Skip to main content
snowflakeaircon.sg
WhatsApp

5.0onGoogle&Carousell

15,000+ jobs completed

Mitsubishi Heavy Industries FDC100YNA-W8

The outdoor unit of a 9.64 kW single split system, rated 4 green ticks. Costs about $94 a month to run — here is how that compares with every other system its size on Singapore's NEA register.

Is the FDC100YNA-W8 expensive to run?

A bit, yes. Of the 12 systems on Singapore's register around this size, 6 cost less to run.

Runs at

$94/month

About $1,126 a year

Cheapest its size

$80/month

Daikin RZFV100AVMG

Size group

8.9–10.4 kW

12 systems, all brands

That is about $14 a month more than the cheapest system its size, or roughly $1,630 over ten years — before you weigh purchase price, which often runs the other way.

It is not an inefficient unit, though. It sits at the larger end of its size group, so it works harder for the same rating. On efficiency alone it ranks 6 of 12 — middle of the pack.

Cheaper systems the same size

Closest in size first. Cheaper to run is not the same as the better buy — purchase price, indoor units, and how well it is installed all sit outside these figures.

Looking at the FDC100YNA-W8 for your home?

This is the outdoor half of a pair. The indoor unit is the half you live with, and it should be named before anything is agreed.

What to pin down before you commit

  • The paired indoor model number — the unit that mounts in the room
  • Whether the capacity suits that room, and how that was decided
  • What happens to the existing piping, drainage and bracket
  • Whether the old unit is being removed and disposed of

Figures are NEA energy-label records checked 17 Sept 2026, priced at the label's 27¢/kWh assumption. Your own bill depends on how you actually use it. Compare every registered model, or read more on Mitsubishi Heavy Industries systems. Common aircon problems have their own pages.

Mitsubishi Heavy Industries FDC100YNA-W8 questions

Is the Mitsubishi Heavy Industries FDC100YNA-W8 the right size for my room?
The NEA register lists it at 9.64 kW of cooling capacity. Match that against the room's size and heat load rather than assuming one capacity suits every room, and have the installer confirm it before the unit is chosen.
What does the 4-tick rating on the FDC100YNA-W8 mean?
The NEA energy label rates it 4 of 5 green ticks, in the upper band for tested efficiency. Ticks describe energy use under the label test, not cooling strength, so compare it with units of the same size.
Is the FDC100YNA-W8 a single-split or multi-split system?
It is a single-split: one outdoor unit paired with one indoor unit, listed at 9.64 kW on the register. That makes it a one-room system, and the quote should name the paired indoor model.
Is the Mitsubishi Heavy Industries FDC100YNA-W8 still on the NEA register?
Yes. Its registration runs to 11 March 2028, more than four months after the 17 September 2026 snapshot this page is built from.
How efficient is the FDC100YNA-W8 at part load?
NEA records a part-load COP of 5.75 for the FDC100YNA-W8. Part-load efficiency describes how it performs when it is not running flat out, which is how it runs most of the time in a home.