York Aircon LP Error Code & Blinking Light

York LP means indoor unit and outdoor unit do not match. If LP stays on or returns, do not reset it.

What it means
Indoor unit and outdoor unit do not match.
Is it serious?
Yes. York LP is a high-severity configuration error. Have it diagnosed before relying on the unit.
Can I keep running it?
If LP stays on or returns, do not reset it. The manufacturer lists no reset; arrange diagnosis. The manufacturer's fault list gives no homeowner fix for LP, so leave it for diagnosis.
Is it worth repairing?
Whether York LP is worth repairing depends on the unit's age, the part that has failed, and that repair's cost against a new unit. For this fault type the part is usually in a setting, address or wiring configuration. A setting or address fault is corrected, not repaired, once the configuration is checked. The code names the fault, not the failed part, so measure before you decide on LP.York by age, from our York page:
York repair-or-replace guidance by system age
System ageUsual call
Under 5 yearsRepair.
5-8 yearsRepair is still cost-effective.
8-12 yearsThe decision depends on the fault and the part supply.
Over 12 yearsPart supply decides.
What it costs to find out
An on-site check in Singapore costs $30 and finds what is causing York LP before any repair is quoted. The fee is waived if you go ahead with the quoted work. Rates as of 20 Nov 2026, on our Pricing page.
On this page

What Does York LP Mean?

York LP is listed as indoor unit and outdoor unit do not match in Inverter Split, Multi-Split entries such as York P Series 9K-12K 115V wall-mounted ductless. This meaning comes from the manufacturer's own diagnostic material. Confirm the exact model and series before accepting a parts quote.

What Causes York LP?

York's fault list for York P Series 9K-12K 115V wall-mounted ductless gives the meaning of York LP but not its causes. These are typical for this fault type, not listed for LP.

  • Indoor and outdoor unit capacity, jumper, model, or platform mismatch.

  • Incorrect setting after installation, PCB change, or mixed-system work.

  • Communication or board configuration issue if the setting is correct but the fault returns.

What Does a Technician Check for York LP?

Before quoting parts for York LP, a technician should confirm the exact model pairing behind LP.

  • Check jumper caps, capacity settings, paired indoor/outdoor model compatibility, and recent board changes.

  • Only quote parts after configuration and communication checks are ruled out.

  • Detail
    Diagnostic note
    What it says
    Verify indoor/outdoor pairing and installed model numbers before changing boards.
  • Detail
    Singapore / model note
    What it says
    YorkNow / Johnson Controls P Series technical-guide entry. Use for the listed P Series 9K-12K 115V wall-mounted ductless family, not as a Singapore YHFF fault-code table.

Will York LP Need a Repair or a New Unit?

York LP is usually corrected by matching settings, model pairing or board configuration. Parts are quoted only after the setup is confirmed.

York LP Questions

What does the York LP error code mean?
York LP means indoor unit and outdoor unit do not match, according to York's fault list for York P Series 9K-12K 115V wall-mounted ductless. The code names the fault the unit has detected, not the failed part. A technician confirms which part is at fault by measurement before quoting a repair.
Is it safe to keep running an aircon showing York LP?
Treat York LP as a fault to diagnose, not a display to clear. If LP stays on or returns, do not reset it. The manufacturer lists no reset; arrange diagnosis. Note the LP display and when it appeared. A technician then confirms the cause of LP by measurement.
What causes York LP?
York's fault list for York P Series 9K-12K 115V wall-mounted ductless gives the meaning of York LP but not its causes. Typical causes for this fault type are indoor and outdoor unit capacity, jumper, model, or platform mismatch; incorrect setting after installation, PCB change, or mixed-system work.
Is York LP worth repairing?
Whether York LP is worth repairing depends on the unit's age, the part that has failed, and that repair's cost against a new unit. For this fault type the part is usually in a setting, address or wiring configuration. A setting or address fault is corrected, not repaired, once the configuration is checked.
How much does it cost to find out what is causing York LP in Singapore?
An on-site check in Singapore costs $30 and finds what is causing York LP before any repair is quoted. The fee is waived if you go ahead with the quoted work. Rates as of 20 Nov 2026, on our Pricing page.