Midea Aircon PC 42 Error Code
Midea PC 42 means compressor start error. Switch the unit off if PC 42 shows and leave it off.
- What it means
- Compressor start error.
- Is it serious?
- Yes. Midea PC 42 is a high-severity compressor fault. Have it diagnosed before relying on the unit.
- Can I keep running it?
- Switch the unit off if PC 42 shows and leave it off. Forcing a compressor or inverter fault to run adds to the damage. Do not power-cycle the unit to clear the display. The manufacturer's fault list gives no homeowner fix for PC 42, so leave it for diagnosis.
- Is it worth repairing?
- Whether Midea PC 42 is worth repairing depends on the unit's age, the part that has failed, and that repair's cost against a new unit. For this fault type the part is usually in the compressor or its inverter drive. A confirmed compressor failure on an older unit is where a replacement is most often priced beside the repair. The code names the fault, not the failed part, so measure before you decide on PC 42.Midea by age, from our Midea page:
Midea repair-or-replace guidance by system age System age Usual call Under 3 years Repair, and check the warranty first. 3-5 years Repair sensor, drainage and capacitor faults. 5-7 years This is the decision range. Over 7 years Replace after a major component failure. - What it costs to find out
- An on-site check in Singapore costs $30 and finds what is causing Midea PC 42 before any repair is quoted. The fee is waived if you go ahead with the quoted work. Rates as of 20 Nov 2026, on our Pricing page.
What Does Midea PC 42 Mean?
Midea PC 42 is listed as compressor start error in Wall-Mounted Split, Standard Non-Inverter entries such as Midea Xtreme ONOFF R32 MSAGB wall-mounted fixed-speed systems. This meaning comes from the manufacturer's own diagnostic material. Confirm the exact model and series before accepting a parts quote.
What Causes Midea PC 42?
Midea's fault list for Midea Xtreme ONOFF R32 MSAGB wall-mounted fixed-speed systems gives the meaning of Midea PC 42 but not its causes. These are typical for this fault type, not listed for PC 42.
Compressor start, lock, overcurrent, overload, or inverter-drive protection.
Power-module, IPM, voltage, or wiring fault affecting compressor drive.
Compressor mechanical or winding issue after electrical checks are confirmed.
What Does a Technician Check for Midea PC 42?
Before quoting parts for Midea PC 42, a technician should confirm whether PC 42 is compressor start, overload, lock, or drive protection.
Check supply voltage, inverter output, IPM status, compressor current, and winding readings.
Review trip history and compressor mechanical signs before quoting replacement.
| Detail | What it says |
|---|---|
| Diagnostic note | Use the source quick-check path: Check compressor terminals, capacitor, outdoor PCB output, and locked-compressor signs. |
| Singapore / model note | Official Midea Xtreme ONOFF wall-mounted service-manual entry. Keep separate from the newer inverter and compact Forest ONOFF entries because the source lists this fixed-speed family by EH / EL / EC / PC / PH display codes. |
- Detail
- Diagnostic note
- What it says
- Use the source quick-check path: Check compressor terminals, capacitor, outdoor PCB output, and locked-compressor signs.
- Detail
- Singapore / model note
- What it says
- Official Midea Xtreme ONOFF wall-mounted service-manual entry. Keep separate from the newer inverter and compact Forest ONOFF entries because the source lists this fixed-speed family by EH / EL / EC / PC / PH display codes.
Will Midea PC 42 Need a Repair or a New Unit?
Midea PC 42 is still a repair if power, inverter or module checks find the cause. Weigh compressor replacement against age, warranty and the rest of the system.