LG Aircon CH67 Error Code & Blinking Light
LG CH67 means outdoor fan error on inverter split units. If CH67 stays on or returns, do not reset it.
- What it means
- Outdoor fan error on inverter split units. Other LG models list a different meaning for CH67; match the model first.
- Is it serious?
- Yes. LG CH67 is a high-severity fan motor fault. Have it diagnosed before relying on the unit.
- Can I keep running it?
- If CH67 stays on or returns, do not reset it. The manufacturer lists no reset; arrange diagnosis. The manufacturer's fault list gives no homeowner fix for CH67, so leave it for diagnosis.
- Is it worth repairing?
- Whether LG CH67 is worth repairing depends on the unit's age, the part that has failed, and that repair's cost against a new unit. For this fault type the part is usually in a fan motor circuit. The motor, its capacitor or the board driving it each cost differently, so the measured part decides it. The code names the fault, not the failed part, so measure before you decide on CH67.LG by age, from our LG page:
LG repair-or-replace guidance by system age System age Usual call Under 5 years Repair. 5-8 years Repair. 8-10 years This is the decision point. Over 10 years Replace after a major component failure. - What it costs to find out
- An on-site check in Singapore costs $30 and finds what is causing LG CH67 before any repair is quoted. The fee is waived if you go ahead with the quoted work. Rates as of 20 Nov 2026, on our Pricing page. On a LG VRF system, we service but do not repair, so that fault goes to LG's authorised agent.
What Does LG CH67 Mean?
LG CH67 means outdoor fan error on inverter split units. Other LG models list a different meaning for CH67; match the model first.
What Causes LG CH67?
LG's fault list for Inverter Split gives the meaning of LG CH67 but not its causes. These are typical for this fault type, not listed for CH67.
Fan motor locked, slow, not rotating, or outside the expected feedback range.
Fan blade obstruction, worn motor, weak capacitor, or damaged motor harness.
Indoor or outdoor PCB drive fault after the motor and wiring are tested.
Which LG CH67 Meaning Matches Your Unit?
LG CH67 has more than one listed meaning. Your model, the system type and the unit that shows the code decide which one applies.
| Model / series | What it means |
|---|---|
| Inverter Split | Outdoor fan error. |
| LS091HSV / LS121HSV wall-mounted single-zone | Outdoor BLDC fan motor lock error |
| LG Multi V 5 commercial VRF: master outdoor unit: Outdoor-unit fan lock | master outdoor unit: Outdoor-unit fan lock |
- Model / series
- Inverter Split
- What it means
- Outdoor fan error.
- Model / series
- LS091HSV / LS121HSV wall-mounted single-zone
- What it means
- Outdoor BLDC fan motor lock error
- Model / series
- LG Multi V 5 commercial VRF: master outdoor unit: Outdoor-unit fan lock
- What it means
- master outdoor unit: Outdoor-unit fan lock
Show 2 more meanings
| Model / series | What it means |
|---|---|
| LG Multi V 5 commercial VRF: slave 1 outdoor unit: Outdoor-unit fan lock | slave 1 outdoor unit: Outdoor-unit fan lock |
| LG Multi V 5 commercial VRF: slave 2 outdoor unit: Outdoor-unit fan lock | slave 2 outdoor unit: Outdoor-unit fan lock |
- Model / series
- LG Multi V 5 commercial VRF: slave 1 outdoor unit: Outdoor-unit fan lock
- What it means
- slave 1 outdoor unit: Outdoor-unit fan lock
- Model / series
- LG Multi V 5 commercial VRF: slave 2 outdoor unit: Outdoor-unit fan lock
- What it means
- slave 2 outdoor unit: Outdoor-unit fan lock
What Does a Technician Check for LG CH67?
Before quoting parts for LG CH67, a technician should confirm whether CH67 points to the indoor fan, outdoor fan, or drive circuit.
Check for blade obstruction, motor winding, feedback signal, and connector condition.
Confirm PCB fan-drive output before quoting a motor or board.
| Detail | What it says |
|---|---|
| Diagnostic note | Outdoor fan error. Check for visible debris or obstruction around the outdoor fan, then request service if the code returns. |
- Detail
- Diagnostic note
- What it says
- Outdoor fan error. Check for visible debris or obstruction around the outdoor fan, then request service if the code returns.
Will LG CH67 Need a Repair or a New Unit?
LG CH67 is a repair once the motor, blade or feedback circuit is confirmed. System replacement only comes up when the motor or board cost is poor value for the system's age.