Mitsubishi Electric Aircon PCB Repair in Singapore
A Mitsubishi Electric that has power but will not start, keeps restarting or shows a communication code may need a new board, or only a smaller fix to its wiring or controls. We test the supply, wiring, sensors and connected parts before quoting a replacement board.
On-site check: $30 / visit. Visit fee waived if you proceed with the quoted work.
Signs Your Mitsubishi Electric Aircon Needs a PCB Check
The Unit Has Power but Will Not Start
Lights or the controller may still respond while the indoor unit, outdoor unit or both refuse to run normally.One Room or the Whole System Stops Responding
The pattern across rooms helps separate an indoor-board problem from an outdoor or shared communication fault.A Communication or Board-Related Error Appears
Service Scope
Find the cause
We check power, wiring and sensors to isolate the fault. Depending on the model, we test the indoor and outdoor boards or inverter drive.
Confirm the repair and quote
We quote the repair and confirm parts and lead time before you approve. If the board has failed, we replace it with one of the same revision and test startup, controls and communication after fitting.
Workmanship Warranty
Labour
30-day workmanship warranty. If the same fault returns from our repair, we come back and the labour is on us, with no second on-site check fee.
Parts
Parts carry the distributor's warranty for that component, so the term varies by part. We tell you both terms before you approve the work.
Photos from Recent Jobs
What Customers Say
“Great people and process. Booked their $30 check when my air conditioner could not switch on. They traced the problem to wiring. No upsell, no drama. Repair done same day, check fee waived. Everything upfront, no hidden cost. Definitely would use their services again! 5/5”
Yong Jun YeoGoogle “The installer for my new aircon had done a brillant job and the communication had been seamless as well. I am happy in engaging their service!😄”
cz0903Carousell “Repeated the chemical wash today. Their professional team made sure there was minimal mess and dirt during the process. Can really feel the difference, the aircon feels much better after the servicing. Very satisfied with their service!”
jonathan limGoogle “they are amazingly on time, and very upfront on the prices. Friendly disposition and they provided valuable advices. i like how that they only sell what you need. Just awesome!”
makchique_specsCarousell “Customer service was prompt and responsive throughout. Guys came on time, helped to advise on the proper cleaning and relocation, even helped me to save money. Highly recommended!”
A NGoogle “The guys at Snowflake go above & beyond in terms of customer service. I had contacted them due to my aircon unit leaking. The guys spent an hour doing chemical clean. However my unit starting leaking again that night. Snowflake were extremely proactive by sending same guys next guy to fix the problem. They located pipe outside & cleared it. Really highly recommend 👍🏼🤩”
nazzasgCarousell “For our 1 year contract, we are satisfied with the efficiency and skilled of the technicians who maintained our aircon. Easy to schedule and coordinate. Hence, we will re contract for another year. Thanks for your service.”
Marian ArcaoGoogle “Fast and efficient service! 100% satisfied with the fast work! Arrived on time and work done was very professional for our commercial unit! Even provide us with new controller (at a price) cause ours didnt work anymore! 😔”
baecaresgCarousell “Used them a few times, very pleased with service level and prices. They provide honest advice on what is needed or not. Plus, they always bring a tarp to cover surfaces. No dodgy upselling practices. Recommended. Will continue to engage their service.”
HW LGoogle “Angeline is very patient in answering all my queries via chat. Tony came to check and does the necessary and give really good recommendation and advices on what is really needed to be done. Recommended 👍”
lill.yCarousell “Excellent Experience Installing System 3 Air Conditioner Knowledgeable, flexible, and efficient service.”
David NgGoogle “Excellent service, able to solve our problem with the aircon removal professionally and goes the extra mile to help us! Would recommend 101%! 💯💯”
kullookCarousell “Mr Yi Tat & Mr Kian were very efficient at servicing 4 ACs within 2 hours! They were very friendly and extremely easy to communicate with throughout the process. Will definitely call them back for future servicing. Thank you, gentlemen!”
