MEPS explained: the floor under every aircon sold here

A tick count looks like a scale running from cheap to good. It is not. The bottom of that scale is set by law, it has moved four times since 2011, and every move deleted the models beneath it.

By Team Snowflake | Updated 7 Aug 2026

MEPS is a supply rule, not a rating

Minimum Energy Performance Standards set the lowest efficiency a model may have and still be put on sale in Singapore. Nothing about it is a score. It is a condition of being supplied at all. NEA states the position without qualification: supplying or importing a regulated good that does not meet the prescribed requirements is prohibited, and the power sits in Part III Division 1 of the Energy Conservation Act.

The scope is drawn narrowly and by machine type. Regulated household aircon covers casement and window units up to 8.8 kW, split-type units up to 17.6 kW in both inverter and non-inverter form, and single-phase portable units with one exhaust duct up to 12 kW. Three-phase VRF equipment carries its own standard on a different measure. A machine outside those definitions is outside the rule.

The prohibition binds whoever supplies the machine, not whoever owns it. A raised floor does not make an installed system unlawful and creates no obligation to replace anything. Servicing, repair and continued use are untouched. What changes is what a retailer may put on the shelf tomorrow.

Registration and the printed label are the other half of the same scheme, and they are a separate obligation under the Mandatory Energy Labelling Scheme. Refrigerant limits are a third regime again, with their own dates and their own measure. This page is about the standard a model had to clear before any of that paperwork could exist.

What the floor is written in

The floor is expressed in the same efficiency ratio the tick bands use, and that shared measure is what lets one act on the other. For a non-inverter model it is stated as COP at full load. For a model that modulates, it is stated as weighted COP. What those ratios measure, and why the weighting exists, is a separate subject and stays there.

Efficiency is not the only condition. A standby power ceiling sits beside the ratio, measured in watts, and a model has to clear both. On a multi-split that ceiling scales with the count of indoor and outdoor units rather than sitting at a fixed number, so a larger system is not given a larger allowance per box.

Standby power entered the scheme in 2014 as a five-tick condition only, and was later pushed down the scale. It is easy to overlook on a specification sheet because it is a small figure next to a cooling capacity. It is still part of what a model has to satisfy before it can be supplied.

Where the floor sits on the tick scale today

On a single split the floor is the 4-tick threshold. On a multi-split it is the 5-tick threshold. Those are not merely close to the tick bands. They are the same numbers.

Since 1 April 2025 a single split has needed a COP of at least 4.86, weighted for a modulating model, with standby power no higher than 18 watts. A multi-split has needed 5.50 on the same measure, with standby scaled to the number of indoor and outdoor units. Casement and window machines sit at 3.78. A single-phase portable with one exhaust duct sits at 3.0.

Set those four figures against NEA's published tick bands and a pattern falls out. 4.86 is where the 4-tick band for a single split begins. 5.50 is where 5-tick begins for a multi-split. 3.78 is where 2-tick begins for a casement machine, and 3.0 is where 1-tick begins for a portable. In every format the minimum lands exactly on the lower edge of a band.

The bands underneath are not thinly stocked. They are marked N/A on NEA's own table. A single split has no 1-tick, 2-tick or 3-tick band left in existence. A multi-split has nothing below 5-tick at all. The scale did not empty because manufacturers lost interest in the bottom of it. It emptied because the law came up to meet it.

Where the floor sits on the tick scale today summary table
System typeSingle split, inverter or notMinimum in force nowCOP 4.86, standby 18 WTick bands that still exist4-tick and 5-tick
System typeMulti-split, inverter or not (system 2, 3, 4)Minimum in force nowCOP 5.50, standby 7 W per indoor and outdoor unitTick bands that still exist5-tick alone
System typeCasement and window, up to 8.8 kWMinimum in force nowCOP 3.78Tick bands that still exist2-tick through 5-tick
System typeSingle-phase portable, one exhaust ductMinimum in force nowCOP 3.0Tick bands that still exist1-tick and 2-tick

What happens to the market each time the floor rises

Aircon came under the standard on 1 September 2011, pitched at what was then the 2-tick level. It has been lifted four times since, and NEA publishes the whole sequence as a dated implementation record rather than leaving it to be inferred.

Read that record as a series of deletions rather than a series of targets. A raise does not make the models below it poor value or discourage anybody from buying them. It removes them. The manufacturer withdraws the range, the retailer clears the last of the stock, and a band that had products in it last year has none in it this year.

One provision decides when any of this reaches a shop floor. Each raise comes with a transitional window for goods already in the country. For the April 2025 change NEA gave suppliers one year, ending 31 March 2026, to clear stock that did not meet the new standard. From 1 April 2026 every regulated model has to be registered and compliant before it may be supplied.

