MELS Explained: What the Energy Label Is Required to Show

The label fixed to a showroom condenser and the poster above it read as one message. The label is prescribed by regulation and checkable on a public register. The poster is the seller's own composition.

On this page

Quick summary

MELS is NEA's mandatory energy label: every field is prescribed, the model is registered, and registered models are retested against what they declared. MEPS is the separate floor below which a model cannot be supplied. A showroom poster carries no such duty, so read the label on the outdoor unit and check its registration number.

MELS is an obligation on the supplier

The Mandatory Energy Labelling Scheme lets buyers compare the tested efficiency of regulated goods. Aircon came under it on 1 January 2008, alongside refrigerators.

Two registrations sit behind it. An importer or manufacturer first registers as a supplier, then registers each model before supplying it. A registered supplier must affix the label to every unit it supplies, and retailers may display only models that carry one.

Scope follows machine type, not brand or price. Single-phase non-ducted room air-conditioners and portable air-conditioners are separate entries, with three-phase VRF separate again. Household splits sit in the first.

Registration expires, and the label rides on it

NEA's certificate for each model runs three years. A supplier renews it in a window from ninety days to at least two weeks before expiry. The printed registration number records a certificate live when the label was printed, which is weaker than live today. The QR code opens the Database of Registered Goods, so the check is a lookup.

What the label is required to carry

Every field is prescribed. The fields are brand, nameplate model number, type and size. They also cover tick rating and its wording, annual energy cost and consumption, test standard, disclaimer, registration number and QR code.

Size is the full load cooling capacity in kW, to two decimal places, traced to the registration test report. Where a quotation's horsepower and the label disagree, the label was tested.

The word beside the ticks is fixed: one tick Low, two Fair, three Good, four Very Good, five Excellent. A brochure's adjective is the seller's own claim.

Annual cost assumes eight hours of use and sixteen of standby daily at 27 cents per kWh. It compares two labels on identical terms and does not predict a household bill.

What the label is required to carry summary table
Field on the labelWhere it comes fromWhat it does not settle
Brand, model and typeThe nameplate, as registered with NEAWhether the model quoted is the model delivered
Size in kWFull load cooling capacity from the test reportWhether that capacity suits the room
Ticks, and the rating wordThe band the tested figure landed inWhere inside that band the model sits
Annual cost and annual kWhEight hours of use, sixteen of standby, 27 cents per kWhWhat the machine will cost in your flat
Registration number and QR codeThe certificate NEA issued for that modelAnything about installation or after-sales support

Even the label's shape is specified

NEA sets the label at nine centimetres square, in bold black Arial, printed indelibly at no less than 300 pixels per inch on approved material. A redrawn label is not the instrument.

On a split system the label goes on the outdoor unit only. A showroom displaying the indoor unit alone must show the labels for every outdoor unit that can pair with it. A tick count on the wall belongs to a pairing, not the box in front of you.

MELS and MEPS: disclosure and prohibition

MELS compels disclosure. Minimum energy performance standards (MEPS) raise average efficiency by barring any model below a set level. One makes a model declare where it stands, and the other decides whether it may stand there at all.

The order is floor first. A model clears the standard, then is registered, then gets a label. A seller who says a model meets the national standard names an entry condition, since a model that failed it could not lawfully be on the floor. Pointing at the label is a different act and a checkable one.

The tick bands describe efficiency and the floor decides which bands still hold products. The MEPS floor guide covers which bands survive today, and the tick rating guide reads the ticks on their own terms.

Why the regulated half can be checked

NEA carries out verification testing on registered models from time to time. For aircon, the COP from the verification test must exceed 0.9 times the COP in the test report. A declared figure has to survive a retest within a tenth of itself. Brochures, flyers and a salesperson's summary carry no such retest.

Advertising is the one place the duty follows the label off the unit. NEA requires a legible energy label beside the image or description of a regulated good. Where there is no room, the tick rating and registration number must be stated prominently. A listing with neither is short of what the rule asks.

Registration runs per model. If the quotation's model string differs from the label's, the near match is a different registration or none. Ask for the label of the unit you will receive and read the registration number off it.

Using the label at the point of purchase

The label settles identity, tested capacity, efficiency band and registration. It says nothing about who installs the unit or who honours the warranty. It does not say whether a control board can be found when one fails. It does not say whether the capacity fits the room, or whether the outdoor unit has somewhere to reject heat. The aircon buying checklist covers that ground. Confirm in writing who installs it and who handles warranty claims.

  • Photograph the label, not the display board, and ask to see the outdoor unit on a split system.
  • Read capacity in kW off the label before accepting a horsepower figure.
  • Check the registration number in the Database of Registered Goods. NEA tells buyers to buy only registered appliances.
  • Treat annual cost as a yardstick. Your hours are not the label's hours.
  • When two shortlisted models share a band, the ticks no longer separate them. The CSPF guide covers the figure underneath.
Using the label at the point of purchase summary table
What you are shownWho is obliged to make it trueHow to settle it where you stand
A tick count on a display boardNobody, unless the board reproduces the labelFind the label on the unit and read the ticks off that
A model number on a quotationThe seller, under the contract you signMatch it character for character against the label
The energy label on the outdoor unitThe registered supplier, under MELSScan the QR code, or check the registration number
An annual running costNEA, on its own fixed assumptionsRead it as a comparison figure, never as a forecast
A spoken efficiency claimNobodyAsk for the tested figure sitting behind the band

Common questions

What is the difference between MELS and MEPS?
MELS makes a supplier disclose a model's tested efficiency on a prescribed label. MEPS sets the floor below which a model cannot be supplied at all.
Where does the energy label sit on a split system?
On the outdoor unit. Where a showroom displays only the indoor unit, it must show the labels for every outdoor unit that can pair with it.
How can I check that a model is registered?
Scan the QR code on the label or search the registration number in the Database of Registered Goods. NEA advises buying only registered appliances.
Is the annual energy cost on the label my actual bill?
It is a standard estimate so buyers can compare models. Your bill depends on how long you run the aircon and the tariff you pay.