Murshidah MunibGoogle “Engaged them because of good reviews and truly they deserved the good reviews. Tony and Ian were able to rectify my problems (other technician was not able to pin point the fault). Repaired and service with resonable charges. Thanks Tony and Ian for solving my issue. 🙏”
ngeokhimCarousell “My go to Aircon servicing for years on. Always prompt in responses and punctual on day if servicing. If delays are expected, they will update via WhatsApp. Never upsell and is honest and dependable. I always have Yen for my servicing. great guy!”
Joanne CGoogle “Technician came within the time frame that they provided and the technician even go extra miles in cleaning and wiping the surrounding areas after chemical wash. Servicing is indeed good”
SharonnczyCarousell “The technician explained their solution thoroughly and their price is transparent. Recommended”
Zi Hao TanGoogle “trusted,easy&fast reply..e service was excellent..e servicing man advice abt my aircon..no messy dust..👍 now my 3 unit aircon getting much colder...tqsm..(will deal wif u again)❤”
idaomrsleeCarousell “Great service! The response was very fast and they arranged the repair quickly. The technician was experienced and knew exactly what to do. Everything was fixed efficiently and the pricing was very reasonable. Definitely value for money—highly recommended!”
Alex LuGoogle “Thumbs up for snowflake aircon service. Delayed a bit on the arrival but they are able to inform prehand. Their guys are very professional to recommend what's the best solution for me. Reasonable price with quality work. Will surely engage them again :)”
ivanaviCarousell “My family has been going back to them for 10 years+. Service is always amazing and the people are very friendly 🤗🤗”
naurahGoogle “Prompt arrival and professional service. Been engaging them for 3 years now. Highly recommend! 👍”
luckyzackyCarousell
Checks, models and error codes
Is Mitsubishi Electric PCB Repair Worth It?
Replacing the PCB is usually sensible when the rest of the system is healthy, the exact board revision is available and testing has ruled out wiring, sensors and connected loads.
| System age | Usual call |
|---|---|
| Starmex under 5 years | Repair. |
| Starmex 5–8 years | Repair is still cost-effective. |
| Starmex 8–12 years | PCB and inverter board failures become more frequent. |
| Starmex over 12 years | Parts are harder to source. |
Reasons for each row: full Mitsubishi Electric table.
You can wait
Testing finds a loose connector or a bad sensor. Fix that and keep the board.
Do not wait
The compressor fails to start on most attempts. A failing board does not recover, and an intermittent fault becomes permanent.
On-site check $30 / visit, waived if you go ahead with the quoted repair. Rates as of 20 Nov 2026. See our aircon system replacement process.
A Board-Related Code Does Not Always Mean a Failed PCB
Power or Wiring Fault
Loose terminals, a damaged interconnect or unstable supply can produce board and communication errors.Sensor or Connected Load
A shorted thermistor, motor or valve can pull down a healthy board or make its input look incorrect.Inverter Power Stage
On inverter systems, the main control PCB and the IPM or driver circuit are tested as separate failure points.
What Is Different on Mitsubishi Electric Systems
Mitsubishi Electric uses both display codes and lamp patterns across its families. We match the observed display to the model before deciding whether the fault sits indoors, outdoors or in communication wiring.
Examples of Mitsubishi Electric Systems We Check
Starmex R32 Single-Split Systems
Starmex R32 Multi-Split and MSXY-FN Indoor Units
PLY Cassette, PEY Ducted and City Multi Systems, with Scope Confirmed from the Exact Family
Model not listed
Message us the error code or what the unit is doing. A photo or short video helps if you have one.
Parts and timing
Starmex parts for current and recent residential families are generally available. Older commercial or discontinued boards require an exact model and part-number check.
Mitsubishi Electric Error Codes Related to PCB Problems
Choose where the code appeared on your unit.
