Summary
Do not keep resetting a breaker that trips in wet weather. It is isolating a circuit where water and electricity are meeting. Leave it off and have the isolator checked.
Likely Causes
- A perished isolator seal lets rainwater into the switch box.
- A cable entry never sealed at installation admits water in sustained rain.
- A loose terminal fails once humidity rises, with no water present.

Quick Fault Summary
| Likely cause | What to check | Typical next step |
|---|---|---|
| Perished seal on the isolator box | It only trips during or just after heavy rain. | A technician opens and dries the isolator, replaces the seal and any corroded terminals, and checks the connection before restoring power. |
| Cable entry never sealed at installation | The trips started early in the installation's life. | A technician fits a proper gland and seal at the cable entry, dries the enclosure and checks the route so water runs away from the box, not along the cable into it. |
| A loose terminal that fails once humidity rises | It sometimes trips on very humid days with no rain at all. | A technician opens the box to confirm it is dry, then checks and retorques every terminal and replaces any with heat damage before restoring power. |
- Likely cause
- Perished seal on the isolator box
- What to check
- It only trips during or just after heavy rain.
- Typical next step
- A technician opens and dries the isolator, replaces the seal and any corroded terminals, and checks the connection before restoring power.
- Likely cause
- Cable entry never sealed at installation
- What to check
- The trips started early in the installation's life.
- Typical next step
- A technician fits a proper gland and seal at the cable entry, dries the enclosure and checks the route so water runs away from the box, not along the cable into it.
- Likely cause
- A loose terminal that fails once humidity rises
- What to check
- It sometimes trips on very humid days with no rain at all.
- Typical next step
- A technician opens the box to confirm it is dry, then checks and retorques every terminal and replaces any with heat damage before restoring power.
1. Perished Seal on the Isolator Box
Tripping that began after years of reliable service on an older installation usually means the isolator seal has perished. Water runs along the cable into the box and pools on live terminals until the breaker cuts the circuit.
How to Tell
Age is the marker: this one worked for years before it started, while a missing grommet fails early.
- It only trips during or just after heavy rain.
- The installation is old and worked reliably for years.
- It works normally again once everything dries out.
- The isolator box outside looks weathered or cracked.
How We Confirm It
A technician opens and dries the isolator, replaces the seal and any corroded terminals, and checks the connection before restoring power.
Never keep resetting the breaker after a rain-linked trip. Each reset re-energises terminals with standing water on them.
Related Cases
2. Cable Entry Never Sealed at Installation
Wet-weather tripping present since early in the installation's life points to a cable entry that was never sealed, with no grommet or gland fitted. Only sustained rain drives enough water along the cable to reach the terminals.
How to Tell
Trips began early because the entry has no gland at all, and water is getting inside.
- The trips started early in the installation's life.
- Only long, sustained downpours set it off, not brief showers.
- The cable enters the box without any visible grommet or gland.
- Everything works normally in dry weather.
How We Confirm It
A technician fits a proper gland and seal at the cable entry, dries the enclosure and checks the route so water runs away from the box, not along the cable into it.
A tape or filler patch on a cable entry fails and the water returns. The entry needs a proper gland.
Related Cases
3. A Loose Terminal That Fails Once Humidity Rises
Tripping in wet weather with a dry box inside means the connection itself is marginal. A loosened terminal still carries current on dry days, then heats and arcs once humidity rises.
How to Tell
Humid days with no rain set it off, often with a scorched smell at the switch, so neither sealing fault applies.
- It sometimes trips on very humid days with no rain at all.
- No water or wet staining is visible around the outdoor switch.
- A scorched or acrid smell hangs around the outdoor switch.
- Trips have been getting more frequent.
How We Confirm It
A technician opens the box to confirm it is dry, then checks and retorques every terminal and replaces any with heat damage before restoring power.
Stop using the aircon if anything smells scorched near the switch, and leave the circuit off. Arcing at a loose contact damages the enclosure around it.