Quietest Wall-Mounted Aircon for Bedrooms by Sound Level

The quietest settings of the main brands sit within a decibel or two of each other. Once the spec sheets are lined up, a bedroom unit's noise depends more on its installation and its upkeep than on the brand.

On this page

Which wall-mounted aircon is quietest?

Daikin, Mitsubishi Electric and Mitsubishi Heavy Industries each list 19 dB(A) as the lowest fan-speed level of their quietest 9,000 BTU indoor units. At 12,000 BTU the figures run 19 to 20 dB(A).

That is a test-chamber figure at the lowest fan speed. The gap between the brands is too small to hear.

Scroll to see more columns

Which wall-mounted aircon is quietest? summary table
RankBrandIndoor modelMaker's rated sizeLowest fan speedType
1DaikinFTKM25ZVMG9,000 BTU (2.5 kW)19 dB(A)Single split
1DaikinCTKM25ZVMG9,000 BTU (2.5 kW)19 dB(A)Multi-split indoor unit
1Mitsubishi ElectricMSXY-FP10VG9,000 BTU (2.8 kW)19 dB(A)Multi-split indoor unit
1Mitsubishi Heavy IndustriesSRK10YYS-W9,000 BTU (2.8 kW)19 dB(A)Single split
1Mitsubishi ElectricMSXY-FP13VG12,000 BTU (3.5 kW)19 dB(A)Multi-split indoor unit
1Mitsubishi Heavy IndustriesSRK13YYS-W12,000 BTU (3.6 kW)19 dB(A)Single split
1DaikinCTKM35ZVMG12,000 BTU class (3.5 kW)19 dB(A)Multi-split indoor unit
8DaikinFTKM35ZVMG12,000 BTU (3.2 kW)20 dB(A)Single split

How the list was built

Each figure is the maker's published indoor sound level at the lowest fan speed, from its own product page or catalogue, read on 20 November 2026. Sizes are the makers' ratings. Mitsubishi Heavy Industries' figures come from its 2023 Asia catalogue; the matching outdoor units are on NEA's register. Ties share a rank.

Brands not in the list

Panasonic, Samsung, Midea and LG are not ranked. No Singapore page or sheet with a comparable lowest-speed figure was found for them.

Why a quiet unit can still be noisy

The published figure is for a clean unit at its lowest speed. A clogged filter or a dirty blower makes the fan work harder, and that noise does not show on any sheet.

Installation matters as much. A unit that is not level, a loose panel or trunking that touches the wall can rattle at any speed.

  • Ask for the unit to be mounted level and clear of the bed's headboard.
  • Use the quiet or night fan setting while sleeping.
  • Have the filters cleaned at every servicing; airflow noise rises as they block.
  • Service the unit before the blower builds up dirt.

Picking a bedroom unit once noise is a tie

Since the quietest settings are level, choose on sizing, efficiency and after-sales support. Ask for the unit size to be worked out for the room rather than picked by habit.

Snowflake's standard bedroom unit is Mitsubishi Electric Starmex.

Common questions

What is the quietest aircon for a bedroom in Singapore?
Daikin, Mitsubishi Electric and Mitsubishi Heavy Industries each list 19 dB(A) at the lowest fan speed for their quietest 9,000 BTU wall-mounted indoor units. The difference between them is too small to hear, so a bedroom aircon is better chosen on size, efficiency and support.
How many decibels is a quiet aircon?
A quiet wall-mounted aircon indoor unit is rated at about 19 to 20 dB(A) at its lowest fan speed by the main brands sold in Singapore. That figure is for a clean unit on its quietest setting. The same unit is louder at higher fan speeds and when its filter or blower is dirty.
Why is my new aircon noisy at night?
A new aircon that is noisy at night is often running at a high fan speed, mounted slightly off level, or touching loose trunking or a panel that rattles. A dirty filter adds airflow noise as well. A technician can check the mounting, the panel and the fan settings in one visit.
Where should a bedroom aircon be mounted to keep it quiet?
A bedroom aircon is best mounted level, on a wall that does not share the headboard, and aimed so the airflow does not blow straight onto the bed. A level unit with its trunking fixed firmly is less likely to rattle, and a clear path for the air lets the fan run at a lower speed.