Daikin RZF71CV1G

The outdoor unit of a 7.13 kW single split system, rated 4 green ticks. Costs about $72 a month to run — here is how that compares with every other system its size on Singapore's NEA register.

RZF71CV1G running costs

9 of 14 comparable systems have a lower estimated running cost.

Runs at

$72/month

About $859 a year

Cheapest its size

$60/month

Fujitsu AOAH24CBTA

Size group

6.6–7.7 kW

15 systems, all brands

That is about $12 a month more than the lowest estimate, or about $1,420 over ten years at the same tariff and usage.

Its energy efficiency ranks 5 of 15 by weighted COP, a measure of cooling delivered per unit of electricity.

Similar systems that cost less to run

Ordered by closest cooling capacity. The estimates cover electricity. Compare purchase price, indoor units and installation separately.

  • Capacity
    7.02 kW
    Green ticks
    4 ticks
    Runs at
    $67/month
    Monthly savings
    $5/month
  • Capacity
    7.26 kW
    Green ticks
    5 ticks
    Runs at
    $60/month
    Monthly savings
    $12/month
  • Capacity
    6.9 kW
    Green ticks
    5 ticks
    Runs at
    $63/month
    Monthly savings
    $9/month
  • Capacity
    6.73 kW
    Green ticks
    4 ticks
    Runs at
    $64/month
    Monthly savings
    $8/month

What to check in your quote

This is the outdoor half of a pair. The indoor unit is the half you live with, and it should be named before anything is agreed.

  • The paired indoor model number: the unit that mounts in the room
  • Whether the capacity suits that room, and how that was decided
  • What happens to the existing piping, drainage and bracket
  • Whether the old unit is being removed and disposed of

NEA energy-label figures checked 17 Sept 2026. Cost estimates use the label’s 27¢/kWh assumption. Your bill depends on your usage and tariff.

Daikin RZF71CV1G questions

Is the Daikin RZF71CV1G the right size for my room?
The NEA register lists it at 7.13 kW of cooling capacity. Match that against the room's size and heat load rather than assuming one capacity suits every room, and have the installer confirm it before the unit is chosen.
What does the 4-tick rating on the RZF71CV1G mean?
The NEA energy label rates it 4 of 5 green ticks, in the upper band for tested efficiency. Ticks describe energy use under the label test, not cooling strength, so compare it with units of the same size.
Is the RZF71CV1G a single-split or multi-split system?
It is a single-split: one outdoor unit paired with one indoor unit, listed at 7.13 kW on the register. That makes it a one-room system, and the quote should name the paired indoor model.
Is the Daikin RZF71CV1G still on the NEA register?
Yes. Its registration runs to 18 November 2029, more than four months after the 17 September 2026 snapshot this page is built from.
How efficient is the RZF71CV1G at part load?
NEA records a part-load COP of 6.21 for the RZF71CV1G. Part-load efficiency describes how it performs when it is not running flat out, which is how it runs most of the time in a home.