What does Mitsubishi Electric 06 / LED1 lit, LED2 7x mean?
Mitsubishi Electric 06 / LED1 lit, LED2 7x is listed as nonvolatile memory data in Multi-Split rows such as FP Series, Starmex R32. This meaning comes from the manufacturer's own diagnostic material. Confirm the exact model, series, or signal row before accepting a parts quote.
Indoor or outdoor PCB fault, as the manufacturer lists it.
Power supply, connector, fuse, EEPROM, or board-input problem.
Water ingress, surge damage, or wiring issue that must be ruled out before board replacement.
What to do now
Use these steps before customer action or a parts quote.
Stop using the unit if 06 / LED1 lit, LED2 7x returns
If 06 / LED1 lit, LED2 7x remains displayed or returns during operation, do not attempt a reset the manufacturer does not list; arrange diagnosis.
No manufacturer reset steps listed for 06 / LED1 lit, LED2 7x
Capture the complete 06 / LED1 lit, LED2 7x pattern and model stickers first. The manufacturer lists no customer reset procedure; do not treat a generic power-cycle as manufacturer guidance.
Send these to us
06 / LED1 lit, LED2 7x blinking light, a short video of the blinking-light sequence, Mitsubishi Electric model stickers, affected rooms, and operating state when the code appeared
Guidance for your model
Notes that match the code to your exact model. Electrical, refrigerant, wiring, resistance and component checks are for a technician.
| Detail | What it says |
|---|---|
| Diagnostic note | Do not keep resetting the system if this pattern returns. Record the model number, lamp or LED pattern, and affected rooms before booking diagnosis. |
| Singapore / model note | Official Mitsubishi Electric checklist action: Replace inverter P.C. board. |
- Detail
- Diagnostic note
- What it says
- Do not keep resetting the system if this pattern returns. Record the model number, lamp or LED pattern, and affected rooms before booking diagnosis.
- Detail
- Singapore / model note
- What it says
- Official Mitsubishi Electric checklist action: Replace inverter P.C. board.
What to check before repair
Use this split to separate safe evidence capture from the tests a technician should prove before quoting parts.
| You can check | Technician should confirm |
|---|---|
| Before taking any system action on 06 / LED1 lit, LED2 7x, take a short video of the blinking-light sequence. | Confirm which PCB or board input 06 / LED1 lit, LED2 7x points to for your model. |
| Capture the Mitsubishi Electric indoor and outdoor model stickers so the correct family row is used. | Check power supply, fuses, connectors, wiring, and board indicators. |
| The manufacturer lists no customer reset procedure for this code. Note whether one room, several rooms, or the whole system is affected. | Rule out water ingress, surge damage, and connected component faults before replacing the board. |
- You can check
- Before taking any system action on 06 / LED1 lit, LED2 7x, take a short video of the blinking-light sequence.
- Technician should confirm
- Confirm which PCB or board input 06 / LED1 lit, LED2 7x points to for your model.
- You can check
- Capture the Mitsubishi Electric indoor and outdoor model stickers so the correct family row is used.
- Technician should confirm
- Check power supply, fuses, connectors, wiring, and board indicators.
- You can check
- The manufacturer lists no customer reset procedure for this code. Note whether one room, several rooms, or the whole system is affected.
- Technician should confirm
- Rule out water ingress, surge damage, and connected component faults before replacing the board.
What changes the next step
These clues decide whether the first check is room-side, shared outdoor-side, refrigerant-side, listed-meaning, or model-family confirmation.
| What you see | What it points to |
|---|---|
| Only one indoor unit shows 06 / LED1 lit, LED2 7x. | The affected room, indoor board path, wiring route, or local component should be checked first. |
| Several rooms or the outdoor unit show the same 06 / LED1 lit, LED2 7x fault. | Prioritise the shared outdoor side, power path, and source-listed system branch. |
| The fault remains displayed or returns during operation. | Start with the checks the manufacturer lists for this code before approving parts. |
| The model family is different from the row you found online. | Use the model or series filter first; same-looking codes can still belong to different diagnostic tables. |
| The model belongs to Multi-Split rows such as FP Series, Starmex R32. | This meaning comes from the manufacturer's own diagnostic material. Match the code to your model's listing before parts are quoted. |
- What you see
- Only one indoor unit shows 06 / LED1 lit, LED2 7x.
- What it points to
- The affected room, indoor board path, wiring route, or local component should be checked first.
- What you see
- Several rooms or the outdoor unit show the same 06 / LED1 lit, LED2 7x fault.
- What it points to
- Prioritise the shared outdoor side, power path, and source-listed system branch.
- What you see
- The fault remains displayed or returns during operation.
- What it points to
- Start with the checks the manufacturer lists for this code before approving parts.
- What you see
- The model family is different from the row you found online.
- What it points to
- Use the model or series filter first; same-looking codes can still belong to different diagnostic tables.
- What you see
- The model belongs to Multi-Split rows such as FP Series, Starmex R32.
- What it points to
- This meaning comes from the manufacturer's own diagnostic material. Match the code to your model's listing before parts are quoted.
PCB repair or replacement decision
Mitsubishi Electric 06 / LED1 lit, LED2 7x should not jump straight to board replacement. Confirm power, connectors, wiring, and connected parts before deciding whether PCB repair or replacement is justified.
Power, fuse, connector, and water-ingress checks should happen before board replacement.
Connected motors, sensors, or valves can damage or confuse a PCB diagnosis.
Board availability and system age decide whether replacement is sensible.
Mitsubishi Electric 06 / LED1 lit, LED2 7x questions
What does the Mitsubishi Electric 06 / LED1 lit, LED2 7x error mean?
Can I fix a Mitsubishi Electric 06 / LED1 lit, LED2 7x error myself?
Is it safe to keep running the aircon with a 06 / LED1 lit, LED2 7x error?
What causes a Mitsubishi Electric 06 / LED1 lit, LED2 7x error?
Will a Mitsubishi Electric 06 / LED1 lit, LED2 7x error need a repair or a full replacement?
What should I send a technician about a Mitsubishi Electric 06 / LED1 lit, LED2 7x error?
Where to go next
Confirm the fault
Share the error code, model number and symptoms so we can assess the likely cause.
Not the right code?
Browse the full Mitsubishi Electric list or check a few codes in the same fault category.
Read next
Use these if the quote mentions the parts, checks, or repair path this code points to.