An aircon that ignores its remote can need a new handset, a receiver repair or a fix to the indoor supply or board. We test where the signal stops before quoting a part.

Message us on WhatsApp

On-site check: $30 / visit. Visit fee waived if you proceed with the quoted work.

On this page

Signs to Check the Remote and IR Receiver

  • The Remote Display Works but the Unit Does Not Respond

    The handset may not transmit, the signal may be blocked, or the indoor receiver and control path may be offline.
  • Only Some Buttons or Commands Work

    Worn handset contacts, wrong mode, model incompatibility or a receiver issue can produce partial response.
  • The Indoor Display Is Blank as Well

    Missing indoor power, a fuse, connector, display board or main PCB may be responsible rather than the remote.

Service Scope

  • Check whether your remote sends a signal

    We check batteries, contacts, buttons and settings, then test whether the handset sends an infrared signal.

  • Find where the signal stops

    We check power to the receiver, its connector and wiring, then test whether the display and indoor board respond to the command.

  • Confirm the aircon responds again

    If a new handset, receiver or display board is needed, we quote the matching part and test normal commands after fitting it.

What It Costs

Infrared Receiver Repair

Infrared receiver repair rates
ItemPrice
Sensor / IR receiver$120–$150

This range applies to confirmed sensor or infrared receiver repairs on wall-mounted units. We check the remote and the indoor controls before quoting.

Rates as of 20 Nov 2026.

Workmanship Warranty

Labour

30-day workmanship warranty. If the same fault returns from our repair, we come back and the labour is on us, with no second on-site check fee.

Parts

Parts carry the distributor's warranty for that component, so the term varies by part. We tell you both terms before you approve the work.

Photos from Recent Jobs

What Customers Say

  • “Great people and process. Booked their $30 check when my air conditioner could not switch on. They traced the problem to wiring. No upsell, no drama. Repair done same day, check fee waived. Everything upfront, no hidden cost. Definitely would use their services again! 5/5”
    Yong Jun YeoGoogle
  • “The installer for my new aircon had done a brillant job and the communication had been seamless as well. I am happy in engaging their service!😄”
    cz0903Carousell
  • “Repeated the chemical wash today. Their professional team made sure there was minimal mess and dirt during the process. Can really feel the difference, the aircon feels much better after the servicing. Very satisfied with their service!”
    jonathan limGoogle
  • “they are amazingly on time, and very upfront on the prices. Friendly disposition and they provided valuable advices. i like how that they only sell what you need. Just awesome!”
    makchique_specsCarousell
  • “Customer service was prompt and responsive throughout. Guys came on time, helped to advise on the proper cleaning and relocation, even helped me to save money. Highly recommended!”
    A NGoogle
  • “The guys at Snowflake go above & beyond in terms of customer service. I had contacted them due to my aircon unit leaking. The guys spent an hour doing chemical clean. However my unit starting leaking again that night. Snowflake were extremely proactive by sending same guys next guy to fix the problem. They located pipe outside & cleared it. Really highly recommend 👍🏼🤩”
    nazzasgCarousell
  • “For our 1 year contract, we are satisfied with the efficiency and skilled of the technicians who maintained our aircon. Easy to schedule and coordinate. Hence, we will re contract for another year. Thanks for your service.”
    Marian ArcaoGoogle
  • “Fast and efficient service! 100% satisfied with the fast work! Arrived on time and work done was very professional for our commercial unit! Even provide us with new controller (at a price) cause ours didnt work anymore! 😔”
    baecaresgCarousell
  • “Used them a few times, very pleased with service level and prices. They provide honest advice on what is needed or not. Plus, they always bring a tarp to cover surfaces. No dodgy upselling practices. Recommended. Will continue to engage their service.”
    HW LGoogle
  • “Angeline is very patient in answering all my queries via chat. Tony came to check and does the necessary and give really good recommendation and advices on what is really needed to be done. Recommended 👍”
    lill.yCarousell
  • “Excellent Experience Installing System 3 Air Conditioner Knowledgeable, flexible, and efficient service.”
    David NgGoogle
  • “Excellent service, able to solve our problem with the aircon removal professionally and goes the extra mile to help us! Would recommend 101%! 💯💯”
    kullookCarousell
  • “Mr Yi Tat & Mr Kian were very efficient at servicing 4 ACs within 2 hours! They were very friendly and extremely easy to communicate with throughout the process. Will definitely call them back for future servicing. Thank you, gentlemen!”
    Murshidah MunibGoogle
  • “Engaged them because of good reviews and truly they deserved the good reviews. Tony and Ian were able to rectify my problems (other technician was not able to pin point the fault). Repaired and service with resonable charges. Thanks Tony and Ian for solving my issue. 🙏”
    ngeokhimCarousell
  • “My go to Aircon servicing for years on. Always prompt in responses and punctual on day if servicing. If delays are expected, they will update via WhatsApp. Never upsell and is honest and dependable. I always have Yen for my servicing. great guy!”
    Joanne CGoogle
  • “Technician came within the time frame that they provided and the technician even go extra miles in cleaning and wiping the surrounding areas after chemical wash. Servicing is indeed good”
    SharonnczyCarousell
  • “The technician explained their solution thoroughly and their price is transparent. Recommended”
    Zi Hao TanGoogle
  • “trusted,easy&fast reply..e service was excellent..e servicing man advice abt my aircon..no messy dust..👍 now my 3 unit aircon getting much colder...tqsm..(will deal wif u again)❤”
    idaomrsleeCarousell
  • “Great service! The response was very fast and they arranged the repair quickly. The technician was experienced and knew exactly what to do. Everything was fixed efficiently and the pricing was very reasonable. Definitely value for money—highly recommended!”
    Alex LuGoogle
  • “Thumbs up for snowflake aircon service. Delayed a bit on the arrival but they are able to inform prehand. Their guys are very professional to recommend what's the best solution for me. Reasonable price with quality work. Will surely engage them again :)”
    ivanaviCarousell
  • “My family has been going back to them for 10 years+. Service is always amazing and the people are very friendly 🤗🤗”
    naurahGoogle
  • “Prompt arrival and professional service. Been engaging them for 3 years now. Highly recommend! 👍”
    luckyzackyCarousell
Checks, supported systems and repair guides