Indoor unit or controller20 guides
- 0095Warning that a metering device may be damaged
- 0100Connected equipment abnormality
- 6601M-NET communication polarity has not been established
- 6602M-NET transmission-processor hardware error
- 6603M-NET transmission line is busy; M-NET transmission bus busy
- 6604No M-NET ACK (06H) because of a communication-circuit error
- 6605No M-NET response frame was received
- 6606M-NET transmission-processor communication error; Communication error with the M-NET transmission processor
- 6607No M-NET acknowledgement was returned; M-NET no-acknowledgement communication error
- 6608No M-NET response frame was returned; M-NET no-response communication error
- 6920Controller communication no-response error
- 6922Controller communication received-frame ID error
- E0Remote-controller receiving error; Remote controller transmission error
- E1Remote-controller control-board memory error; Remote controller control board error
- E2Remote-controller clock-function error
- E3Remote-controller transmitting error
- E4Indoor controller cannot receive the remote-controller signal; Remote-controller signal receiving error
- E5Indoor controller cannot transmit on the remote-controller path; Remote-controller signal transmitting error
- E6 / E7Indoor-outdoor communication receiving error; Indoor-outdoor communication transmitting error
- FB / FbIndoor controller memory or control-system error; Indoor control-system or memory error
Outdoor unit3 guides
Whole-system faults15 guides
- 6201PZ-62DR remote-controller circuit-board failure
- 6202PZ-62DR remote-controller clock or circuit-board failure
- 6801PZ-43SMF-E remote-controller communication error
- 6831PZ-62DR remote-controller no-reception communication error; Signal reception fault at the MA controller with no signal received
- 6832PZ-62DR remote-controller synchronization-recovery communication error; Signal transmission synchronization fault at the MA controller
- 6833PZ-62DR remote-controller communication hardware error; Signal transmission hardware fault at the MA controller
- 6834PZ-62DR start-bit detection or leader-follower communication error; Signal reception start-bit detection fault at the MA controller
- E8Indoor/outdoor communication receiving error; Serial signal
- E9Indoor/outdoor communication receiving error; Indoor-outdoor unit communication error
- ECIndoor/outdoor communication receiving error
- U6Compressor overcurrent or power-module abnormality
- U8Outdoor fan protection stop
- U9 / UHPower-voltage, synchronous-signal, or current-sensor abnormality
- UFCompressor locked or overcurrent interruption
- UPCompressor overcurrent interruption
Codes that depend on the exact model22 guides
- 04 / LED 6xSerial signal
- 06 / LED1 lit, LED2 6xZero cross detecting circuit on outdoor control P.C. board
- 06 / LED1 lit, LED2 7xNonvolatile memory data
- 09 / LED1 lit, LED2 11xCommunication error between P.C. boards
- 10 / LED1 lit, LED2 12xZero cross detecting circuit on outdoor power P.C. board
- 13 / LED1 lit, LED2 15xRelay operation
- 24 / LED1 lit, LED2 11xCommunication between P.C. boards protection
- 25 / LED1 lit, LED2 12xZero cross detecting circuit on outdoor power P.C. board
- 0403Serial or panel communication fault involving the indoor or auto-filter-cleaning control boards; Serial communication fault between the outdoor control board and the inverter or fan board
- 4225Control power-supply fault
- 4226Low bus voltage at startup
- 5305Fan-board current-sensor fault
- 5306Fan-board current-sensor circuit fault
- 7110Connection-information signal transmission or reception fault
- EdSerial communication error between outdoor boards or M-NET communication error
- EFCheck code is not defined
- FR03 / recall upper lamp 3xSerial signal from outdoor unit not received
- FR12 / recall upper lamp 12xIndoor control PCB nonvolatile memory read fault
- PUY-WIRINGMiswiring of indoor/outdoor connecting wire, excessive indoor-unit count, or startup time over
- Starmex 4 blinksIndoor control system
- Starmex 7 blinksOutdoor control system
- Starmex continuous blinkMiswiring or serial signal
Every code is in the full lookup for this brand. Last reviewed 2026-08-21.
Other Mitsubishi Electric Repair Checks
Find the service that matches a different fault on the same brand of aircon.
Frequently Asked Questions
How do you confirm a Mitsubishi Electric PCB fault?
Is a Mitsubishi Electric error code enough to order the PCB?
Should I repair or replace my Mitsubishi Electric aircon?
Ready to Get Started?
Include model and error code or light.