Leading 5-tick System 2 and System 3 NEA specs
Figures published on NEA's energy register on 21 Nov 2026 show tight competition among Japanese and Korean multi-split condensers designed for 2-room Flexi, 3-room HDB flats, and compact condo units.
System 3 models span 5.88 kW to 6.91 kW in rated cooling, while System 2 condensers cluster between 4.15 kW and 4.58 kW with annual label estimates staying around S$401 to S$454.
Scroll to see more columns
| Type & outdoor model | Rated cooling | Full / part-load COP | NEA yearly cost |
|---|---|---|---|
| System 3: Fujitsu AOAH24CBTA3 | 6.17 kW | 5.44 / 6.22 | S$576 |
| System 3: Daikin MKP75VVMG | 6.15 kW | 5.61 / 6.14 | S$576 |
| System 3: Daikin MKM75ZVMG | 6.07 kW | 5.53 / 6.11 | S$571 |
| System 3: MHI SCM60YS-W | 5.88 kW | 4.94 / 6.09 | S$593 |
| System 3: Mitsubishi Electric MXY-3H28VG2 | 6.45 kW | 4.86 / 6.07 | S$645 |
| System 3: Mitsubishi Electric MXY-3H28VG | 6.56 kW | 4.89 / 6.05 | S$653 |
| System 3: LG Z3UQ28GFA1 | 6.91 kW | 4.95 / 6.04 | S$692 |
| System 2: LG Z2UQ18GFA1 | 4.58 kW | 5.08 / 6.09 | S$453 |
| System 2: Daikin MKM50ZVMG | 4.15 kW | 5.33 / 6.01 | S$401 |
| System 2: Panasonic CU-2XU20YBZ | 4.47 kW | 4.95 / 5.99 | S$454 |
Choosing between higher COP and higher cooling reserve
Fujitsu AOAH24CBTA3 and Daikin MKM75ZVMG excel when cooling three standard bedrooms where peak heat loads stay predictable. Their strong full-load COP values above 5.40 keep utility bills lean even on humid nights when all three indoor units operate simultaneously.
Flats combining two bedrooms with an open living hall often benefit from the extra headroom of LG Z3UQ28GFA1 at 6.91 kW or Mitsubishi Electric MXY-3H28VG at 6.56 kW. That extra capacity lets an 18,000 BTU living-room fan coil pull down afternoon heat faster.
HDB installation checks for System 2 and System 3
Older 3-room flats sometimes retain smaller electrical isolators or narrower outdoor brackets that limit condenser weight and current draw. Checking HDB electrical load allowance alongside trunking routing avoids unexpected rewiring during replacement day.
WhatsApp your room count, living-room cooling plan, and existing condenser photo to Snowflake Aircon Services so our team can quote an accurately sized 5-tick System 2 or System 3 installation.
Common questions
Which System 3 condenser has the lowest NEA annual electricity estimate?
How does Mitsubishi Electric MXY-3H28VG2 differ from MXY-3H28VG?
Can a 5-tick System 2 aircon cool a bedroom and a living room together?
Does Mitsubishi Heavy Industries SCM60YS-W suit a 3-room BTO flat?