LG CH01, CH02 and CH10 Indoor Sensor and Fan Fault Guide

LG CH01 signals an indoor unit room temperature sensor error, CH02 marks an indoor unit inlet pipe sensor error, and CH10 reports an indoor BLDC fan lock or indoor fan motor operation failure. All three faults originate inside the wall-mounted indoor assembly.

On this page

Verified LG CH01, CH02 and CH10 meanings

LG residential splits display CH-prefix faults directly on the front panel or via blink counts on minimalist fascias. CH01 means the indoor unit room temperature sensor reads open-circuit or shorted, preventing accurate thermostat control. CH02 points to the indoor unit inlet pipe sensor, which monitors evaporator refrigerant entry temperature to prevent coil icing.

CH10 marks an indoor BLDC fan lock or indoor fan motor operation failure, meaning the cross-flow blower stopped rotating or stopped reporting speed feedback to the indoor board.

Verified LG CH01, CH02 and CH10 meanings summary table
LG codeFault categoryVerified LG meaning and inspection point
CH01Sensor FaultIndoor unit room temperature sensor error; check intake air thermistor resistance and white harness plug.
CH02Sensor FaultIndoor unit inlet pipe sensor error; test evaporator-in copper sleeve thermistor and moisture seal.
CH10Fan Motor FaultIndoor BLDC fan lock or indoor fan motor operation failure; inspect blower obstruction, motor windings, and indoor PCB.

Why wet servicing and humidity trigger sensor faults

High Singapore humidity and careless water-bag chemical washing can push condensation or alkaline cleaner into thermistor plugs mounted beside the evaporator header. Measuring kilo-ohm values at room temperature immediately distinguishes a failed CH01 or CH02 thermistor harness from an indoor PCB sensing-port defect.

For CH10, checking whether the blower wheel glides smoothly by hand rules out warped blades or trapped dirt before testing the BLDC motor and board rails. Any defective LG indoor PCB is replaced as a new assembly rather than repaired with soldering.

Preparing for an LG technician visit

Switch the affected room unit off with the remote and avoid opening the plastic electrical box or cycling mains isolators to clear the display. Leaving the fault state intact lets a technician capture accurate live voltage and resistance figures on arrival.

Photograph the LG indoor model badge and note whether your outdoor unit belongs to a multi-split such as Z4UQ34GFA1. Drop those details into a WhatsApp chat with Snowflake Aircon Services to schedule accurate troubleshooting.

Common questions

Are LG CH01 and CH02 thermistors sold as one dual harness?
Many LG wall-mounted indoor units combine the CH01 room air sensor and CH02 inlet pipe sensor onto a single dual-lead connector plug inside the evaporator housing. Checking exact indoor model compatibility confirms whether both faulty thermistors swap cleanly as one factory-sealed LG sensor assembly.
Can a stalled LG CH10 fan motor damage the indoor board?
An internally shorted BLDC motor causing LG CH10 can overload the indoor board driver circuit whenever mains power is repeatedly forced back on. Measuring motor winding resistance and checking shaft rotation before energizing a replacement indoor PCB prevents immediate repeat board damage.
Why did LG CH02 appear right after an aircon wash?
Pressurized water spray or chemical cleaner forced into the evaporator pipe thermistor sleeve or indoor board socket during aircon servicing can short the CH02 circuit or corrode connector pins. Drying the socket and measuring thermistor resistance confirms whether the probe requires replacement.