Mitsubishi Heavy Industries FDC71GNA-W8

The outdoor unit of a 7.22 kW single split system, rated 4 green ticks. Costs about $73 a month to run.

This model is no longer listed on Singapore’s NEA register. The figures below describe its final recorded entry.

Cheaper systems the same size

Closest in size first. Cheaper to run is not the same as the better buy — purchase price, indoor units, and how well it is installed all sit outside these figures.

  • Capacity
    7.26 kW
    Green ticks
    5 ticks
    Runs at
    $60/month
    You would save
    $13/month
  • Capacity
    7.02 kW
    Green ticks
    4 ticks
    Runs at
    $67/month
    You would save
    $7/month
  • Capacity
    6.9 kW
    Green ticks
    5 ticks
    Runs at
    $63/month
    You would save
    $10/month
  • Capacity
    6.73 kW
    Green ticks
    4 ticks
    Runs at
    $64/month
    You would save
    $10/month

Looking at the FDC71GNA-W8 for your home?

This is the outdoor half of a pair. The indoor unit is the half you live with, and it should be named before anything is agreed.

What to pin down before you commit

  • The paired indoor model number — the unit that mounts in the room
  • Whether the capacity suits that room, and how that was decided
  • What happens to the existing piping, drainage and bracket
  • Whether the old unit is being removed and disposed of

Figures are NEA energy-label records checked 17 Sept 2026, priced at the label's 27¢/kWh assumption. Your own bill depends on how you actually use it. Compare every registered model, or read more on Mitsubishi Heavy Industries systems. Common aircon problems have their own pages.

Mitsubishi Heavy Industries FDC71GNA-W8 questions

Is the Mitsubishi Heavy Industries FDC71GNA-W8 the right size for my room?
The NEA register lists it at 7.22 kW of cooling capacity. Match that against the room's size and heat load rather than assuming one capacity suits every room, and have the installer confirm it before the unit is chosen.
What does the 4-tick rating on the FDC71GNA-W8 mean?
The NEA energy label rates it 4 of 5 green ticks, in the upper band for tested efficiency. Ticks describe energy use under the label test, not cooling strength, so compare it with units of the same size.
Is the FDC71GNA-W8 a single-split or multi-split system?
It is a single-split: one outdoor unit paired with one indoor unit, listed at 7.22 kW on the register. That makes it a one-room system, and the quote should name the paired indoor model.
Is the Mitsubishi Heavy Industries FDC71GNA-W8 still on the NEA register?
No. Its registration expired on 27 August 2026, so the figures on this page describe the record as captured on 17 September 2026 rather than current stock.
How efficient is the FDC71GNA-W8 at part load?
NEA records a part-load COP of 5.47 for the FDC71GNA-W8. Part-load efficiency describes how it performs when it is not running flat out, which is how it runs most of the time in a home.