Mitsubishi Electric MXY-4H38VG vs MXY-5H48VG Comparison

Mitsubishi Electric MXY-4H38VG supplies 8.05 kW across four circuits (weighted COP 6.19, S$790/yr). Stepping up to five-port MXY-5H48VG raises cooling capacity to 9.10 kW (weighted COP 6.07, S$918/yr) for bigger 5-room flats and large condos.

On this page

Cooling output and NEA running numbers side by side

Both Starmex flagship condensers earn 5-tick R32 certification, yet they serve notably different room counts and electrical budgets. Official NEA entries reviewed on 21 Nov 2026 show MXY-4H38VG achieving a standout 6.19 weighted COP while MXY-5H48VG adds an extra 1.05 kW of total cooling ceiling plus a fifth refrigerant port.

That extra capacity pushes MXY-5H48VG's annual test consumption from 2,926 kWh to 3,399 kWh, translating to S$128 more per year under standardised NEA billing assumptions.

Cooling output and NEA running numbers side by side summary table
SpecificationMXY-4H38VG (4-port)MXY-5H48VG (5-port)
Cooling capacity8.05 kW9.10 kW
Full / weighted COP4.97 / 6.194.87 / 6.07
Annual energy usage2,926 kWh/yr3,399 kWh/yr
Estimated yearly billS$790/yrS$918/yr

Choosing between four ports, five ports, and two separate condensers

Standard 5-room HDB layouts with three bedrooms and one living-dining area fit cleanly on MXY-4H38VG, giving strong simultaneous cooling without paying for a fifth unused circuit. MXY-5H48VG makes sense when a flat adds a partitioned study, helper room, or twin hall blowers on a single condo ledge where only one compressor chassis can physically sit.

However, concentrating five rooms onto one MXY-5H48VG chassis creates a single point of failure. If an outdoor inverter board faults later and requires full PCB replacement, all five zones lose cooling at once. Where ledge width and MCST bylaws allow, splitting loads into a System 3 plus System 2 preserves redundancy.

Verifying ledge weight, exhaust space, and current limits

Large multi-port condensers pull higher maximum amps and discharge substantial heat into semi-enclosed condo AC ledges or HDB service yards. Confirm your flat's approved electrical loading and ensure front louvres allow unobstructed hot-air exit so high-pressure trips never occur on humid nights.

Contact Snowflake Aircon Services directly through WhatsApp with your condo layout or HDB electrical details for a candid capacity, redundancy, and ledge-clearance check.

Common questions

Can a standard 5-room HDB flat legally install Mitsubishi Electric MXY-5H48VG?
Approval depends on each HDB block's electrical supply upgrade status, maximum permitted running current, and physical ledge footprint. Many newer 5-room flats comfortably fit four-port MXY-4H38VG, whereas five-port MXY-5H48VG requires checking total current draw and bracket clearance against current HDB installation guidelines before ordering.
Why does MXY-4H38VG have a higher weighted COP than MXY-5H48VG?
Mitsubishi Electric MXY-4H38VG posts a 6.19 weighted COP and 4.97 full-load COP compared with 6.07 and 4.87 on MXY-5H48VG because the four-port compressor operates in a tighter, highly tuned part-load band. For four-room households, MXY-4H38VG avoids unnecessary standby capacity overhead.
Is one MXY-5H48VG better than installing a System 3 plus System 2 in a big condo?
Single-chassis MXY-5H48VG saves aircon ledge real estate and requires only one isolator point when condo ledges are cramped. Where two condensers fit legally, a System 3 plus System 2 delivers higher combined cooling capacity and guarantees that half the home keeps cooling if one outdoor unit needs servicing.