Quick summary
York's blink table covers the P Series ductless family only. Count one full repeat of the indoor lamp, then confirm over a second; the outdoor lamps are for the technician to read on site. Singapore YHFF R32 high-wall units show an FC filter reminder, which is not a fault.
What Each York Lamp Does
P Series indoor units name the reporting lamp in the fault table: running, cooling or heating. The outdoor unit has its own set of lamps, which the technician reads on site. Lamp colours and positions vary by model, so confirm yours before counting.
| Lamp | Where | What it counts |
|---|---|---|
| Running lamp | Indoor panel | E-series faults and some H-series rows |
| Cooling lamp | Indoor panel | F-series sensor faults |
| Heating lamp | Indoor panel | H-series compressor and defrost rows |
| Red lamp | Outdoor unit | Outdoor protection and sensor faults |
| Yellow lamp | Outdoor unit | Outdoor faults and protections |
| Green lamp | Outdoor unit | Communication state; unlit when the link fails |
| Display (YHFF R32) | Indoor panel | FC filter reminder; no service blink table |
Normal York Lamp States and Protective Stops
H1 is defrosting and Fo is gathering refrigerant, both normal operating states. FC is a filter reminder, not a fault.
Protective stops are different. E2 is anti-freezing protection and H3 is compressor overload protection. The unit stopped to protect the compressor rather than to report a failed part.
A protective pause can follow power restoration while the system settles. Watch the lamps during that window, because the count still records the fault.
York Blink Patterns and the Codes Behind Them
Read the indoor lamp; the outdoor lamp confirms it when the technician attends. The table lists the common P Series rows. The York error code list holds a page for each fault code above, and the P Series technical guide carries the full lamp table.
| Indoor lamp | Outdoor lamp | Code and meaning |
|---|---|---|
| Running 2 blinks | Yellow 3 blinks | E2 anti-freezing protection |
| Running 3 blinks | Red 9 blinks | E3 refrigerant block or low pressure |
| Running 4 blinks | Yellow 7 blinks | E4 compressor exhaust high temperature |
| Running 6 blinks | Green off | E6 indoor-outdoor communication failure |
| Cooling 1 blink | None | F1 indoor ambient sensor open or short |
| Cooling 2 blinks | None | F2 indoor tube sensor open or short |
| Cooling 3 blinks | Red 6 blinks | F3 outdoor ambient sensor open or short |
| Heating 1 blink | Yellow 2 blinks | H1 defrosting, a normal state |
| Running 11 blinks | None | H6 no feedback from the indoor fan motor |
| Running 23 blinks | Red 14 blinks | L3 outdoor DC fan motor malfunction |
| Display | None | FC filter reminder, maintenance only |
How to Read a York Fault Code from the Blink Count
Watch the lamp named in the table and count the blinks in one full repeat, then confirm over a second repeat. Counting a single burst is the usual source of a wrong code. On a multi-head system, read each indoor lamp separately.
The P Series table covers the ductless models in its own guide. For a Singapore YHFF R32 high-wall unit, the official manual documents the FC filter reminder only, so confirm the model sticker and use York support beyond that.
The outdoor lamp confirms the indoor reading in most rows. A green outdoor lamp that stays off usually means the communication link has failed.
York Systems with More Than One Indoor Unit
On a multi-split or Mini VRF system, alarms can appear on the outdoor board or wired controller as numeric codes instead of lamp counts. Check each indoor unit in turn as well.
If every unit stops together, the likely source is the outdoor plant or the line that links the heads. If one unit shows a fault while the others run, the fault sits at that unit.
Send the number of affected units first. It decides whether the visit covers one head or the shared outdoor plant.