That window shut recently enough to catch out anything a shopper reads secondhand. A review, a forum thread or a retailer page written before April 2026 can describe machines that are no longer supplied here at all. Guidance along the lines of saving money on a 3-tick split was ordinary advice once. It now points at a category that cannot lawfully be sold.

What happens to the market each time the floor rises summary table
When the floor moved1 Sep 2011Where it moved toThe 2-tick level of the scale then in useWhat left the marketThe first household models ruled out of supply
When the floor moved1 Sep 2013Where it moved toThe 3-tick level of that same older scaleWhat left the marketOne further band from the bottom of it
When the floor moved1 Sep 2016Where it moved toThe present 2-tick level, single and multi splitsWhat left the marketEverything below it on the revised scale
When the floor moved1 Jan 2022Where it moved to2-tick for casement and window, splits up 7 per centWhat left the marketThe weaker models inside the surviving band
When the floor moved1 Apr 2025Where it moved to4-tick for single splits, 5-tick for multi splitsWhat left the marketAll split-type bands below the new minimums

Why the scale loses bands from the bottom

The label and the floor are written in one measure, so lifting either one squeezes the other. A tick band is the range between two values of that measure. Push the minimum up to a band's lower edge and every band beneath has nothing left to describe.

This is why the tick scale is not a fixed thing to calibrate a judgement against. Its bottom is wherever the standard currently sits. Its top has not moved in either direction, and 5-tick still begins where it always began. What changed is how much of the range still holds products.

Anybody who learned the scale before 2025 learned a five-band scale, and that is now wrong for the two formats most households buy. On a single split the range is two bands wide. For a multi-split, one band is all that remains.

What a tick count can and cannot separate now

On a multi-split the count has stopped carrying information. Every system 2, 3 and 4 on sale clears 5.50, because nothing below that may be supplied. A salesperson presenting five ticks as a property of one particular model is describing the entry requirement for the entire category.

Push back when a recommendation in that category rests on the tick count and nothing else. The band has a floor and no ceiling, so the models sitting in it are not level with one another. Separating them means asking for the efficiency figure each model measures, which is a different exercise from reading the label and is set out where the metric is explained.

On a single split the count still separates something, because two bands survive. What it separates is a machine at the legal minimum from a machine clearly above it. That is a narrower claim than treating four ticks as the budget tier. There is no tier below it to be the budget one.

Ticks also stop comparing once formats differ, because each format is anchored to its own floor. The portable scale has two bands, and the top one begins at 3.25. A single split cannot be supplied at all under 4.86. Two ticks of apparent difference hide a much larger real one, and no arithmetic performed on tick counts will recover it. Across formats, compare the ratio and ignore the label.

Buying against a floor that keeps moving

The question worth asking is not how many ticks a budget reaches. It is how far above the current minimum a machine sits, and how long that position will still look defensible.

A unit bought at the minimum met the lowest standard permitted on the day it was sold. That is not a defect and it is often the right trade. It is worth naming because the interval between raises has run from two years to six, and a split system comfortably outlives that. Buying at the bottom of the surviving range means owning something that reads as the bottom for most of its service life.

None of this creates a duty on an owner. The standard binds supply. An installed machine stays lawful, keeps whatever cover it came with, and can be serviced and repaired normally however far the minimum climbs afterwards. Anybody invoking a standards change to argue that a working system must be replaced is selling rather than advising, and the argument has no legal content behind it.

Where the floor does reach an existing owner is model continuity. Ranges are withdrawn rather than re-rated when a threshold moves, and the ones withdrawn are those nearest the old minimum. That surfaces years later as a discontinued range and a longer wait on a control board, which is a parts question rather than a compliance one.

Efficiency is one input among several, and it is rarely the input that goes wrong. Capacity matched to the room, a condenser sited where it can actually reject heat, and an installation done properly move a running bill further than a step inside a single band. The aircon buying checklist covers that ground. This page settles a narrower thing: what the bottom of the scale means, and why it is not where it used to be.

  • Ask which efficiency figure the model measures, not how many ticks it carries. The band confirms it cleared. The figure says by how much.
  • Ask whether the exact model quoted is currently registered. Registration runs per model and has to be live for the machine to be supplied.
  • Treat any tick claim in older material as undated until checked against what that format's bands are today.
  • On a system 2, 3 or 4, set the tick count aside as a comparison tool. Every option in front of you carries the same one.
  • If a retailer cannot produce the efficiency figure behind the band, the shortlist has been described rather than narrowed.