What does Mitsubishi Electric 22 / LED1 13x, LED2 off mean?
Mitsubishi Electric 22 / LED1 13x, LED2 off is listed as outdoor fan motor in Multi-Split rows such as FP Series, Starmex R32. This meaning comes from the manufacturer's own diagnostic material. Confirm the exact model, series, or signal row before accepting a parts quote.
Fan motor locked, slow, not rotating, or outside the expected feedback range.
Fan blade obstruction, worn motor, weak capacitor, or damaged motor harness.
Indoor or outdoor PCB drive fault after the motor and wiring are tested.
What to do now
Use these steps before customer action or a parts quote.
Stop using the unit if 22 / LED1 13x, LED2 off returns
If 22 / LED1 13x, LED2 off remains displayed or returns during operation, do not attempt a reset the manufacturer does not list; arrange diagnosis.
No manufacturer reset steps listed for 22 / LED1 13x, LED2 off
Capture the complete 22 / LED1 13x, LED2 off pattern and model stickers first. The manufacturer lists no customer reset procedure; do not treat a generic power-cycle as manufacturer guidance.
Send these to us
22 / LED1 13x, LED2 off blinking light, a short video of the blinking-light sequence, Mitsubishi Electric model stickers, affected rooms, operating state when the code appeared, and fan noise or no-airflow symptoms
Guidance for your model
Notes that match the code to your exact model. Electrical, refrigerant, wiring, resistance and component checks are for a technician.
| Detail | What it says |
|---|---|
| Diagnostic note | Do not keep resetting the system if this pattern returns. Record the model number, lamp or LED pattern, and affected rooms before booking diagnosis. |
| Singapore / model note | Official Mitsubishi Electric checklist action: Check outdoor fan motor. |
- Detail
- Diagnostic note
- What it says
- Do not keep resetting the system if this pattern returns. Record the model number, lamp or LED pattern, and affected rooms before booking diagnosis.
- Detail
- Singapore / model note
- What it says
- Official Mitsubishi Electric checklist action: Check outdoor fan motor.
What to check before repair
Use this split to separate safe evidence capture from the tests a technician should prove before quoting parts.
| You can check | Technician should confirm |
|---|---|
| Before taking any system action on 22 / LED1 13x, LED2 off, take a short video of the blinking-light sequence. | Confirm whether 22 / LED1 13x, LED2 off points to the indoor fan, outdoor fan, or drive circuit. |
| Capture the Mitsubishi Electric indoor and outdoor model stickers so the correct family row is used. | Check for blade obstruction, motor winding, feedback signal, and connector condition. |
| The manufacturer lists no customer reset procedure for this code. Note whether one room, several rooms, or the whole system is affected. | Confirm PCB fan-drive output before quoting a motor or board. |
- You can check
- Before taking any system action on 22 / LED1 13x, LED2 off, take a short video of the blinking-light sequence.
- Technician should confirm
- Confirm whether 22 / LED1 13x, LED2 off points to the indoor fan, outdoor fan, or drive circuit.
- You can check
- Capture the Mitsubishi Electric indoor and outdoor model stickers so the correct family row is used.
- Technician should confirm
- Check for blade obstruction, motor winding, feedback signal, and connector condition.
- You can check
- The manufacturer lists no customer reset procedure for this code. Note whether one room, several rooms, or the whole system is affected.
- Technician should confirm
- Confirm PCB fan-drive output before quoting a motor or board.
What changes the next step
These clues decide whether the first check is room-side, shared outdoor-side, refrigerant-side, listed-meaning, or model-family confirmation.
| What you see | What it points to |
|---|---|
| Only one indoor unit shows 22 / LED1 13x, LED2 off. | The affected room, indoor board path, wiring route, or local component should be checked first. |
| Several rooms or the outdoor unit show the same 22 / LED1 13x, LED2 off fault. | Prioritise the affected fan, motor feedback, drive circuit, and shared board output. |
| The fan starts slowly, stops, or makes abnormal noise. | Motor feedback, blade obstruction, and board output need to be separated. |
| The model family is different from the row you found online. | Use the model or series filter first; same-looking codes can still belong to different diagnostic tables. |
| The model belongs to Multi-Split rows such as FP Series, Starmex R32. | This meaning comes from the manufacturer's own diagnostic material. Match the code to your model's listing before parts are quoted. |
- What you see
- Only one indoor unit shows 22 / LED1 13x, LED2 off.
- What it points to
- The affected room, indoor board path, wiring route, or local component should be checked first.
- What you see
- Several rooms or the outdoor unit show the same 22 / LED1 13x, LED2 off fault.
- What it points to
- Prioritise the affected fan, motor feedback, drive circuit, and shared board output.
- What you see
- The fan starts slowly, stops, or makes abnormal noise.
- What it points to
- Motor feedback, blade obstruction, and board output need to be separated.
- What you see
- The model family is different from the row you found online.
- What it points to
- Use the model or series filter first; same-looking codes can still belong to different diagnostic tables.
- What you see
- The model belongs to Multi-Split rows such as FP Series, Starmex R32.
- What it points to
- This meaning comes from the manufacturer's own diagnostic material. Match the code to your model's listing before parts are quoted.
Motor or board decision
Mitsubishi Electric 22 / LED1 13x, LED2 off is repair-first when the motor, blade, or feedback circuit is confirmed. Replacement becomes relevant only if motor or board cost is poor value for the system age.
Obstruction or loose connectors are simpler than a failed motor or board output.
Motor replacement depends on whether feedback and winding tests confirm failure.
Board replacement should follow motor and harness checks, not replace them.
Mitsubishi Electric 22 / LED1 13x, LED2 off questions
What does the Mitsubishi Electric 22 / LED1 13x, LED2 off error mean?
Can I fix a Mitsubishi Electric 22 / LED1 13x, LED2 off error myself?
Is it safe to keep running the aircon with a 22 / LED1 13x, LED2 off error?
What causes a Mitsubishi Electric 22 / LED1 13x, LED2 off error?
Will a Mitsubishi Electric 22 / LED1 13x, LED2 off error need a repair or a full replacement?
What should I send a technician about a Mitsubishi Electric 22 / LED1 13x, LED2 off error?
Where to go next
Confirm the fault
Share the error code, model number and symptoms so we can assess the likely cause.
Not the right code?
Browse the full Mitsubishi Electric list or check a few codes in the same fault category.
Read next
Use these if the quote mentions the parts, checks, or repair path this code points to.