Midea MEZ-3M28E (6.64 kW, COP 5.13/5.98, S$669 yearly) delivers higher efficiency than MEZ-4M32E (7.23 kW, COP 4.74/5.63, S$779 yearly). Choose MEZ-3M28E for 3-room flats or bedroom-only 4-room HDB setups, and upgrade only when cooling a fourth space.

On this page

Efficiency trade-off between MEZ-3M28E and MEZ-4M32E

According to NEA 5-tick filings on 21 November 2026, dropping from four ports to three gives Midea MEZ-3M28E a clear efficiency jump. Its 5.98 part-load COP and 5.13 full-load COP outpace MEZ-4M32E (5.63 and 4.74), trimming estimated yearly electricity charges by S$110 on NEA's standard usage formula.

MEZ-4M32E adds only 0.59 kW of total condenser capacity (7.23 kW against 6.64 kW) to serve an extra indoor fan coil. That modest headroom works well when bedrooms run at night and the hall runs during the day, rather than blasting all four blowers nonstop.

Efficiency trade-off between MEZ-3M28E and MEZ-4M32E summary table
SpecificationMidea MEZ-3M28E (System 3)Midea MEZ-4M32E (System 4)
Cooling capacity6.64 kW7.23 kW
Full / part-load COP5.13 / 5.984.74 / 5.63
NEA annual energy costS$669S$779
Typical HDB match3-room flat or 3 bedrooms4-room flat with hall FCU

Room combinations for 3-room and 4-room HDB layouts

In a 3-room HDB flat (two bedrooms plus living area), MEZ-3M28E hits the sweet spot: enough capacity for a 12,000 or 18,000 BTU hall blower alongside two 9,000 BTU bedroom units without overspending on an unused fourth port.

For 4-room BTO or resale flats, families who rely on ceiling fans in the living room save on upfront hardware, trunking length, and routine quarterly servicing by installing MEZ-3M28E across the three bedrooms alone.

HDB electrical loading and installation planning

Both condensers fit standard HDB aircon ledges when installed by BCA-trained installers following HDB bracket and safety rules, and older flats with 30A main switches should have electrical loading verified prior to adding a fourth blower. Never oversize pipe runs without confirming condensate drain falls back to the bathroom or kitchen floor trap.

Drop your flat floor plan to Snowflake Aircon Services over WhatsApp so a technician can review pipe routing, ledge fit, and the right FCU mix.

Common questions

Can Midea MEZ-3M28E cool a 4-room HDB flat comfortably?
Midea MEZ-3M28E cools three bedrooms in a 4-room HDB flat easily because its 6.64 kW output and 5.98 part-load COP handle three 9,000 BTU bedroom units with strong efficiency. Households wanting a fourth indoor unit in the living hall must move up to a System 4 condenser.
Why is MEZ-3M28E noticeably more efficient than MEZ-4M32E on NEA ratings?
MEZ-3M28E achieves 5.13 full-load COP and 5.98 part-load COP versus 4.74 and 5.63 on MEZ-4M32E because its compressor and heat exchanger operate closer to peak thermodynamic balance at 6.64 kW. That reduces estimated NEA yearly power spend from S$779 down to S$669.
Does running three bedrooms on MEZ-4M32E waste electricity compared with MEZ-3M28E?
Running three bedrooms on MEZ-4M32E consumes slightly more electricity than MEZ-3M28E because its part-load COP drops from 5.98 to 5.63. Paying for a fourth port makes financial sense mainly when the living room blower will run regularly during hot afternoons or family visits.
Can a fourth indoor blower be added later to a Midea MEZ-3M28E condenser?
Adding a fourth indoor unit later to MEZ-3M28E is impossible because the outdoor condenser physically contains only three refrigerant pipe ports and matching expansion valves. Homeowners expecting future living-room cooling should either install System 4 upfront or reserve space for a separate single-split unit.