Gree Aircon 55 / 56 / 57 / 58 Error Code

Gree 55 / 56 / 57 / 58 means unit A communication wire misconnection or expansion valve malfunction on Multi GEN2 wall mount, Multi GEN2 cassette and Multi GEN2 slim duct and other models. If 55 / 56 / 57 / 58 stays on or returns, do not reset it.

What it means
Unit A communication wire misconnection or expansion valve malfunction on Multi GEN2 wall mount, Multi GEN2 cassette and Multi GEN2 slim duct and other models. Each Gree code in this group identifies Unit A, B, C or D; match the displayed code to the affected unit.
Is it serious?
Yes. Gree 55 / 56 / 57 / 58 is a high-severity communication fault. Have it diagnosed before relying on the unit.
Can I keep running it?
If 55 / 56 / 57 / 58 stays on or returns, do not reset it. The manufacturer lists no reset; arrange diagnosis. The manufacturer's fault list gives no homeowner fix for 55 / 56 / 57 / 58, so leave it for diagnosis.
Is it worth repairing?
Whether Gree 55 / 56 / 57 / 58 is worth repairing depends on the unit's age, the part that has failed, and that repair's cost against a new unit. For this fault type the part is usually in the signal link between the units. A loose terminal or damaged signal wire is a targeted repair; a failed board is replaced, not repaired. The code names the fault, not the failed part, so measure before you decide on 55 / 56 / 57 / 58.Gree by age, from our Gree page:
Gree repair-or-replace guidance by system age
System ageUsual call
Under 5 yearsRepair.
5-8 yearsRepair sensor, fan and minor electrical faults.
Over 8 yearsA compressor or inverter fault on a budget-tier system can reach replacement cost.
What it costs to find out
An on-site check in Singapore costs $30 and finds what is causing Gree 55 / 56 / 57 / 58 before any repair is quoted. The fee is waived if you go ahead with the quoted work. Rates as of 27 Nov 2026, on our Pricing page.

What Does Gree 55 / 56 / 57 / 58 Mean?

Gree 55 / 56 / 57 / 58 means unit A communication wire misconnection or expansion valve malfunction on Multi GEN2 wall mount, Multi GEN2 cassette and Multi GEN2 slim duct and other models. Each Gree code in this group identifies Unit A, B, C or D; match the displayed code to the affected unit.

What Causes Gree 55 / 56 / 57 / 58?

Gree's fault list for Multi GEN2 wall mount gives the meaning of Gree 55 / 56 / 57 / 58 but not its causes. These are typical for this fault type, not listed for 55 / 56 / 57 / 58.

  • Loose, corroded, crossed, or damaged indoor-outdoor signal wiring.

  • Terminal block, connector, or junction fault on the indoor or outdoor side.

  • Indoor or outdoor PCB communication circuit fault after wiring is proven sound.

Which Gree 55 / 56 / 57 / 58 Meaning Matches Your Unit?

Gree 55 / 56 / 57 / 58 has more than one listed meaning. Your model, the system type and the unit that shows the code decide which one applies.

  • Model / series
    55
    What it means
    Unit A communication wire misconnection or expansion valve malfunction
  • Model / series
    56
    What it means
    Unit B communication wire misconnection or expansion valve malfunction
  • Model / series
    57
    What it means
    Unit C communication wire misconnection or expansion valve malfunction
Show 1 more meaning
  • Model / series
    58
    What it means
    Unit D communication wire misconnection or expansion valve malfunction

What Does a Technician Check for Gree 55 / 56 / 57 / 58?

Before quoting parts for Gree 55 / 56 / 57 / 58, a technician should match 55 / 56 / 57 / 58 against your model's meaning before parts are quoted.

  • Test communication terminals, cable continuity, polarity, and outdoor power.

  • Read indoor and outdoor PCB indicators only after the signal path is proven sound.

  • Detail
    Diagnostic note
    What it says
    Check communication wire assignment and expansion valve operation for Unit A.

Will Gree 55 / 56 / 57 / 58 Need a Repair or a New Unit?

Gree 55 / 56 / 57 / 58 starts with terminal, signal-cable and power checks. A board is replaced only after the communication path proves sound.

Gree 55 / 56 / 57 / 58 Questions

What does the Gree 55 / 56 / 57 / 58 error code mean?
Gree 55 / 56 / 57 / 58 means unit A communication wire misconnection or expansion valve malfunction on Multi GEN2 wall mount, Multi GEN2 cassette and Multi GEN2 slim duct and other models, according to Gree's fault list for Multi GEN2 wall mount.
Is it safe to keep running an aircon showing Gree 55 / 56 / 57 / 58?
Treat Gree 55 / 56 / 57 / 58 as a fault to diagnose, not a display to clear. If 55 / 56 / 57 / 58 stays on or returns, do not reset it. The manufacturer lists no reset; arrange diagnosis. Note the 55 / 56 / 57 / 58 display and when it appeared.
What causes Gree 55 / 56 / 57 / 58?
Gree's fault list for Multi GEN2 wall mount gives the meaning of Gree 55 / 56 / 57 / 58 but not its causes. Typical causes for this fault type are loose, corroded, crossed, or damaged indoor-outdoor signal wiring; terminal block, connector, or junction fault on the indoor or outdoor side.
Is Gree 55 / 56 / 57 / 58 worth repairing?
Whether Gree 55 / 56 / 57 / 58 is worth repairing depends on the unit's age, the part that has failed, and that repair's cost against a new unit. For this fault type the part is usually in the signal link between the units. A loose terminal or damaged signal wire is a targeted repair; a failed board is replaced, not repaired.
How much does it cost to find out what is causing Gree 55 / 56 / 57 / 58 in Singapore?
An on-site check in Singapore costs $30 and finds what is causing Gree 55 / 56 / 57 / 58 before any repair is quoted. The fee is waived if you go ahead with the quoted work. Rates as of 27 Nov 2026, on our Pricing page.

Need Help with Your Gree Aircon?

Message us 55 / 56 / 57 / 58 and what your Gree unit is doing. A photo or short video helps us narrow down the cause before any visit.

WhatsApp about 55 / 56 / 57 / 58