The Repair Decision

  • Replace the Handset

    This fits when the installed remote does not transmit correctly and the indoor receiver responds to a known-compatible controller.
  • Replace the Receiver or Display Board

    A model-matched assembly is appropriate when its supply is correct but it cannot detect or pass a valid command.
  • Repair the Indoor Control Path

    A connector, harness, fuse, supply or main-PCB fault needs its own repair instead of another remote.

On-site check $30 / visit, waived if you go ahead with the quoted repair. Rates as of 20 Nov 2026.

Before Replacing the Remote and IR Receiver

  • Batteries or Handset Fault

    A simple remote problem should be proven before any indoor receiver or PCB is quoted.
  • Model or Control Incompatibility

    A universal or replacement remote may transmit codes the installed indoor unit does not understand.
  • Indoor Supply or PCB Fault

    A healthy receiver cannot respond if its board, connector or power supply is unavailable.

What Remote and IR Receiver Work Covers

  • Wireless Remote Handset

    Buttons, batteries, battery contacts, display and infrared output are checked before the indoor unit is opened.
  • Indoor Infrared Receiver

    The receiver may sit on a display or button board connected to the indoor main PCB.
  • Command and Control Path

    Wiring, receiver supply, display-board response and indoor-PCB processing can all stop commands.

Confirm your system

A non-responsive aircon does not automatically need a receiver. The remote and indoor power state are checked first.

Frequently Asked Questions

Can you confirm a remote and IR receiver fault from a photo?
A photo cannot confirm a remote and IR receiver fault on its own. It can identify the equipment and any visible damage, but the remote and IR receiver still needs model matching and circuit testing before it is replaced, because other faults on the same circuit give the same symptom.
Do you carry every remote and IR receiver part?
We do not promise fixed stock of every remote and IR receiver part. We identify the model, the part specification and the assembly first, then confirm the price and the lead time before you approve the work, so the part fitted matches your unit.
Is remote and IR receiver replacement always a major repair?
Remote and IR receiver replacement is not always a major repair. The scope depends on access, whether the part is separate or built into a larger assembly, and whether the connected motor, PCB or system remains serviceable. Testing on site settles which applies.

Ready to Get Started?

Include what’s happening, brand and model (if known) and when it started.

WhatsApp us