrigerant leakage at flare joints, partial valve restriction, or a drifted discharge thermistor. Technicians pressure-test and fix leaks before recharging refrigerant by weight.

Code E5 monitors excessive electrical current draw caused by high head pressure, unstable incoming voltage, a stalling compressor, or a failing current-sensing outdoor board. Where probing confirms a damaged outdoor inverter PCB, full board replacement is carried out rather than component-level soldering.

Common questions

Can washing dirty indoor filters and coils resolve a Gree E2 error?
Deep cleaning clogged indoor filters, evaporator fins, and blower wheels resolves Gree E2 anti-freezing stops whenever restricted indoor airflow caused coil icing. If ice still forms after restoring strong airflow, technicians check for low refrigerant leaks or a drifted indoor coil temperature sensor.
How do Gree E1 high pressure and E4 high discharge temperature differ?
Gree E1 trips when outdoor condensing pressure climbs excessively from dirty condenser coils, trapped ledge exhaust air, weak outdoor fans, or overcharged gas. Gree E4 flags dangerously hot compressor discharge gas, more frequently triggered by low refrigerant leaks, restricted expansion flow, or faulty discharge sensors.
What checks are needed after a Gree E5 over-current protection shutdown?
Technicians check incoming mains voltage, outdoor condenser airflow, and live compressor amperage with a clamp meter before replacing parts for Gree E5. If compressor windings test healthy and pressure stays normal yet E5 recurs, complete outdoor PCB replacement resolves faulty current-sensing hardware.