Fujitsu AOAG12CMTA

The outdoor unit of a 3.59 kW single split system, rated 5 green ticks. Costs about $30 a month to run — here is how that compares with every other system its size on Singapore's NEA register.

Is the AOAG12CMTA expensive to run?

No, it's one of the cheaper ones its size. Of the 26 systems on Singapore's register around this size, 2 cost less to run.

Runs at

$30/month

About $358 a year

Cheapest its size

$29/month

GREE GWC12ATDXE-K6DNA3A/O

Size group

3.3–3.9 kW

26 systems, all brands

That is about $1 a month more than the cheapest system its size, or roughly $110 over ten years — before you weigh purchase price, which often runs the other way.

It is not an inefficient unit, though. It sits at the larger end of its size group, so it works harder for the same rating. On efficiency alone it ranks 1 of 26 — middle of the pack.

Looking at the AOAG12CMTA for your home?

This is the outdoor half of a pair. The indoor unit is the half you live with, and it should be named before anything is agreed.

What to pin down before you commit

  • The paired indoor model number — the unit that mounts in the room
  • Whether the capacity suits that room, and how that was decided
  • What happens to the existing piping, drainage and bracket
  • Whether the old unit is being removed and disposed of

Figures are NEA energy-label records checked 17 Sept 2026, priced at the label's 27¢/kWh assumption. Your own bill depends on how you actually use it. Look up a fault code if one is already installed. Compare every registered model, or read more on Fujitsu systems. Common aircon problems have their own pages.

Fujitsu AOAG12CMTA questions

Is the Fujitsu AOAG12CMTA the right size for my room?
The NEA register lists it at 3.59 kW of cooling capacity. Match that against the room's size and heat load rather than assuming one capacity suits every room, and have the installer confirm it before the unit is chosen.
What does the 5-tick rating on the AOAG12CMTA mean?
The NEA energy label rates it 5 of 5 green ticks, in the upper band for tested efficiency. Ticks describe energy use under the label test, not cooling strength, so compare it with units of the same size.
Is the AOAG12CMTA a single-split or multi-split system?
It is a single-split: one outdoor unit paired with one indoor unit, listed at 3.59 kW on the register. That makes it a one-room system, and the quote should name the paired indoor model.
Is the Fujitsu AOAG12CMTA still on the NEA register?
Yes. Its registration runs to 11 July 2028, more than four months after the 17 September 2026 snapshot this page is built from.
How efficient is the AOAG12CMTA at part load?
NEA records a part-load COP of 6.48 for the AOAG12CMTA. Part-load efficiency describes how it performs when it is not running flat out, which is how it runs most of the time in a home.