LG Aircon CH27 Error Code & Blinking Light
LG CH27 means PSC fault; inverter compressor converter current too high on HSV4 / HSV5 single-zone wall-mounted systems. Switch the unit off if CH27 shows and leave it off.
- What it means
- PSC fault; inverter compressor converter current too high on HSV4 / HSV5 single-zone wall-mounted systems. Other LG models list a different meaning for CH27; match the model first.
- Is it serious?
- Yes. LG CH27 is a high-severity compressor fault. Have it diagnosed before relying on the unit.
- Can I keep running it?
- Switch the unit off if CH27 shows and leave it off. Forcing a compressor or inverter fault to run adds to the damage. Do not power-cycle the unit to clear the pattern. The manufacturer's fault list gives no homeowner fix for CH27, so leave it for diagnosis.
- Is it worth repairing?
- Whether LG CH27 is worth repairing depends on the unit's age, the part that has failed, and that repair's cost against a new unit. For this fault type the part is usually in the compressor or its inverter drive. A confirmed compressor failure on an older unit is where a replacement is most often priced beside the repair. The code names the fault, not the failed part, so measure before you decide on CH27.LG by age, from our LG page:
LG repair-or-replace guidance by system age System age Usual call Under 5 years Repair. 5-8 years Repair. 8-10 years This is the decision point. Over 10 years Replace after a major component failure. - What it costs to find out
- An on-site check in Singapore costs $30 and finds what is causing LG CH27 before any repair is quoted. The fee is waived if you go ahead with the quoted work. Rates as of 20 Nov 2026, on our Pricing page.
What Does LG CH27 Mean?
LG CH27 means PSC fault; inverter compressor converter current too high on HSV4 / HSV5 single-zone wall-mounted systems. Other LG models list a different meaning for CH27; match the model first.
What Causes LG CH27?
LG's fault list for HSV4 / HSV5 single-zone wall-mounted systems gives the meaning of LG CH27 but not its causes. These are typical for this fault type, not listed for CH27.
Compressor start, lock, overcurrent, overload, or inverter-drive protection.
Power-module, IPM, voltage, or wiring fault affecting compressor drive.
Compressor mechanical or winding issue after electrical checks are confirmed.
Which LG CH27 Meaning Matches Your Unit?
LG CH27 has more than one listed meaning. Your model, the system type and the unit that shows the code decide which one applies.
| Model / series | What it means |
|---|---|
| HSV4 / HSV5 single-zone wall-mounted systems | PSC fault; inverter compressor converter current too high |
| LS091HSV / LS121HSV wall-mounted single-zone | Prospective short circuit fault; inverter-compressor current too high between AC and DC converter circuit |
- Model / series
- HSV4 / HSV5 single-zone wall-mounted systems
- What it means
- PSC fault; inverter compressor converter current too high
- Model / series
- LS091HSV / LS121HSV wall-mounted single-zone
- What it means
- Prospective short circuit fault; inverter-compressor current too high between AC and DC converter circuit
What Does a Technician Check for LG CH27?
Before quoting parts for LG CH27, a technician should confirm whether CH27 is compressor start, overload, lock, or drive protection.
Check supply voltage, inverter output, IPM status, compressor current, and winding readings.
Review trip history and compressor mechanical signs before quoting replacement.
| Detail | What it says |
|---|---|
| Diagnostic note | Arrange outdoor inverter, reactor, and compressor electrical diagnosis; avoid repeated resets. |
- Detail
- Diagnostic note
- What it says
- Arrange outdoor inverter, reactor, and compressor electrical diagnosis; avoid repeated resets.
Will LG CH27 Need a Repair or a New Unit?
LG CH27 is still a repair if power, inverter or module checks find the cause. Weigh compressor replacement against age, warranty and the rest of the system.