Keep, service or replace the old aircon?
Keep and service it if it cools well and an inspection finds nothing failing. A working R22 unit can be kept too; the decision on it comes when its gas circuit has to be opened, because R22 is being phased out.
If it falls in between, Snowflake Aircon Services' view is to service it and plan the replacement. Replacing a working system on moving day rarely pays.
| Option | Market range in Singapore | Our rate |
|---|---|---|
| Pre-move-in inspection of the system | $30 / visit | |
| Keep it: chemical servicing per wall-mounted unit | $80 for one unit; $70 each for two; $60 each for three or more | |
| Keep it: chemical overhaul per wall-mounted unit, if heavily fouled | $150 for one unit; $125 each for two; $115 each for three or more | |
| Replace it: System 3 supply and install, any brand | $1,800–$7,000 per job | $3,750 |
The inspection fee is waived if you go ahead with the servicing or repair quoted after it.
Market ranges: published rates from 4 Singapore operators. Checked 20 Nov 2026.
| What you find | Usual call | Why |
|---|---|---|
| Cools well, recent model, clean inspection | Keep; general service before moving in | A sound system only needs a clean |
| Cools well but heavily fouled | Keep; chemical service or overhaul | Deep dirt, not a fault |
| Runs on R22 and works | Keep; plan to replace when it needs gas work | R22 is being phased out by 2030 |
| Repeated gas top-ups by the seller | Leak test, then likely replace | A leak was never fixed |
| Compressor or coil failing | Compare the repair with a new system | The costliest parts of an old system |
Check before the keys change hands
Warranty transfer depends on the brand. Daikin's warranty follows the installation address and product, while Samsung's and Midea's are not transferable. Ask the seller for the warranty certificate and check the brand's terms.
- Read every model sticker for the brand, model and refrigerant.
- Ask the seller for servicing records and any repair invoices.
- Run every unit for ten minutes and feel for cold air.
- Look for water stains under each indoor unit.
- Check the outdoor ledge is clear and the units sit level.
Why servicing comes first
A resale system's history is unknown, and a fouled coil can look like a fault. A chemical service before moving in shows how the system really performs, often for far less than a replacement.
If you do replace, do it during renovation, while the walls and trunking can still be changed.