R22 Aircon with a Gas Leak: Repair It or Replace the System

Most R22 aircons still running are old, and their gas is being phased out. A leak forces the question early: one more repair on a shrinking supply of gas, or a new system on current refrigerant.

On this page

Repair or replace an R22 aircon with a leak?

Replace it when the leak is in a coil or keeps returning. Repair it only when the leak is at an accessible joint and the rest of the unit is sound, because R22 supply is being cut each year.

Singapore must phase out HCFCs such as R22 by 1 January 2030, with import quotas cut every year from 2026. Existing R22 units may still be serviced, but the gas will get scarcer.

R22 aircon with a leak: repair or replace
OptionMarket range in SingaporeOur rate
Leak test to find the leak$50–$180 per jobQuoted per job
R22 gas after the leak is sealed$60–$100
Coil replaced, if the leak is in the coil$200–$1,800 per job
Replace with a new System 2, any brand$1,400–$5,200 per job$2,600

A leak at a joint is the cheapest repair; a coil leak on an R22 unit is usually the point to replace. New systems run on R32, so old R22 piping is reused only after checks.

Market ranges: published rates from 4 Singapore operators. Checked between 18 Nov 2026 and 20 Nov 2026.

Our rates are from our rate card.

When an R22 repair still makes sense

Have the leak located and sealed before any gas goes in. Topping up R22 into a leaking circuit spends a shrinking resource on gas that escapes again.

  • The leak is at a flare joint or valve that can be remade on the visit.
  • The compressor and coils are sound, and cooling was good before the leak.
  • You plan to replace the system within a year or two anyway, and need it to last until then.

Why replacement usually wins

Most R22 systems still in use are old, so the coils, compressor and board have all aged together. A coil repair puts money into one old part of an old system.

A new system runs on current refrigerant, which keeps future gas repairs simple to source.

What happens to the old piping

Old R22 piping can sometimes be reused for an R32 system, but only after it is checked, cleaned where needed and pressure tested. Many replacements lay new piping instead.

The old R22 should be recovered from the system before it is removed, not released.

Common questions

Is R22 aircon gas still available in Singapore?
Yes, for now. NEA is phasing out the supply of R22 and other HCFCs, with import quotas cut every year from 2026 and a complete phase-out by 1 January 2030. Existing R22 aircons are not required to be replaced, but the gas for servicing them will become scarcer each year.
Should I repair an R22 aircon with a gas leak?
Repair an R22 aircon only if the leak is at an accessible joint, the rest of the unit is sound, and you need it to last a short while longer. A coil leak or a repeat leak on an R22 system is usually the point to replace it with a new system on current refrigerant.
Do I have to replace my R22 aircon by 2030?
No. NEA's phase-out controls the supply of R22, not the use of existing equipment, and NEA's 2012 circular states there is no requirement to replace existing HCFC-based equipment. The practical limit is that R22 for repairs will become harder to get as quotas shrink.
Can R22 piping be reused for a new R32 aircon?
Sometimes. Old R22 piping can be reused for an R32 aircon if its size and thickness suit the new unit, the flares are remade, the pipes are cleaned of old oil where needed and the run holds an airtight test. The new unit's installation manual sets the conditions.