Daikin Aircon E6 Error Code

Daikin E6 means faulty compressor start up on EZi, iSmart ENVi and iSmile and other models. Switch the unit off if E6 shows and leave it off.

What it means
Faulty compressor start up on EZi, iSmart ENVi and iSmile and other models. Other Daikin models list a different meaning for E6; match the model first.
Is it serious?
Yes. Daikin E6 is a high-severity compressor fault. Have it diagnosed before relying on the unit.
Can I keep running it?
Switch the unit off if E6 shows and leave it off. Forcing a compressor or inverter fault to run adds to the damage. Do not power-cycle the unit to clear the display. The manufacturer's fault list gives no homeowner fix for E6, so leave it for diagnosis.
Is it worth repairing?
Whether Daikin E6 is worth repairing depends on the unit's age, the part that has failed, and that repair's cost against a new unit. For this fault type the part is usually in the compressor or its inverter drive. A confirmed compressor failure on an older unit is where a replacement is most often priced beside the repair. The code names the fault, not the failed part, so measure before you decide on E6.Daikin by age, from our Daikin page:
Daikin repair-or-replace guidance by system age
System ageUsual call
Under 5 yearsAlmost always worth repairing.
5–8 yearsRepair is still the default for most faults.
8–12 yearsDepends on the fault.
Over 12 yearsMajor component failures usually favour replacement.
What it costs to find out
An on-site check in Singapore costs $30 and finds what is causing Daikin E6 before any repair is quoted. The fee is waived if you go ahead with the quoted work. Rates as of 20 Nov 2026, on our Pricing page.
On this page

What Does Daikin E6 Mean?

Daikin E6 means faulty compressor start up on EZi, iSmart ENVi and iSmile and other models. Other Daikin models list a different meaning for E6; match the model first.

What Causes Daikin E6?

Daikin Simple Self-Diagnosis by Malfunction Code (SM-TS3) lists 3 causes for Daikin E6.

  • Defective compressor.

  • Defective control PCB.

  • Stop valve is not opened.

Which Daikin E6 Meaning Matches Your Unit?

Daikin E6 has more than one listed meaning. Your model, the system type and the unit that shows the code decide which one applies.

  • Model / series
    EZi
    What it means
    Faulty compressor start up
  • Model / series
    General RA self-diagnosis guide
    What it means
    STD compressor motor overcurrent or lock

What Does a Technician Check for Daikin E6?

Before quoting parts for Daikin E6, a technician should confirm whether E6 is compressor start, overload, lock, or drive protection.

  • Check supply voltage, inverter output, IPM status, compressor current, and winding readings.

  • Review trip history and compressor mechanical signs before quoting replacement.

  • Detail
    Diagnostic note
    What it says
    Stop the system if it smells burnt, leaks, or trips power; note the exact model and code before booking diagnosis.

Will Daikin E6 Need a Repair or a New Unit?

Daikin E6 is still a repair if power, inverter or module checks find the cause. Weigh compressor replacement against age, warranty and the rest of the system.

Daikin E6 Questions

What does the Daikin E6 error code mean?
Daikin E6 means faulty compressor start up on EZi, iSmart ENVi and iSmile and other models, according to Daikin CTKC25/35WVMG operation manual. Other Daikin models list a different meaning for E6; match the model first. The code names the fault the unit has detected, not the failed part.
Is it safe to keep running an aircon showing Daikin E6?
Treat Daikin E6 as a fault to diagnose, not a display to clear. Switch the unit off if E6 shows and leave it off. Forcing a compressor or inverter fault to run adds to the damage. Do not power-cycle the unit to clear the display.
What causes Daikin E6?
Daikin Simple Self-Diagnosis by Malfunction Code (SM-TS3) lists these causes for Daikin E6: defective compressor; defective control PCB; stop valve is not opened. A technician tests each one on your unit before replacing any part. The code alone does not say which of them has failed.
Is Daikin E6 worth repairing?
Whether Daikin E6 is worth repairing depends on the unit's age, the part that has failed, and that repair's cost against a new unit. For this fault type the part is usually in the compressor or its inverter drive. A confirmed compressor failure on an older unit is where a replacement is most often priced beside the repair.
How much does it cost to find out what is causing Daikin E6 in Singapore?
An on-site check in Singapore costs $30 and finds what is causing Daikin E6 before any repair is quoted. The fee is waived if you go ahead with the quoted work. Rates as of 20 Nov 2026, on our Pricing page.